Typical schematicTest Step 1. Check for an Open Circuit in the OFF/RESET position.
If equipped, disconnect the remote start/stop initiate contacts from the terminal strip in the Generator Terminal box.
Disconnect the harness connector from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Turn the ECS to the OFF/RESET position.
At the GSC+ harness connector, measure the resistance from contact "39" to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "39" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - All resistance measurements are correct. Proceed to test step 2.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after troubleshooting is complete.STOPTest Step 2. Check for an Open Circuit in the AUTO position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the AUTO position. Measure the resistance from contact "40" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "39" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "40" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "39" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 3.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 3. Check for an Open Circuit in the MAN/START position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the MAN/START position. Measure the resistance from contact "33" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "39" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "33" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "39" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 4.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 4. Check for an Open Circuit in the COOLDOWN/STOP position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Parts clamp EVINRUDE:
5030135
5030135 CLAMP
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS, E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E5RECS, E70, E70FLTLECS, E70PL4EEC, E70PL4SIA
5030580
5030580 CLAMP
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS, E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E70, E70FLTLECS, E70PL4EEC, E70PL4SIA
5030576
5030576 CLAMP
E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E70, E70FLTLECS, E70PL4EEC, E70PL4SIA
5030815
5031280
5031280 CLAMP, Large
E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E70
5031278
5031278 CLAMP
E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E70, E70PL4SIA
5032620
5032612