0581453 EVINRUDE ARMATURE PLATE AND POST


0581453 ARMATURE PLATE AND POST EVINRUDE E3BRCEC, E3BRESR, E4BRCICI, E4BRHCCS, E4BRHCDE, E4BRHCNR, E4BRHCOB, E4BRHCRM, E4BRHCTA, E4BRHCUD, E4WCIC, E4WCNR ARMATURE
0581453 ARMATURE PLATE AND POST EVINRUDE
Rating:
8

Buy ARMATURE PLATE AND POST 0581453 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$83.99

01-09-2024
1.0[0.45] pounds
US: LEADERS RPM
Johnson Evinrude OMC New OEM Armature Plate & Post Assembly, 0581453
Johnson Evinrude OMC SKU: 0581453 || Sold Each || Please verify your own fitment || Superseded From: 0580121
Number on catalog scheme: 30
 

BRP EVINRUDE entire parts catalog list:

E3BRCEC 1989
E3BRESR 1990
E4BRCICI, E4BRLCIC 1981
E4BRHCCS, E4BRHLCCS 1988
E4BRHCDE, E4BRHLCDE 1986
E4BRHCNR, E4BRHLCNR 1982
E4BRHCOB, E4BRHLCOB 1985
E4BRHCRM, E4BRHLCRM 1984
E4BRHCTA, E4BRHLCTA 1983
E4BRHCUD, E4BRHLCUD 1987
E4WCIC 1981
E4WCNR 1982

Information:

Probable Causes
The following probable causes apply if the generator is equipped with the EMCP II+:
There is an incorrect calibration value for the AC Transformer Box + (ATB+).
A potential transformer in the ATB+ is faulty.
A current transformer in the ATB+ is faulty.
The ATB+ is faulty.
There is an incorrect value for one or more of the parameters for the fuel.
There is an incorrect value for one or more of the "Power Monitoring" parameters.The following probable causes apply if the generator is equipped with a power sensor:
There is a faulty potential transformer for the power sensor.
There is a faulty current transformer for the power sensor.
The power sensor is faulty.
There is a problem with the wiring between the power sensor and the ECM.
There is an incorrect value for one or more of the parameters for the fuel.
The offset voltage from the power sensor is too high.
There is an incorrect value for one or more of the "Power Monitoring" parameters.Read the rest of this procedure before you adjust the "Power Monitoring" parameters.Recommended Repairs
Generators that are Equipped with EMCP II+
Verify that the transformers and the ATB+ are operating correctly. Refer to the appropriate service literature for the EMCP II+.Verify that the values for the "Air/Fuel Ratio Control" configuration parameters are correct. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Verify that the values for the "Power Monitoring" configuration parameters are correct. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Generators that are Equipped with a Power Sensor
Verify that the transformers for the power sensor are operating correctly. Refer to the service literature for the power sensor.Verify that the power sensor is operating correctly. Refer to the service literature for the power sensor.Verify that the values for the "Air/Fuel Ratio Control" configuration parameters are correct. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Check the wiring between the power sensor and the ECM for corrosion and for pinch points. Refer to Troubleshooting, "Electrical Connectors - Inspect".The control system must receive an accurate voltage from the power sensor. When the generator's output is zero, the voltage from the power sensor must be less than 0.01 VDC. This voltage is called the offset voltage.Use the following procedure in order to determine if the offset voltage is too high. Perform this procedure before you adjust the "Power Monitoring" parameters.Note: The engine must be stopped. If the engine is equipped with an ASM, take the measurement at the P5 connector. If the engine is not equipped with an ASM, take the measurement at the P1 connector.
If the engine is running, stop the engine.
Insert 7X-1710 Multimeter Probes into terminals P1-19 and P1-25 or into P1-3 and P1-16. Connect a digital voltmeter to the probes. The polarity of the connections is not important.
Verify that the probes are making good contact with the terminals inside the connector. Measure the DC voltage at the terminals. The voltage is acceptable if the voltage is less than 0.01 VDC.If the voltage is less than 0.01 VDC, the values for the "Power Monitoring" parameters may be incorrect. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".If the voltage is greater than 0.01 VDC, the circuit between the power sensor and the ECM must be calibrated. Refer to Troubleshooting, "Generator Output Power Sensor - Set".


Parts armature EVINRUDE:

0581999
 
0581999 ARMATURE PLATE ASSEMBLY
E4BRCICI, E4BRHCNR, E4BRHCRM, E4BRHCTA, E4WCIC, E4WCNR
0582958
 
0582958 ARMATURE PLATE ASSEMBLY
E4BRHCDE, E4BRHCOB, E4BRHCUD
0583292
 
0583292 ARMATURE PLATE ASSEMBLY
E3BRCEC, E3BRESR, E4BRHCCS
Back to top