0345753 EVINRUDE CONNECTOR, Throttle shaft


0345753 CONNECTOR, Throttle shaft EVINRUDE E200FCSSSC, E200FCXEEN, E200FPLSSC, E200FPXSSC, E225FCXEEN, E225FCXSSC, E225FGLSSC, E225FHLSSS, E225FPXSSC, E250FCXSSS, E250FGLSSS, E250FPXSSS CONNECTOR
0345753 CONNECTOR, Throttle shaft EVINRUDE
Rating:
83

Buy CONNECTOR, Throttle shaft 0345753 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 30
 

BRP EVINRUDE entire parts catalog list:

E200FCSSSC, E200FCSSSH, E200FCXSSC, E200FCXSSH 2000
E200FCXEEN, E200FCXEES, E200FPLEEN, E200FPLEES, E200FPXEEN, E200FPXEES, E200FSLEEN, E200FSLEES 1999
E200FPLSSC, E200FPLSSH, E200FSLSSC, E200FSLSSH, RE200FLSSC, RE200FLSSH, RE200FSSH 2000
E200FPXSSC, E200FPXSSH, RE200FXSSC, RE200FXSSH 2000
E225FCXEEN, E225FCXEEO, E225FCXEES, E225FCZEEN, E225FCZEEO, E225FCZEES, E225FPLEEN, E225FPLEEO, E225FPLEES, E225FPXEEN, E225FPXEEO, E225FPXEES, E225FPZEEN, E225FPZEEO, E225FPZEES 1999
E225FCXSSC, E225FCXSSH, E225FCZSSC, E225FCZSSH, RE225FCSSC, RE225FCSSH 2000
E225FGLSSC, E225FGLSSH, E225FPLSSC, E225FPLSSH, RE225FGSSC, RE225FGSSH, RE225FLSSC, RE225FLSSH 2000
E225FHLSSS, RE225FHSSS 2000
E225FPXSSC, E225FPXSSH, E225FPZSSC, E225FPZSSH, RE225FXSSC, RE225FXSSH, RE225FZSSH 2000
E250FCXSSS, E250FCZSSS 2000
E250FGLSSS, E250FPLSSS 2000
E250FPXSSS, E250FPZSSS 2000

Information:

Active Event Codes
An active event code represents a problem with engine operation. Correct the problem as soon as possible.Active event codes are listed in ascending numerical order. The code with the lowest number is listed first.Illustration 1 is an example of the operating range of a temperature sensor. Do not use the Illustration to troubleshoot temperature sensors.
Illustration 1 g01138880
Example of the typical operating range of a temperature sensor
(1) This area represents the normal operating range of the parameter. The normal output voltage of the sensor is between 0.2 VDC and 4.2 VDC.
(2) In this area, the temperature above 107 °C (225 °F) is higher than normal. The output voltage of the sensor will generate an event code. The sensor does not have an electronic problem.
(3) In these areas, the output voltage of the sensor is too high or too low. The voltage is outside of the normal range. The electronic problem will generate a diagnostic code. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code" for additional information on diagnostic codes. Events are represented in two formats. In the first format, the "E" identifies the code as an event code. The "XXX" represents a numeric identifier for the event code. This is followed by a description of the code. If a warning, a derate, or a shutdown is applicable, the numeric identifiers are different. Refer to the following example:
E004 Engine Overspeed ShutdownIn the second format, the "E" identifies the code as an event code. The "XXX-X" represents a numeric identifier for the event code. The fourth "X" identifies the event as a warning, a derate, or a shutdown. This is followed by a description of the code. Refer to the following example:
E360-1 Low Oil Pressure Warning
E360-2 Low Oil Pressure Derate
E360-3 Low Oil Pressure ShutdownThe definition for a warning, a derate, and a shutdown are defined below:Warning - This condition represents a serious problem with engine operation. However, this condition does not require a derate or a shutdown.Derate - For this condition, the Electronic Control Module (ECM) reduces the engine's power in order to help prevent possible engine damage.Shutdown - For this condition, the ECM shuts down the engine in order to help prevent possible engine damage.Logged Event Codes
When the ECM generates an event code the ECM logs the code in permanent memory. The ECM has an internal diagnostic clock. The ECM will record the following information when an event code is generated:
The hour of the first occurrence of the code
The hour of the last occurrence of the code
The number of occurrences of the codeLogged events are listed in chronological order. The most recent event code is listed first.This information can be helpful for troubleshooting intermittent problems. Logged codes can also be used to review the performance of the engine.Clearing Event Codes
A code is cleared from memory when one of the following conditions occur:
The code does not recur for 100 hours.
A new code is logged and there are already ten codes in memory. In this case, the oldest code is cleared.
The service technician manually clears the code.Always clear logged event codes after investigating and correcting the problem which generated the code.Troubleshooting
For basic troubleshooting of the engine, perform the following steps in order to diagnose a malfunction:
Obtain the following information about the complaint:
Determine the time that the event occurred.
Determine the conditions for the event. The conditions will include the engine rpm and the load.
Determine if there are any systems that were installed by the dealer or by the customer that could cause the event.
Determine whether any additional events occurred.
Verify that the complaint is not due to normal engine operation. Verify that the complaint is not due to error of the operator.
Narrow the probable cause. Consider the operator information, the conditions of operation, and the history of the engine.
Perform a visual inspection. Inspect the following items:
Fuel supply
Oil level
Oil supply
Wiring
ConnectorsBe sure to check the connectors. This is very important for problems that are intermittent. Refer to Troubleshooting, "Electrical Connectors - Inspect".If these steps do not resolve the problem, identify the procedures in this manual that best describe the event. Check each probable cause according to the tests that are recommended.Trip Points for the Monitoring System
The monitoring system determines the level of action that is taken by the ECM in response to a condition that can damage the engine. When any of these conditions occur, the appropriate event code will trip.Table 1 contains the conditions that are monitored and the default trip points for each condition. Each condition has an associated parameter. The settings for each parameter can be viewed with the Caterpillar Electronic Technician (ET). The trip points for some of the parameters may be adjustable with Cat ET.
Table 1
Monitoring System Parameters
Parameter Action Delay Time in Seconds Trip Point Default State
Min Max Default Min Max Default
E096-1 High Fuel Pressure Warning N/A N/A 8 N/A N/A 758 kPa (110 psi) On
E172-1 High Air Filter Restriction Warning N/A N/A software dependent N/A N/A 8 kPa (1 psi) On
E172-2 High Air Filter Restriction Derate (1) N/A N/A software dependent N/A N/A 8 kPa (1 psi) On
E194 High Exhaust Temperature Derate N/A N/A N/A N/A N/A Software dependent On
E265 User Defined Shutdown Shutdown N/A N/A N/A N/A N/A On/Off
E360-1 Low Engine Oil Pressure Warning N/A N/A 8 N/A N/A Map dependent value(2).


