0318444 BELLCRANK, Choke EVINRUDE
18304A, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25904R, 35602G, E25CNE, E25ECIB, E25ECTD, E25RCSA, E25RSA, E25RSLS, E35ECIG, E35ECND, E35ECSM, E35ECTS
BELLCRANK
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
- CARBURETOR » 0318444
25402M, 25403M, 25452M, 25453M 1974
25502B, 25503B, 25552B, 25553B 1975
25602E, 25603E, 25652E, 25653E 1976
25702H, 25702S, 25703H, 25703S, 25752H, 25752S, 25753H, 25753S, 35702C, 35702H, 35703C, 35703H, 35752C, 35752H, 35753C, 35753H 1977
25802C, 25803C, 25852C, 25853C, 35802R, 35803R, 35852R, 35853R 1978
25904R, 25905R, 25952R, 25953R, 35902A, 35903A, 35952A, 35953A 1979
35602G, 35602S, 35603G, 35603S, 35652G, 35652S, 35653G, 35653S 1976
E25CNE, E25ELCNE, E25RCNB, E25RLCNB, E25TECNB, E25TELCNB 1982
E25ECIB, E25ECIM, E25ELCIB, E25ELCIM, E25RCIM, E25RLCIM, E25TECIM, E25TELCIM 1981
E25ECTD, E25ELCTD, E25RCTE, E25RLCTE, E25TECTE, E25TELCTE 1983
E25RCSA, E25RLCSA, E25TECSA, E25TELCSA 1980
E25RSA, E25RSLA, E25RWCIM, E25RWLCIM 1981
E25RSLS, E25RSS, E25RWCTE, E25RWLCTE 1983
E35ECIG, E35ELCG, E35ELCIG, E35RCIG, E35RLCIG 1981
E35ECND, E35ELCND, E35RCND, E35RLCND, E35TELCNB 1982
E35ECSM, E35ELCSM, E35TCSM, E35TLESM 1980
E35ECTS, E35ELCTS, E35RCTS, E35RLCTS, E35TELCTS 1983
Information:
Illustration 1 g00515355
Upper Display With SP Fault Code SP1 Showing
Illustration 2 g00478451
System Schematic For Spare Fault InputsA spare fault informs the operator of an undesirable condition (fault) that exists. The spare inputs are programmed into the GSC to meet the requirements of the customer or application. An active spare input causes an alarm fault or a shutdown fault. For programming of the spare inputs, see Systems Operation, "Spare Input/Output Programming OP6". The programmer (customer, operator, or service personnel) is responsible for noting the actual conditions that cause a SP fault code. The GSC does not diagnose the spare inputs and spare faults are not recorded in the fault log.The GSC treats an active input state as a fault. The active state is programmable on the GSC to be either a high or a low (factory default) voltage level. A high level is within the range of +5 DCV to the positive battery. If the input is left floating (for example an open switch), the GSC pulls the input voltage up to 10.5 DCV and the input is treated as high level. A low level on the input is B- (ground).When a spare fault occurs (active), the GSC determines the type of fault (alarm or shutdown). The GSC also FLASHES the corresponding fault alarm indicator or fault shutdown indicator. For a shutdown type of fault, the SP fault code is immediately shown on the upper display. For an alarm type of fault, the alarm code key is pressed first. Then the SP fault code is shown on the upper display. After a spare fault is corrected or is not present, the SP fault code is no longer shown on the upper display.
Table 1
Spare Fault Codes    
Spare Fault Code    GSC Connector Contact    Terminal Strip    Related Setpoints (1)    
SP1 Spare Fault 1     23     SP1     SP01, SP02, SP08    
SP2 Spare Fault 2     24     SP2     SP03, SP04, SP09    
SP3 Spare Fault 3     25     SP3     SP05, SP06, SP10    
( 1 ) See Spare Input/Output Programming OP6 within the topic Service Mode in the Systems Operation section.SP fault codes are associated with the spare inputs. The SP fault code that is shown on the upper display, identifies the spare input that caused the alarm fault or shutdown fault. The spare inputs are accessed on the terminal strip within the control panel on the rear wall.When a SP fault code is showing on the upper display, check the programming notes in order to determine the cause.The spare fault inputs can be used with options that are installed by the factory and/or the customer. The following list contains the factory options for the spare fault inputs:
ground fault
low fuel level
high fuel level
high generator winding temperature
high generator bearing temperatureEach of these options will include a dedicated indicator and a label on the custom alarm module.Troubleshooting Procedure
To troubleshoot spare faults, use this general procedure.
Check for obvious causes that are related to the device that is responsible for the spare fault.
Verify that the programming of the spare fault (alarm or shutdown) is appropriate for the application.
Check the function of the responsible device. Reset the fault by turning the ECS to the OFF/RESET position. Verify that the fault is still present.
Disconnect the device that is responsible from the spare fault input. Verify that the fault still exists.
Check the wiring to the corresponding spare fault input for an unwanted short to either battery negative (B-) or battery positive (B+).
Parts bellcrank EVINRUDE:
0319695
0319695 BELLCRANK
25702H, 25802C, 25904R, 35602G, B25JREUR, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25ARECA, BE25AREDC, BE25AREUR, BE25BAECM, BE25BAEDR, BE25EECE, BE25EEDM, BE25EEUB, BE30BAECS, BE30BAEDE, BE30BAEEC, BE30BAEUD, BE30BASIA, BE
0327687