0391727 EVINRUDE CARB ASSY., Lower 235 only


0391727 CARB ASSY., Lower 235 only EVINRUDE E150TRLCIA, E175TRLCIM, E200TRLCIB, E235TRLCIB CARB
0391727 CARB ASSY., Lower 235 only EVINRUDE
Rating:
18

Buy CARB ASSY., Lower 235 only 0391727 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 39172
 

Compatible models:

BRP EVINRUDE entire parts catalog list:

E150TRLCIA, E150TRLCIH, E150TRXCIA, E150TRXCIH 1981
E175TRLCIM, E175TRXCIH, E175TRXCIM 1981
E200TRLCIB, E200TRLCIH, E200TRXCIB, E200TRXCIH 1981
E235TRLCIB, E235TRLCIH, E235TRXCIB, E235TRXCIH 1981

Information:

System configuration parameters affect the emissions and the power of the engine. Default values for the parameters are programmed at the factory. Some parameters may be changed by the customer in order to suit the needs of the specific application.Parameter Descriptions
Equipment ID
"Equipment ID" allows the customer to enter a description into the ECM in order to identify the machine. A maximum of 17 characters may be entered in the field. This parameter is only for reference by the customer. This parameter is not required.Engine Serial Number
Program the "Engine Serial Number" to match the engine serial number that is stamped on the engine information plate. The engine serial number is not preprogrammed on a replacement ECM.ECM Serial Number
The serial number of the ECM that is stored in the ECM memoryPersonality Module Group Part Number
The part number of the flash file that is currently installed in the ECMPersonality Module Description
The description of the application for the flash file that is currently installed in the ECMPersonality Module Release Date
The release date of the flash file that is currently installed in the ECMFLS (Full Load Setting)
"FLS" is a number that represents the adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information plate. Factory passwords are required in order to change this parameter.FTS (Full Torque Setting)
"FTS" is similar to "FLS". Factory passwords are required in order to change this parameter.Idle Shutdown Time
This parameter allows the operator to adjust the delay for engine shutdown.Shutdown Timer
The idle shutdown timer allows the engine to continue running after the keyswitch is turned to the OFF position.Lighting Shutdown Timer Enable Status
This parameter allows a set of lights on the tractor to remain illuminated after the keyswitch is turned to the OFF position.Lighting Shutdown Timer Duration
This parameter allows the operator to adjust the delay for lighting shutdown.Deceleration Pedal Installation Status
The parameters for the deceleration pedal allow the deceleration pedal to be "Installed" or "Not Installed". The parameters for the deceleration pedal also allow the adjustment of minimum engine speed that can be obtained with the deceleration pedal.Max Deceleration Pedal Pos Eng Spd
This parameter is configured in order to set the engine speed when the deceleration pedal is in the maximum decelerated position. The deceleration pedal will regulate the engine speed between this engine speed and the engine speed that is currently set by the lever that is for the high idle throttle position.Ground Speed Radar Installation Status
This parameter allows a sensor for the ground speed radar to be "Installed" or "Not Installed" on the application.Product Sales Model
Program this parameter to the sales model that is for the engine application.Machine System Protection Strategy Installation Status
This parameter allows the engine ECM to be configured for the installation of a machine security system. The parameter can be configured as "Installed" or "Not Installed" on the application.System Configuration Parameters
Table 2
System Configuration Parameters    
Parameter    Available Range or Options    Default    Required Password    
Configuration Group 1    
"Equipment ID"     17 alphanumeric characters     Not Programmed     None    
Engine Serial Number     0XX00000 or XXX00000     0XX00000     None    
ECM Serial Number     Read Only (1)    
Personality Module Part Number     Software Dependent     Read Only (1)    
Personality Module Description     Software Dependent     Read Only (1)    
Personality Module Release Date     Software Dependent     Read Only (1)    
FLS (Full Load Setting)     - 128 to 127     1     Factory    
FTS (Full Torque Setting)     - 128 to 127     −1     Factory    
Idle Shutdown Time     0 to 20 minutes     0 minutes     None    
Shutdown Timer     Enabled
Disabled     Disabled     None    
Lighting Shutdown Timer Enable Status     Enabled
Disabled     Disabled     None    
Lighting Shutdown Timer Duration     0 to 20 minutes     0 minutes     None    
Decelerator Pedal Installation Status     Not Installed
Installed     Not Installed     None    
Max Deceleration Pedal Pos Eng Sp


Parts carb EVINRUDE:

0390401
CARB ASSY.,Lower 150 only
0390401 CARB ASSY.,Lower 150 only
E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM
0390402
 
0390402 CARB ASSY.,Middle 150 only
E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM
0390404
 
0390404 CARB ASSY.,Lower 175 only
E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM
0390405
 
0390405 CARB ASSY.,Middle 175 only
E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM
0390410
 
0390410 CARB ASSY.,Upper 235 only
E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM
0390411
 
0390411 CARB ASSY.,Middle 235 only
E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM
0391728
 
0391728 CARB ASSY., Middle 235 only
E150TRLCIA, E175TRLCIM, E200TRLCIB, E235TRLCIB
0392130
 
0392130 CARB ASSY., Lower 200 only
E150TRLCIA, E175TRLCIM, E200TRLCIB, E235TRLCIB
Back to top