5005369 AIR SILENCER Assy EVINRUDE
E135FCXSDE, E135FCXSNF, E135FCXSOB, E135FCXSRM, E135FCXSTA, E135FPLSDE, E135FPLSOB, E135FPLSRM, E135FPLSTA, E135FPLSTF, E135FPXSDE, E135FPXSOB, E135FPXSRM, E135FSLSDE, E135FSLSTA, E135FSLSTF, E150FCXSDR, E150FCXSNF, E150FCXSOC, E150FCXSRS, E150FCXSTD
AIR
Price: query
Rating:
Compatible models:
E135FCXSDE
E135FCXSNF
E135FCXSOB
E135FCXSRM
E135FCXSTA
E135FPLSDE
E135FPLSOB
E135FPLSRM
E135FPLSTA
E135FPLSTF
E135FPXSDE
E135FPXSOB
E135FPXSRM
E135FSLSDE
E135FSLSTA
E135FSLSTF
E150FCXSDR
E150FCXSNF
E150FCXSOC
E150FCXSRS
E150FCXSTD
E150FHLSDR
E150FHLSOC
E150FHLSRS
E150FPLSDR
E150FPLSOC
E150FPLSRS
E150FPLSTD
E150FPLSTF
E150FPXSDR
E150FPXSOC
E150FPXSRS
E150FSLSDR
E150FSLSTF
E175FCXSDS
E175FCXSNF
E175FCXSOD
E175FCXSRE
E175FCXSTB
E175FPLSDS
E175FPLSOD
E175FPLSRE
E175FPLSTB
E175FPLSTF
E175FPXSDS
E175FPXSOD
E175FPXSRE
E175FSLSDD
E175FSLSTF
E175MFXSOS
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- INTAKE MANIFOLD » 5005369
E135FCXSOB 2004,2005
E135FCXSRM 2004
E135FCXSTA 2003
E135FPLSDE 2006
E135FPLSOB, E135FSLSOB 2004,2005
E135FPLSRM, E135FSLSRM 2004
E135FPLSTA, E135FPXSTA 2003
E135FPLSTF 2003
E135FPXSDE 2006
E135FPXSOB 2004,2005
E135FPXSRM 2004
E135FSLSDE 2006
E135FSLSTA 2003
E135FSLSTF 2003
E150FCXSDR 2006
E150FCXSNF, E150FPLSNF, E150FPXSNF 2002
E150FCXSOC 2004,2005
E150FCXSRS 2004
E150FCXSTD 2003
E150FHLSDR 2006
E150FHLSOC 2004,2005
E150FHLSRS 2004
E150FPLSDR 2006
E150FPLSOC, E150FSLSOC 2004,2005
E150FPLSRS, E150FSLSRS 2004
E150FPLSTD, E150FPXSTD, E150FSLSTD 2003
E150FPLSTF 2003
E150FPXSDR 2006
E150FPXSOC 2004,2005
E150FPXSRS 2004
E150FSLSDR 2006
E150FSLSTF 2003
E175FCXSDS 2006
E175FCXSNF, E175FPLSNF, E175FPXSNF 2002
E175FCXSOD 2004,2005
E175FCXSRE 2004
E175FCXSTB 2003
E175FPLSDS 2006
E175FPLSOD, E175FSLSOE 2004,2005
E175FPLSRE, E175FSLSRB 2004
E175FPLSTB, E175FPXSTB, E175FSLSTM 2003
E175FPLSTF 2003
E175FPXSDS 2006
E175FPXSOD 2004,2005
E175FPXSRE 2004
E175FSLSDD 2006
E175FSLSTF 2003
E175MFXSOS 2005
E175MFXSOS 2004
Information:
Table 1
Revision History
Revision Summary of Changes
14 Changes throughout the document. This special instruction includes the recommended methods for verifying and measuring fuel dilution, and troubleshooting for sources of fuel dilution of the engine oil.Before you perform any procedure in this Special Instruction, read the information and understand the information that is contained in this instruction.Safety
Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Ensure that any tool, procedure, work method, or operating technique you use that is not recommended by Caterpillar is safe.Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage.
Personal injury or death can result from improper maintenance procedures. To avoid injury or death, follow the procedures exactly as stated below.
Required Tools
Table 2
Required Tools
Qty Part Number Part Name
1 1U-5566 Ultraviolet Lamp Gp
1 1U-5575 Additive
19 L (5 US gal) - Container for Fuel
1 164-3310
or
164-3320
or
166-9030 Infrared Thermometer Gp Verifying and Measuring Fuel Dilution
Always determine fuel dilution by analyzing combination of low oil viscosity and percent of fuel in oil. The flash test does not accurately detect fuel dilution. Perform the two tests listed below to verify fuel dilution:
Oil Viscosity Test at 100° C (212° F)
Percent fuel content using Gas Chromatograph Fuel Dilution TestNote: Both the tests should be performed to analyze and compare the result for verifying fuel dilution.Fuel in oil in excess of 6% is required before troubleshooting fuel dilution.If a gas chromatograph dilution test cannot be performed at the dealership, an oil sample can be submitted to a Caterpillar regional SOS Service lab for analysis.Note: Low viscosity does not necessarily mean fuel dilution.Refer to Table 3 for minimum viscosity by oil grade.
Table 3
Viscosity Grade Step 1 Step 2 Step 3
Oil Viscosity at 100° C (212° F) Fuel Dilution as Measured by Gas Chromatograph Action
0W-40 Less than 11.0 cSt Greater than 6% If conditions in Step 1 AND Step 2 are both met, investigate the cause of fuel dilution or reduce the engine oil change interval.
Refer to Section "Troubleshooting for Sources of Fuel Dilution".
5W-40
10W-40
15W-40
0W-30 Less than 8.0 cSt Greater than 6%
5W-30
10W-30 Troubleshooting for Sources of Fuel Dilution
The following troubleshooting procedures can be performed to find the source of fuel dilution:Note: Caterpillar recommends performing these procedure one after the other and record the values to help further troubleshooting, if required.
Duty cycle of the Engine/Machine
Fuel system
Oil qualityDuty Cycle of the Engine/Machine
For engines operating normally, the machine application or the duty cycle may be contributing to unacceptable fuel dilution.
Engines with higher idle time
Engines with higher fuel and ambient temperatures
Engines that run cold
Engines operating under light loadsUse the following procedure to determine the cause:
Verify the fuel dilution by low viscosity and gas chromatograph fuel dilution test. The fuel dilution percent must be equal to or greater than 6%. Refer to Table 3 for minimum viscosity by oil grade.
Initially, reduce the engine oil change interval by 50 hours. Submit oil samples for evaluation at one half of the new interval and at the time of the new interval.
If the reduced interval produces acceptable results from the oil analysis, continue operation with the same interval.
If viscosity and fuel dilution are still unacceptable, reduce the service by another 50 hours. Evaluate the results from each oil sample. Refer to Step 2.
Continue the above process until acceptable results for gas chromatograph fuel dilution test and oil viscosity are obtained.Investigating Fuel System Leaks
Use the following procedure to determine the locations or sources of fuel dilution around the electronic unit injectors under the valve cover.The required tools are listed below:
1U-5566 Ultraviolet Lamp Gp
1U-5575 Additive
19 L (5 US gal) container fo