Parts connector EVINRUDE:

0511866
 
0511866 . CONNECTOR
BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100FPLSOC, E100FPLSRS, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E100WMLCDR, E100WMLCOC, E100WMLCRS,
0513357
CONNECTOR
0513357 CONNECTOR
BE10FAEDC, BE10FAEUR, BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE175EXECD, BE175EXEDB, BE175EXEUC, BE
0513356
CONNECTOR
0513356 CONNECTOR
BE10FAEDC, BE10FAEUR, BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE175EXECD, BE175EXEDB, BE175EXEUC, BE
0513663
CONNECTOR
0513663 CONNECTOR
BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR,
3010124
 
3010124 CONNECTOR, 2-pin, air temp.
E100FPLSOC, E100FPLSRS, E115DBXSUC, E115DPLSUC, E115DPXSUC, E115DSLSUC, E115FPLEEC, E115FPLSDS, E115FPLSIF, E115FPLSNF, E115FPLSOD, E115FPLSRE, E115FPLSSH, E115FPLSTB, E115FPXSDS, E115FPXSOD, E115FPXSRE, E115FSLECS, E115FSLSDS, E135FCXSDE, E135FCXSIF
3010049
CONNECTOR, Motor not serviced
3010049 CONNECTOR, Motor not serviced
DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, DE150PXINS, DE200CXAAA, DE200CXAAC, DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200PXAAA, DE200PXAAC, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA
0514591
 
0514591 CONNECTOR, TPS
E100FPLSOC, E100FPLSRS, E115FPLEEC, E115FPLSDS, E115FPLSIF, E115FPLSNF, E115FPLSOD, E115FPLSRE, E115FPLSSH, E115FPLSTB, E115FPXSDS, E115FPXSOD, E115FPXSRE, E115FSLECS, E115FSLSDS, E135FCXSDE, E135FCXSIF, E135FCXSNF, E135FCXSOB, E135FCXSRM, E135FCXSSS
3010593
 
3010593 CONNECTOR, 2-pin
E200FCSSSC, E200FCXEEN, E200FCXSIF, E200FCXSNF, E200FCXSOE, E200FCXSRB, E200FCXSTM, E200FHLSOR, E200FHLSRC, E200FPLSNF, E200FPLSOE, E200FPLSRB, E200FPLSSC, E200FPLSTM, E200FPXSSC, E225FCXEEN, E225FCXSIF, E225FCXSNF, E225FCXSOE, E225FCXSRB, E225FCXSSC
Back to top