0583207 EVINRUDE CABLE ASSY., Switch & gauge


0583207 CABLE ASSY., Switch & gauge EVINRUDE BE50DTLEDC, BE60ELEDR, BE70ELEDA, C155WTLM, CE275TLCDC, CE300TLCDC, E115ELEOC, E125WTPLE, E130CXAOR, E150CXCCA, E150CXCEM, E150CXESB, E150ELEOM, E150TLCDC, E150TLCUR, E150WTLEOR, E155WTLCDR, E155WTLCUA, E155WTLEIB, E155WTLENE, E155WTLESM, E155WTLZ, E CABLE
0583207 CABLE ASSY., Switch & gauge EVINRUDE
Rating:
13

Buy CABLE ASSY., Switch & gauge 0583207 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$74.96
 

15-01-2019
200 Hundredths Pounds
Evinrude J: Evinrude Johnson OMC
Evinrude/Johnson/OMC Trim & Tilt 33' ft Wire Harness Extension Cable 583207 New
SKU: 0583207 || Sold Each || Please verify your own fitment
Number on catalog scheme: 13
 

BRP EVINRUDE entire parts catalog list:

BE50DTLEDC, E50DTLEDC, E50ELED 1996
BE60ELEDR, BE60TLEDR, E60ELEDR, E60TLEDR 1996
BE70ELEDA, BE70TLEDA, E70TLEDA, HE70TXEDA 1996
C155WTLM, C155WTXM 1988
CE275TLCDC, CE275TXCDC, E275PTLCDC, E275PTXCDC 1986
CE300TLCDC, CE300TXCDC, E300TLCDC, E300TXCDC 1986
E115ELEOC, E115GLEOC, E115SLEOC, E115SXEOC, L115GLEOS 1995
E125WTPLE 1995
E130CXAOR, E130TLEOA, E130TXAOR 1995
E150CXCCA, E150TLCCA, E150TXCCA 1988
E150CXCEM, E150TLCEM, E150TXCEM, TE150TXCEM 1989
E150CXESB, E150TLESB, E150TXESB, VE150TLESB, VE150TXESB 1990
E150ELEOM, E150EXEOM, E150GLEOM, E150JLEOM, E150NXEOM, E150SLEOM, L150GLEOS, VE150HLEOS 1995
E150TLCDC, E150TXCDC 1986
E150TLCUR, E150TXCUR 1987
E150WTLEOR, E150WTXEOR 1995
E155WTLCDR, E155WTXCDR 1986
E155WTLCUA, E155WTXCUA 1987
E155WTLEIB, E155WTXEIB 1991
E155WTLENE, E155WTXENE 1992
E155WTLESM, E155WTXESM 1990
E155WTLZ, E155WTXZ 1989
E175EXEOM, E175GLEOM, E175NXEOM, E175SLEOM 1995
E175STLCCM, E175TLCCM, E175TXCCM 1988
E175STLCEB, E175TXCEB 1989
E175STLESE, E175TXESE, VE175SLESE, VE175TXESE 1990
E175TLCDR, E175TXCDR 1986
E175TLCUA, E175TXCUA 1987
E185ESXENR 1992
E185ESXESS 1990
E185ESXETA, E185ESXETF 1993
E185ESXW 1989
E200CXATF, E200CXATS, E200CXETD, E200CXETF, E200CZATF, E200CZATS, E200CZETD, E200CZETF, E200STLETC, E200STLETF, E200TXATF, E200TXATS, E200TXETD, E200TXETF, E200TZATF, E200TZATS, E200TZETD, E200TZETF, VE200SLETC, VE200SLETF, VE200TXETD, VE200TXETF, VE200TZETD, VE200TZETF 1993
