0354578 EVINRUDE *COVER, Impeller housing


0354578 *COVER, Impeller housing EVINRUDE DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD, DE250PXISF COVER
0354578 *COVER, Impeller housing EVINRUDE
Rating:
98

Buy *COVER, Impeller housing 0354578 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 87
 

BRP EVINRUDE entire parts catalog list:

DE200HXAAA, DE200HXAAB 2012
DE200HXAAC 2012
DE200HXAAD 2012
DE200XCAAA, DE200XCAAB 2012
DE200XCAAC 2012
DE200XCAAD 2012
DE225CXAAA, DE225CXAAB 2012
DE225CXAAC 2012
DE225CXAAD 2012
DE225CXINS 2012
DE225PXAAA, DE225PXAAB 2012
DE225PXAAC 2012
DE225PXAAD 2012
DE250CXAAA, DE250CXAAB, DE250CZAAA, DE250CZAAB 2012
DE250CXAAC, DE250CZAAC 2012
DE250CXAAD, DE250CZAAD 2012
DE250CXISF, DE250CXISS, DE250CZISF, DE250CZISS 2010
DE250PXAAA, DE250PXAAB, DE250PZAAA, DE250PZAAB 2012
DE250PXAAC, DE250PZAAC 2012
DE250PXAAD, DE250PZAAD 2012
DE250PXISF, DE250PXISS, DE250PZISF, DE250PZISS 2010
DE300CXAAA, DE300CXAAB, DE300CZAAA, DE300CZAAB 2012
DE300CXAAC, DE300CZAAC 2012
DE300CXAAD, DE300CZAAD 2012
DE300CXIIC 2011
DE300CXINR, DE300CZINR 2012
DE300CXISF, DE300CXISG, DE300CXISS, DE300CZISF, DE300CZISG, DE300CZISS 2010
DE300CZIIC 2011
DE300PXAAA, DE300PXAAB, DE300PZAAA, DE300PZAAB 2012
DE300PXAAC, DE300PZAAC 2012
DE300PXAAD, DE300PZAAD 2012
DE300PXISF, DE300PXISG, DE300PXISS, DE300PZISF, DE300PZISG, DE300PZISS 2010
E200DHLAAA, E200DHLAAB 2012
E200DHLAAC 2012
E200DHLAAD 2012
E200DHLSEB 2009
E200DHXAAA, E200DHXAAB, E200HSLAAA, E200HSLAAB 2012
E200DHXAAC, E200HSLAAC 2012
E200DHXAAD, E200HSLAAD 2012
E200DHXSEA, E200HVLSEC 2009
E200HCXAAA, E200HCXAAB 2012
E200HCXAAC 2012
E200HCXAAD 2012
E200HCXSEA 2009
E200HSLSEA 2009
E225DCXAAA, E225DCXAAB 2012
E225DCXAAC 2012
E225DCXAAD 2012
E225DCXIID, E225DCZIID 2011
E225DCXINS, E225DCZINS 2012
E225DCXISE, E225DCXISF, E225DCZISE, E225DCZISF 2010
E225DCXSEB, E225DCZSEB 2009
E225DHLAAA, E225DHLAAB, E225DHXAAA, E225DHXAAB 2012
E225DHLAAC, E225DHXAAC 2012
E225DHLAAD, E225DHXAAD 2012
E225DHLISE, E225DHLISF, E225DHXISB, E225DHXISF 2010
E225DHLSEB, E225DHXSEM 2009
E225DPLISE, E225DPLISF 2010
E225DPLSEB 2009
E225DPXAAA, E225DPXAAB, E225HSLAAA, E225HSLAAB 2012
E225DPXAAC, E225HSLAAC 2012
E225DPXAAD, E225HSLAAD 2012
E225DPXISE, E225DPXISF, E225DPZISE, E225DPZISF 2010
E225DPXSEB, E225DPZSEB 2009
E225HSLISF, E225HSLISR 2010
E225HSLSEC 2009
E250DCXAAA, E250DCXAAB, E250DCZAAA, E250DCZAAB 2012
E250DCXAAC, E250DCZAAC 2012
E250DCXAAD, E250DCZAAD 2012
E250DCXISE, E250DCXISF, E250DCZISE, E250DCZISF 2010
E250DCXSEB, E250DCZSEB 2009
E250DHLAAA, E250DHLAAB, E250DHXAAA, E250DHXAAB 2012
E250DHLAAC, E250DHXAAC 2012
E250DHLAAD, E250DHXAAD 2012
E250DHLSEC, E250DHXSEC 2009
E250DPLISE, E250DPLISF 2010
E250DPLSEB 2009
E250DPXAAA, E250DPXAAB, E250DPZAAA, E250DPZAAB 2012
E250DPXAAC, E250DPZAAC 2012
E250DPXAAD, E250DPZAAD 2012
E250DPXISE, E250DPXISF, E250DPZISE, E250DPZISF 2010
E250DPXSEB, E250DPZSEB 2009
E250HGLAAB, E250HGXAAB 2012
E250HGLAAC, E250HGXAAC 2012
E250HGLAAD, E250HGXAAD 2012
E250HGLSES, E250HGXSES 2009
E250HSLAAA, E250HSLAAB 2012
E250HSLAAC 2012
E250HSLAAD 2012
E250HSLSES 2009
E300DCXAAA, E300DCXAAB, E300DCZAAA, E300DCZAAB 2012
E300DCXAAC, E300DCZAAC 2012
E300DCXAAD, E300DCZAAD 2012
E300DCXIIA, E300DCZIIA 2011
E300DCXINM 2012
E300DCXISF, E300DCXISG, E300DCXISR, E300DCZISF, E300DCZISG, E300DCZISR 2010
E300DCXSEC, E300DCZSEC 2009
E300DCZINM 2012
E300DPXAAA, E300DPXAAB, E300DPZAAA, E300DPZAAB, E300DSLAAA, E300DSLAAB 2012
E300DPXAAC, E300DPZAAC, E300DSLAAC 2012
E300DPXAAD, E300DPZAAD, E300DSLAAD 2012
E300DPXISF, E300DPXISG, E300DPXISR, E300DPZISF, E300DPZISG, E300DPZISR, E300DSLISC, E300DSLISF, E300DSLISG 2010
E300DPXSEC, E300DPZSEC, E300DSLSES 2009

