5030026 BOLT, Rod, stern bracket EVINRUDE
E5RECS
BOLT
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$16.81
14-09-2017
1.00[0.45] pounds
Auto 7: Auto 7
Auto 7 503-0026 Engine Oil Pressure Switch
Original equipment quality parts for Hyundai, KIA and GM Daewoo vehicles without the original equipment price||All parts manufactured in South Korea, the same place the Korean cars they fit are manufactured||All parts meet strict quality standards to ensure the correct fit and function the first time||Over 70,000 parts available making virtually every part required to repair your vehicle available||12 month/12,000 mile warranty
Original equipment quality parts for Hyundai, KIA and GM Daewoo vehicles without the original equipment price||All parts manufactured in South Korea, the same place the Korean cars they fit are manufactured||All parts meet strict quality standards to ensure the correct fit and function the first time||Over 70,000 parts available making virtually every part required to repair your vehicle available||12 month/12,000 mile warranty
Compatible models:
E5RECS
EVINRUDE
BRP EVINRUDE entire parts catalog list:
Information:
Personal injury can result from contact with refrigerant.This system is under pressure at all times, engine running or not. Heat should never be applied to a charged system. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel either away from the machine or where they can be seen.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Open the left engine guard.
Illustration 1 g00818937
Remove oil filters (1).
Illustration 2 g00818938
Cut cable ties (4).
Remove bolts (3).
Remove oil pan plate (2).
Illustration 3 g00818949
Loosen nut (6), nut (6A), and bolt (7).
Move V-Belt (5) aside.
Illustration 4 g00818951
Remove bolt (8), the nut, and washers.
Remove bolt (9), washers, and the spacer.
Remove rod (10).
Disconnect connector (11).
Illustration 5 g00818959
Disconnect hose assemblies (12) and (13).
Illustration 6 g00818960
Remove nut (15), bolt (16), and washers.
Remove refrigerant compressor (14). Installation Procedure
Personal injury can result from contact with refrigerant.This system is under pressure at all times, engine running or not. Heat should never be applied to a charged system. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel either away from the machine or where they can be seen.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Note: Check the O-ring seals, the gaskets, and the seals for wear or for damage. Replace the components, if necessary.
Illustration 7
Parts bolt EVINRUDE:
5031050
5031038
5031046
5031046 BOLT
E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E5RECS
5030003
5030002
5030002 BOLT, Cylinder & crankcase
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS, E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E5RECS, E70, E70FLTLECS, E70PL4EEC, E70PL4SIA
5030030
5030029
5030041