E200CXCCR, E200STLCCM, E200TXCCR 1988
E200CXCEA, E200STLCEB, E200TXCEA, TE200TXCEA 1989
E200CXEIB, E200STLEID, E200TXEIB, VE200SLEID, VE200TXEIB 1991
E200CXENE, E200STLENS, E200TXENE, VE200SLENS, VE200TXENE 1992
E200CXESM, E200STLESE, E200TXESM, VE200SLESE, VE200TXESM 1990
E200STLCDR, E200TXCDS 1986
E200STLCUA, E200TXCUC 1987
E225CLCUB, E225CXCUB, E225PLCUB, E225PXCUB, E225TLCUB, E225TXCUB 1987
E225CXATF, E225CXATS, E225CXETA, E225CXETF, E225CZATF, E225CZATS, E225CZETA, E225CZETF, E225PLETA, E225PLETF, E225PXATF, E225PXATS, E225PXETA, E225PXETF, E225PZATF, E225PZATS, E225PZETA, E225PZETF, E225STLETF, E225TLETA, E225TLETF, E225TXATF, E225TXATS, E225TXETA, E225TXETF, E225TZATF, E225TZATS, E225TZETA, E225TZETF, VE225PLETA, VE225PLETF, VE225PXETA, VE225PXETF, VE225PZETA, VE225PZETF, VE225STLETF, VE225TLETA, VE225TLETF, VE225TXETA, VE225TXETF, VE225TZETA, VE225TZETF 1993
E225CXCCE, E225PLCCE, E225PXCCE, E225TLCCE, E225TXCCE 1988
E225CXCED, E225PLCED, E225PXCED, E225TLCED, E225TXCED 1989
E225CXEIC, E225PLEIC, E225PXEIC, E225TLEIC, E225TXEIC, VE225PLEIC, VE225PXEIC, VE225TLEIC, VE225TXEIC 1991
E225CXENR, E225PLENR, E225PXENR, E225TLENR, E225TXENR, VE225PLENR, VE225PXENR, VE225TLENR, VE225TXENR 1992
E225CXESS, E225PLESS, E225PXESS, E225TLESS, E225TXESS, VE225PLESS, VE225PXESS, VE225TLESS, VE225TXESS 1990
E225PTLCDA, E225PTXCDA, E225TLCDA, E225TXCDA 1986
E250CXATF, E250CXATS, E250CXETF, E250CXETS, E250CZATF, E250CZATS, E250CZETF, E250CZETS, E250TXATF, E250TXATS, E250TXETF, E250TXETS, E250TZATF, E250TZATS, E250TZETF, E250TZETS 1993
E250CXEIE, E250TXEIE 1991
E250CXEND, E250CZEND, E250TXEND, E250TZEND 1992
E275CLCUR, E275CXCUR, E275PLCUR, E275PXCUR 1987
E275CXCCA, E275PLCCA, E275PXCCA 1988
E300CLCUR, E300CXCUR, E300PLCUR, E300PXCUR 1987
E300CXCCA, E300PLCCA, E300PXCCA 1988
E300CXCEM, E300PLCEM, E300PXCEM 1989
E300CXEIE, E300PLEIE, E300PXEIE 1991
E300CXEND, E300PLEND, E300PXEND 1992
E300CXESB, E300PLESB, E300PXESB 1990
E300CXETF, E300CXETS, E300PLETF, E300PLETS, E300PXETF, E300PXETS 1993
E50DTLEOS, E50ELEOS 1995
E60ELEOC, E60TLEOC 1995
E70ELEOR, E70TLEOR 1995
E90ELEOC, E90EXEOC, E90SLEOC 1995

Information:


