0382559 EVINRUDE CABLE ASSY.,Instruments


0382559 CABLE ASSY.,Instruments EVINRUDE 100882B, 85892A CABLE
0382559 CABLE ASSY.,Instruments EVINRUDE
Rating:
43

Buy CABLE ASSY.,Instruments 0382559 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 31
 

Compatible models:

100882B   85892A   EVINRUDE

BRP EVINRUDE entire parts catalog list:

100882B, 100883B 1968
85892A, 85893A 1968

Information:


Table 1
Diagnostic Codes Table    
Code and Description    Conditions which Generate this Code    System Response    
94-3 Fuel Delivery Pressure Sensor voltage above normal     The Electronic Control Module (ECM) detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
500 kPa (75 psi).    
94-4 Fuel Delivery Pressure Sensor voltage below normal     The Electronic Control Module (ECM) detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
500 kPa (75 psi).    
100-3 Engine Oil Pressure Sensor voltage above normal     The Electronic Control Module (ECM) detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
500 kPa (75 psi).    
100-4 Engine Oil Pressure Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    
110-3 Engine Coolant Temperature Sensor voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
−40 °C (−40 °F).    
110-4 Engine Coolant Temperature Sensor voltage below normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
−40 °C (−40 °F).    
164-0 Injector Actuation Pressure high - most severe (3)     The ECM detects injection actuation pressure that is above
24 MPa (3481 psi) for one second.
The ECM has been powered for three seconds.     The code is logged.
The fuel limit is set to a predetermined value.    
164-3 Injector Actuation Pressure voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
12 MPa (1741 psi).
The current to the IAPCV is set to 0.23 Amp.
The fuel limit is set to a predetermined value.    
164-4 Injector Actuation Pressure voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.
This diagnostic code indicates the ECM may be faulty     The code is logged.
The value of the parameter is set to a pressure of
12 MPa (1741 psi).    
174-3 Fuel Temperature Sensor voltage above normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
30 °C (86 °F).    
174-4 Fuel Temperature Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
30 °C (86 °F).    
175-3 Engine Oil Temperature Sensor voltage above normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
90 °C (194 °F).    
175-4 Engine Oil Temperature Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
90 °C (194 °F).    
273-0 Turbocharger Outlet Pressure Sensor high - most severe (3)     The ECM detects turbocharger outlet pressure is above normal for five seconds.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
0.0 kPa (0.0 psi).    
273-3 Turbocharger Outlet Pressure Sensor voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
0.0 kPa (0.0 psi).    
273-4 Turbocharger Outlet Pressure Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
0.0 kPa (0.0 psi).    
274-3 Atmospheric Pressure Sensor voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.     The code is logged.
The value of the parameter is set to a pressure of
45 kPa (7 psi).    
274-4 Atmospheric Pressure Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    System OperationUse this procedure to troubleshoot any suspect problems with the following pressure sensors:
Engine oil pressure sensor
Atmospheric pressure sensor
Turbocharger outlet pressure sensor
Injection actuation pressure sensorThe ECM performs an automatic calibration of these sensors whenever the ECM is powered and the engine is off for at least five seconds. During an automatic calibration, the ECM calibrates pressure sensors to the value of the atmospheric pressure sensor and against an acceptable offset pressure range.Use this procedure to troubleshoot any suspect problems with the following temperature sensors:
Engine oil temperature sensor
Fuel temperature sensor
Coolant temperature sensorThe supply voltage is routed to terminal A of each sensor connector. The sensor return is routed to terminal B of each sensor connector. The sensor signal is routed to terminal C of each sensor connector. The ECM provides short circuit protection for the internal power supply. A short circuit to


Parts cable EVINRUDE:

0381440
CABLE,Rev.lock release
0381440 CABLE,Rev.lock release
100882B, 65832B, 85852A, 85892A
0380956
 
0380956 CABLE ASSEMBLY
100882B, 40872A, 85892A
0383033
0377369
CABLE,Throttle,9'
0377369 CABLE,Throttle,9'
100882B, 115983E, 40072A, 40872A, 40972R, 55872A, 55972A, 85892A, 85993E
0377376
 
0377376 CABLE,Throttle,16'
100193A, 100293R, 100882B, 115083D, 115983E, 125183C, 125283R, 40072A, 40872A, 40972R, 50172S, 50202C, 55872A, 55972A, 60072B, 60172C, 65272S, 85093B, 85193A, 85293R, 85892A, 85993E
0376936
 
0376936 CABLE,Throttle,6'
100882B, 40872A, 55872A, 85892A
0377372
CABLE,Throttle,12'
0377372 CABLE,Throttle,12'
100193A, 100293R, 100882B, 115083D, 115983E, 125183C, 125283R, 40072A, 40872A, 40972R, 50172S, 50202C, 55872A, 55972A, 60072B, 60172C, 65272S, 85093B, 85193A, 85293R, 85892A, 85993E
0377378
 
0377378 CABLE,Throttle,18'
100193A, 100293R, 100882B, 115083D, 115983E, 125183C, 125283R, 40072A, 40872A, 40972R, 50172S, 50202C, 55872A, 55972A, 60072B, 60172C, 65272S, 85093B, 85193A, 85293R, 85892A
Back to top