0305100 BUSHING, Steering handle EVINRUDE
18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 35602G, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 50202C, 50302R, 6002B, 6102E, 6202D, 6302S, 6402C, 6504R, 6604A, 6
BUSHING
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
TOP PLATE LOW RIDE - REPLACES PETERBILT 03-05100 03-07678
World American World American
World American World American
NAILZON for Ariens 0305100 Fixed Hoc Clip NOS
NAILZON For Ariens 0305100 Fixed Hoc Clip NOS || Fixed Hoc Clip eres secure and stable connection for equipment, part number 0305100 NOS. || NOS Fixed Hoc Clip is desied for -lasting perforce and durability on equipment. || Lawn perfection starts with our precision-made replacement parts. || Prior to confirming your order, we strongly recommend verifying the product's appearance in the photo and its dimensions to avoid any potential discrepancies.
NAILZON For Ariens 0305100 Fixed Hoc Clip NOS || Fixed Hoc Clip eres secure and stable connection for equipment, part number 0305100 NOS. || NOS Fixed Hoc Clip is desied for -lasting perforce and durability on equipment. || Lawn perfection starts with our precision-made replacement parts. || Prior to confirming your order, we strongly recommend verifying the product's appearance in the photo and its dimensions to avoid any potential discrepancies.
Compatible models:
BRP EVINRUDE entire parts catalog list:
- LOWER UNIT GROUP » 0305100
18202R, 18203R 1972
18304A, 18305A 1973
18802A, 18802E, 18802M, 18803A, 18803E, 18803M 1968
18902B, 18902D, 18903B, 18903D 1969
25002C, 25002E, 25003C, 25003E 1970
25102S, 25103S 1971
25202R, 25203R, 25252R, 25253R 1972
25302A, 25303A, 25352A, 25353A 1973
25402M, 25403M, 25452M, 25453M 1974
25502B, 25503B, 25552B, 25553B 1975
25602E, 25603E, 25652E, 25653E 1976
25702H, 25702S, 25703H, 25703S, 25752H, 25752S, 25753H, 25753S, 35702C, 35702H, 35703C, 35703H, 35752C, 35752H, 35753C, 35753H 1977
25802C, 25803C, 25852C, 25853C, 35802R, 35803R, 35852R, 35853R 1978
25902B, 25902D, 25903B, 25903D 1969
35602G, 35602S, 35603G, 35603S, 35652G, 35652S, 35653G, 35653S 1976
40102B, 40102G, 40103B, 40103G, 40152B, 40152G, 40153B, 40153G 1971
40202E, 40203E, 40252E, 40253E 1972
40304D, 40305D, 40354D, 40355D 1973
40404S, 40405S, 40454S, 40455S 1974
40504C, 40505C, 40554C, 40555C 1975
40604A, 40604R, 40605A, 40605R, 40654A, 40654R, 40655A, 40655R 1976
50202C, 50203C, 50272C, 50273C 1972
50302R, 50303R, 50372R, 50373R 1973
6002B, 6003B 1970
6102E, 6102G, 6103E, 6103G 1971
6202D, 6203D 1972
6302S, 6303S 1973
6402C, 6403C 1974
6504R, 6505R 1975
6604A, 6605A 1976
6704M, 6705M 1977
6802A, 6802C, 6802R, 6803A, 6803C, 6803R 1968
6804B, 6805B 1978
6902M, 6903M 1969
9022A, 9022C, 9023A, 9023C 1970
9122R, 9123R 1971
9222M, 9223M 1972
9322B, 9323B 1973
9822D, 9822E, 9823D, 9823E 1968
9922S, 9923S 1969
Information:
Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
E265(3) User Defined Shutdown The inputs from the ground level shutdown switch to the Electronic Control Module (ECM) have changed states. The engine will shut down. The code is logged.
267-2 Remote Shutdown Input erratic, intermittent, or incorrect Both of the switch contacts for the ground level shutdown switch are in the open state or both of the switch contacts for the ground level shutdown switch are in the closed state. If both of the switch contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged. The ground level shutdown switch provides the ability to shut down the engine from outside of the operator compartment. To shut down the engine, lift the red cover guard and toggle the ground level shutdown switch to the SHUTDOWN position. The engine ECM remains active after the ground level shutdown has been activated. The ECM reads the position of the ground level shutdown switch. If the engine is running, the ECM disables the fuel injection. After the activation of the ground level shutdown switch, the switch must be returned to the RUN position and the engine rpm must be zero before the ECM will allow the engine to start.Caterpillar Electronic Technician (ET) can be used to check the status of the ground level shutdown switch. The status screen will display "INJECTION DISABLED" and "Remote Shutdown". The ECM will not allow the engine to start while Cat ET reports that the status for the ground level shutdown switch is "Shutdown On".