Table 1
Diagnostic Codes
CDL Code and Description Conditions which Generate this Code System Response
3090-3
Aftertreatment #1 SCR Dosing Reagent Pressure Sensor:Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range. The code is logged.
The value of the parameter is set to a default value.
3090-4
Aftertreatment #1 SCR Dosing Reagent Pressure Sensor:Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged.
The value of the parameter is set to a default value.
3092-3
Aftertreatment #1 SCR Dosing Air Assist Pressure Sensor:Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged.
The value of the parameter is set to a default value.
3092-4
Aftertreatment #1 SCR Dosing Air Assist Pressure Sensor:Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged.
The value of the parameter is set to a default value.
3107-3
Aftertreatment #1 SCR Catalyst Outlet Gas Temperature Sensor:Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged.
The value of the parameter is set to a default value.
3107-4
Aftertreatment #1 SCR Catalyst Outlet Gas Temperature Sensor:Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged.
The value of the parameter is set to a default value. The supply voltage is routed to terminal 1 of each sensor connector. The sensor return is routed to terminal 2 of each sensor connector. For the pressure sensors, the sensor signal is routed to terminal 3 of each sensor connector. The sensor signal for the exhaust temperature sensors is routed to terminals 3 and 4 of the connector for the sensor buffer.The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.Diagnostic Testing using Caterpillar Electronic Technician (ET)Wiggle Test - The wiggle test allows the technician to monitor the status of the signals from the sensors. For additional information regarding the wiggle test, refer to the documentation that accompanies the Cat ET software.
Illustration 1 g03320797
Schematic
Test Step 1. Check for Diagnostic Codes
Connect Caterpillar Electronic Technician (ET) to the service tool connector. Establish a connection with the engine ECM.
Turn the keyswitch to the ON position.
Look for the following codes that are active or logged:
-3
-4Results:
Active -3 Code - A -3 diagnostic code is active. Proceed to Test Step 2.
Active -4 code - A -4 diagnostic code is active. Proceed to Test Step 3.Test Step 2. Create a Short at the Sensor Connector
Use a test lamp in order to create a short between terminal 3 (signal) and terminal 2 (return) at the sensor connector.
Turn the keyswitch to the ON position.
Monitor the diagnostic codes on Cat ET. Check for an active -4 diagnostic code for the suspect sensor.
Turn the keyswitch to the OFF position. Results:
Active -4 - A -4 diagnostic code became active after creating the short at the sensor connector.Repair: The wiring is OK. Replace the sensor.Verify that the problem is resolved.STOP
Active -3 - The -3 diagnostic code remains active for the suspect sensor. Proceed to Test Step 4.Test Step 3. Create an Open at the Suspect Sensor Connector
Turn the keyswitch to the OFF position.
Disconnect the sensor connector of the suspect sensor with the active -4 diagnostic code.
Turn the keyswitch to the ON position.
Monitor the diagnostic codes on Cat ET. Check for an active -3 diagnostic code for the suspect sensor.
Turn the keyswitch to the OFF position. Results:
Active -3 - A -3 diagnostic code became active after disconnecting the sensor.Repair: The wiring is OK. Replace the sensor.Verify that the problem is resolved.STOP
Active -4 - The -4 diagnostic code remains active for the suspect sensor. Proceed to Test Step 4.Test Step 4. Check the 5 V Supply Voltage at the Sensor Connector
Turn the keyswitch to the ON position.
Measure the voltage between pin 1 (analog supply) and pin 2 (analog return). Expected Result:The supply voltage at the sensor connector is 5.0 0.2 VDC.Results:
OK - The supply voltage is approximately 5.0 0.2 VDC. Connect the sensor and then proceed to Test Step 5.
Not OK - The supply voltage is not approximately 5.0 0.2 VDC.Repair: There is a short circuit to battery voltage in the wiring harness. Repair the wiring or replace the harness.Verify that the problem is resolved.STOPTest Step 5. Perform the Wiggle Test on the Suspect HarnessCarefully following this procedure is the best way to identify the root cause of an intermittent problem.
Turn the keyswitch to the ON position.
Use Cat ET to start the wiggle test.
Slowly wiggle the wiring and the connectors between each of the ECM connectors and the sensor. Pay particular attention to the wiring near each connector. Be sure to wiggle all of the wiring. As you wiggle the wiring look for these problems.
Loose connectors or damaged connectors
Moisture on the connectors or the wiring
Damage that is caused by excessive heat
Damage that is caused by chafing
Improper routing of wiring
Damaged insulationExpected Result:Each segment of the wiring harness passed the wiggle test.Results:
OK - The wiring passed the wiggle test.Repair: There may be an intermittent problem in the harness or in a connector. Recheck each segment of the wiring harness. Refer to Troubleshooting, "Electrical Connectors - Inspect" for information that is related to the inspection of wiring and connectors.If the wiring appears to be OK, perform the following procedure:
Turn the keyswitch to the OFF position.
Disconnect the connectors. Carefully inspect the terminals for proper installation. Ensure that each terminal in the connector is clean and dry.
Turn the keyswitch to the OFF position.
Insert a pin into each socket. Verify that each socket grips the pin firmly. Repair any problems.
Connect all connectors.
Verify that the problem is resolved.
Return the unit to service. STOP
Not OK - The wiggle test identified a problem in the harness.Repair: There is a problem with the wiring. Repair the wiring or replace the wiring.Verify that the problem is resolved.STOP


