0587053 EVINRUDE *CONNECTOR & SEAL Assy


0587053 *CONNECTOR & SEAL Assy EVINRUDE DE250CXISF, DE250PXISF, DE300CXISF, DE300PXISF, E200DHLSEB, E200DHXSEA, E200HCXSEA, E200HSLSEA, E225DCXISE, E225DCXSEB, E225DHLISE, E225DHLSEB, E225DPLISE, E225DPLSEB, E225DPXISE, E225DPXSEB, E225HSLISF, E225HSLSEC, E250DCXISE, E250DCXSEB, E250DHLSEC CONNECTOR
0587053 *CONNECTOR & SEAL Assy EVINRUDE
Rating:
18

Buy *CONNECTOR & SEAL Assy 0587053 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 80
 

BRP EVINRUDE entire parts catalog list:

DE250CXISF, DE250CXISS, DE250CZISF, DE250CZISS 2010
DE250PXISF, DE250PXISS, DE250PZISF, DE250PZISS 2010
DE300CXISF, DE300CXISG, DE300CXISS, DE300CZISF, DE300CZISG, DE300CZISS 2010
DE300PXISF, DE300PXISG, DE300PXISS, DE300PZISF, DE300PZISG, DE300PZISS 2010
E200DHLSEB 2009
E200DHXSEA, E200HVLSEC 2009
E200HCXSEA 2009
E200HSLSEA 2009
E225DCXISE, E225DCXISF, E225DCZISE, E225DCZISF 2010
E225DCXSEB, E225DCZSEB 2009
E225DHLISE, E225DHLISF, E225DHXISB, E225DHXISF 2010
E225DHLSEB, E225DHXSEM 2009
E225DPLISE, E225DPLISF 2010
E225DPLSEB 2009
E225DPXISE, E225DPXISF, E225DPZISE, E225DPZISF 2010
E225DPXSEB, E225DPZSEB 2009
E225HSLISF, E225HSLISR 2010
E225HSLSEC 2009
E250DCXISE, E250DCXISF, E250DCZISE, E250DCZISF 2010
E250DCXSEB, E250DCZSEB 2009
E250DHLSEC, E250DHXSEC 2009
E250DPLISE, E250DPLISF 2010
E250DPLSEB 2009
E250DPXISE, E250DPXISF, E250DPZISE, E250DPZISF 2010
E250DPXSEB, E250DPZSEB 2009
E250HGLSES, E250HGXSES 2009
E250HSLSES 2009
E300DCXISF, E300DCXISG, E300DCXISR, E300DCZISF, E300DCZISG, E300DCZISR 2010
E300DCXSEC, E300DCZSEC 2009
E300DPXISF, E300DPXISG, E300DPXISR, E300DPZISF, E300DPZISG, E300DPZISR, E300DSLISC, E300DSLISF, E300DSLISG 2010
E300DPXSEC, E300DPZSEC, E300DSLSES 2009

Information:


Always determine the cause of shutdown, and have the necessary repairs made before restarting the engine.Emergency shutoff controls are for emergency use only. Do not use an emergency shutoff device for a normal stopping procedure.
Electric Shutoff Controls
The operation of all electric shutoff controls is similar: A critical operating condition actuates a switch in the sensing unit. The switch closes the circuit to the shutoff solenoid which moves linkage to bypass the fuel to the cylinders; thus stopping the engine. The shutoff control may require resetting before the engine can start.High Water Temperature Shutoff:
The shutoff switch is located in the water temperature regulator housing. Excessive water temperature closes the switch. No resetting procedure is required: As the coolant cools, the switch opens.
The sensing element must be submerged in the coolant to operate. A low coolant level cannot actuate the shutoff.
Low Oil Pressure Shutoff Switch:
This device is usually mounted on the side of the engine with oil lines connected to the switch. Low oil pressure closes the switch. Manually operated systems require resetting of this switch before starting. Automatic start-stop systems use a pressure switch which resets itself.To reset the switch, push the button until it latches. After the engine starts and develops oil pressure, the oil pressure will push the button to the extended running position.
The engine will not be protected if the engine is operated with the button latched in the START position.
If the button remains in the reset position, the engine oil pump is not developing normal oil pressure and a check should be made.Overspeed Shutoff Switch (Electro-Mechanical):
This switch is mounted either on the tachometer drive or on the governor. Excessive engine speed closes a switch by centrifugal force.
TWO INSTALLATIONS OF OVERSPEED SWITCHTo reset the switch, push the button marked RESET. The knob will remain down until the engine overspeeds.Overspeed Shutoff Switch (Electronic):
This switch is a magnetic pick-up which is mounted on the flywheel housing and senses engine speed. The control box is mounted on the engine block. Excessive engine speed closes a circuit breaker. To reset the switch, push arm of breaker to the run position.
This switch will not provide overspeed protection if there is no power to the control box.
Fuel/Oil Pressure Switch:
This switch is mounted in the fuel manifold between the clean side of the fuel filter and the fuel injection pump housing. Low fuel pressure (below 3 psi) opens the switch and the electrical circuit to either the shut off solenoid or the circuit between the alternator and the alternator regulator. Opening of these circuits prevents the battery from becoming discharged while the engine is stopped. This switch can also be used with an electric governor. In this application, oil pressure closes the switch to allow the electric governor to control engine speed.
This switch does not require resetting.Mechanical Safety Shutoff Control
The mechanical safety shutoff is both a low oil pressure and an overspeed shutoff device. A high water temperature shutoff can be installed which uses the low oil pressure shutoff device to stop the engine.On 6 cylinder engines, the mechanical shutoff is mounted on the side of the engine. On vee engines, the shutoff is mounted in the vee of the engine between the two banks of cylinders. The high water temperature shutoff is installed in the temperature regulator housing of all engines.If an overspeed, low oil pressure, or high water condition occurs, a spring loaded rod is mechanically tripped internally, which moves and holds the rack in the shutoff position.Difficult starting with long periods of cranking can trip the low oil pressure shutoff. The reset lever must be moved and latched in the run position before starting can be accomplished. Normal stopping of the engine will not trip the shutoff device. The basic cause for the shutdown can be determined by the manner in which the shutoff must be reset:1. Push the reset lever (or handle). If the rod latches, an overspeed condition stopped the engine. Investigate the cause for overspeed condition. If the rod does not latch, the engine was stopped because of a low oil supply to the shutoff control. This could be caused by either low engine oil pressure, or by the high water temperature shutoff bypassing the oil to the mechanical shutoff. Therefore, perform checks for both low oil supply and high water temperature. Reset the control by the following steps:1. Push the reset button firmly. 2. Push the reset lever (or handle) until the rod latches.If the reset lever does not move freely, check the reset cable for kinks, binds, or lack of lubrication. Make needed repairs or adjustments.Air Safety Shutoff Control
The air shutoff control is an attachment to the mechanical safety shutoff device installed on large bore vee type engines. When an emergency condition occurs, the mechanical shutoff pushes the rack into the shutoff position and pulls a butterfly valve, located in each inlet manifold, to the closed position. The air safety shutoff control must be reset before starting. If an overspeed condition shut the engine down:1. Pull the air shutoff reset lever on the air inlet manifold to the RESET position. 2. Release the lever. The lever should move slightly and then latch in the RUN position.3. Push the mechanical shutoff reset lever until the rod latches. If a low oil pressure or high water temperature condition shut the engine down:1. Firmly push the reset button in the vee of the engine. 2. Pull the air shutoff reset handle on the air inlet manifold to the RESET position. 3. Release the lever. The lever should move slightly and latch in the RUN position.4. Push the mechanical shutoff reset lever until the rod latches. Hydraulic Shutoff Controls
The hydraulic shutoff control is mounted on (or near) the gov


Parts connector EVINRUDE:

0513663
CONNECTOR
0513663 CONNECTOR
BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR,
0513664
CONNECTOR, Motor
0513664 CONNECTOR, Motor
BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR,
0514687
 
0514687 CONNECTOR, 6-plug
BE10EEDD, BE10FAEDC, BE10FAEUR, BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE10RELEUS, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15EEDS, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE15RE
3011153
*CONNECTOR & SEAL, 2 Position plug
3011153 *CONNECTOR & SEAL, 2 Position plug
DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, DE150PXINS, DE200CXAAA, DE200CXAAC, DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200PXAAA, DE200PXAAC, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA
3011155
*CONNECTOR & SEAL, 3 Position plug
3011155 *CONNECTOR & SEAL, 3 Position plug
DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, DE150PXINS, DE200CXAAA, DE200CXAAC, DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200PXAAA, DE200PXAAC, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA
3011156
*CONNECTOR, 6 Position cap
3011156 *CONNECTOR, 6 Position cap
DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, DE150PXINS, DE200CXAAA, DE200CXAAC, DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200PXAAA, DE200PXAAC, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA
3011392
*CONNECTOR
3011392 *CONNECTOR
DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, DE150PXINS, DE200CXAAA, DE200CXAAC, DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200PXAAA, DE200PXAAC, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA
3011267
 
3011267 *CONNECTOR, 5 Position cap
DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, DE150PXINS, DE200CXAAA, DE200CXAAC, DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200PXAAA, DE200PXAAC, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA
Back to top