Illustration 1 g01337443
Schematic for the ground level shutdown switch
Test Step 1. INSPECT THE ELECTRICAL CONNECTORS AND THE WIRING
Turn the keyswitch to the OFF position.
Illustration 2 g01337445
Location of the ECM connectors and the machine connectors for the ground level shutdown switch
(1) J1/P1 ECM connectors
(2) Machine connectors (25-pin)
Illustration 3 g01337444
Location of the ground level switch (typical left side view)
(3) Ground level shutdown switch
Thoroughly inspect connectors (1) and (2). Also, thoroughly inspect the connectors for ground level shutdown switch (3). Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 4 g01337494
Terminal locations at the P1 ECM connector for the ground level shutdown switch
(P1-23) Ground level shutdown (NC)
(P1-40) Ground level shutdown (NO)
Illustration 5 g01337496
Terminal locations at the machine connector (25-pin) for the ground level shutdown switch
(Terminal 8) Ground level shutdown (NO)
(Terminal 10) Ground level shutdown (NC)
Illustration 6 g01337514
Terminal locations at the connector for the ground level shutdown switch
(Terminal 1) Ground level shutdown (NO)
(Terminal 2) Chassis ground
(Terminal 3) Ground level shutdown (NC)
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the ground level shutdown switch. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the allen head screw for each of the ECM connectors for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
Check the harness and the wiring for abrasion and for pinch points. Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The connectors and the wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the repair eliminates the problem.STOPTest Step 2. USE CAT ET TO CHECK THE STATUS OF THE SHUTDOWN SWITCH
Connect Cat ET to the service tool connector.
Turn the keyswitch to the ON position. Start Cat ET.
While you operate the switch, observe the status of the "Shutdown Switch" on Cat ET. Note: Wait at least 30 seconds in order for the status of the switch to change on Cat ET.Expected Result:The correct status of the "Shutdown Switch" is "Shutdown On" when the switch is in the SHUTDOWN position. The correct status is "Shutdown Off" when the switch is in the RUN position.Results:
OK - Cat ET reports "Shutdown On" when the switch is in the SHUTDOWN position. Cat ET reports "Shutdown Off" when the switch is in the RUN position.Repair: The ground level shutdown switch is operating correctly. There may be an intermittent problem in the harness or in a connector. If an intermittent problem is suspected, refer to Troubleshooting, "Electrical Connectors - Inspect" for information that is related to troubleshooting the problem.STOP
Not OK - Either of the following results occur: Cat ET does not report "Shutdown On" when the switch is in the SHUTDOWN position. Cat ET does not report "Shutdown Off" when the switch is in the RUN position. The ground level shutdown switch is not operating correctly. Proceed to Test Step 3.Test Step 3. INSTALL A JUMPER WIRE AT THE CONNECTOR FOR THE GROUND LEVEL SHUTDOWN SWITCH
Turn the keyswitch to the OFF position.
Disconnect the connector for the ground level shutdown switch.
Fabricate a jumper wire that is long enough to create a short circuit between two terminals at the connector for the ground level shutdown switch. Crimp connector pins to each end of the jumper wire.
Install the jumper wire between terminal 1 and terminal 2 at the connector for the ground level shutdown switch.
Turn the keyswitch to the ON position.
Observe
Parts bushing EVINRUDE:
0308532
0308532 BUSHING,Throttle lever
100193A, 100293R, 100882B, 100990S, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 40072A, 40202E, 40304D, 40404S, 40504C, 4060
0303279
0303947
0303997
0303997 BUSHING, Reverse gear
18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 25904R, E25CNE, E25ECIB, E25ECRS, E25ECTD, E25RCSA, E25RSA, E25RSLS, E25RWCDC, E25RWCOS, E25RWCRD, E25RWCUR, E25RWEDC, E25
0304765
0304765 BUSHING, Shift rod
10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 15404G, 15504C, 15604A, 18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 25904R, 33002M, 33802M, 33902A, 40002A, 40052A, 40
0309513
0309513 BUSHING, Spindle
33002M, 33802M, 33902A, 40002A, 40052A, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 40802A, 40852A, 40902R, 40952R, E40RSLR, E40RWCDB, E40RWCOM, E40RWCRA
0312708
0312708 BUSHING,Starter
100990S, 115890C, 150940C, 3802A, 4006E, 4106D, 4206S, 4306C, 4406R, 4506A, 4606M, 4706B, 4806E, 4902B, 50202C, 50302R, 50442M, 50542B, 50902C, 55642E, 55772D, 55874S, 65372R, 70442M, 70572B, 70673D, 70773S, 70873C, 75542B, 75642D, BE130TLECE, BE130T
0303140
0303140 BUSHING,Throttle control
6002B, 6102E, 6202D, 6302S, 6402C, 6504R, 6604A, 6704M, 6802A, 6804B, 6902M, 6904E