Parts cable EVINRUDE:

0583010
CABLE ASSY., Motor Relay
0583010 CABLE ASSY., Motor Relay
C155WTLM, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E100WMLCDR, E100WMLCOC, E100WTLCUA, E100WTLEIB, E100WTLENE, E100WTLEOC, E100WTLERS, E100WTLESM, E100WTLETD, E100WTLZ, E110MLCCA, E110MLCDC, E110MLCEM, E110M
0397600
 
0397600 CABLE ASSY., Spark advance
CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E200STLCUA, E225CLCUB, E275CLCUR, E300CLCUR
0583205
 
0583205 CABLE ASSY., Switch & gauge
C155WTLM, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E100WMLCDR, E100WTLCUA, E100WTLEIB, E100WTLENE, E100WTLERS, E100WTLESM, E100WTLETD, E100WTLZ, E110MLCCA, E110MLCDC, E110MLCEM, E110MLCUR, E115JLEIE, E115JLE
0583105
 
0583105 CABLE ASSY., Sending unit
C155WTLM, CE275TLCDC, CE300TLCDC, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E100WMLCDR, E100WTLCUA, E100WTLEIB, E100WTLENE, E100WTLEOC, E100WTLERS, E100WTLESM, E100WTLETD, E100WTLZ, E110MLCCA, E110MLCDC, E110
0173581
 
0173581 CABLE MTG. HARDWARE KIT
E120TLCCA, E120TLCEM, E120TLESB, E140CXCCS, E140CXCEC, E140CXESR, E150CXCCA, E150CXCEM, E150CXESB, E175STLCCM, E175STLCEB, E175STLESE, E185ESXESS, E185ESXW, E200CXCCR, E200CXCEA, E200CXESM, E225CXCCE, E225CXCED, E225CXESS, E275CXCCA, E300CXCCA, E300C
0583909
 
0583909 CABLE, Junction box switch
BE130TLECE, BE130TLEDM, BE130TLEUB, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E100WTLEIB, E100WTLENE, E100WTLEOC, E100WTLERS, E100WTLESM, E100WTLETD, E100WTLZ, E110MLCEM, E112TSLEOC, E112TSLEOC, E112TSLERS, E115JKLEOC, E
0583903
 
0583903 CABLE ASSY., Junction box to trim switch
E150CXCEM, E150CXEIE, E150CXESB, E150STLCEM, E150STLEIE, E150STLESB, E155WTLEIB, E155WTLENE, E155WTLESM, E155WTLZ, E175STLCEB, E175STLEID, E175STLESE
0584303
 
0584303 CABLE AY., Tilt limit switch
BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, E100STLEIE, E100STLEND, E100STLERC, E100STLETS, E100WTLEDR, E100WTLEUA, E112TSLEDR, E112TSLEDR, E115JLEIE, E115JLEND, E115JLEOR, E115JLERC, E115JLETS, E115JLEUM, E115TSLECM, E115TSLEUA, E120TLEIE, E120T
Back to top