Information:

Phase Rotation
The phase rotation must be the same. A set of three light bulbs is used to determine whether the phase rotation of the incoming unit and the phase rotation of the line are the same.1. Connect the light bulbs between the generator leads and the corresponding line phase, i.e., terminal 1 to line 1 across the open circuit breaker.2. Start the units to be paralleled and bring them up to speed. As they approach the same speed the lights will start to blink. a. If the lights blink in sequence one of the units is connected backward. To correct this remove generator leads 1 and 3 at the circuit breaker and exchange them. This reverses the direction of phase rotation. Line 2 should always be connected to line 2.
Never attempt to work on electrically hot wiring. Stop the electric set before rewiring generator leads. Open circuit breakers before working on the equipment which they control.
b. If lights blink in unison the phase rotation of both engines is the same, and condition 1 has been met.Frequency Adjustment
The speed of units to be paralleled must be the same. Speed refers to the alternating current frequency.1. Allow each electric set to run under load long enough for the internal temperatures to stabilize (about one hour).2. Adjust the governor control to give rated frequency at full load.3. Remove the load and check the high idle speed; it should be approximately 3% above full load speed. If these speeds can not be obtained, contact your Caterpillar dealer.4. For the most consistent results repeat steps 2 and 3. Condition 2 has been met.Voltage Adjustment
The voltage level and voltage droop adjustments determine the amount of circulating currents between generators. Carefully matched voltage regulator adjustments will reduce the circulating currents. Loads of .8 power factor (primarily motors) require a generator voltage droop of about 5%. Voltage droop is expressed as the percentage of voltage change from no load to full load. Use the same voltmeter to make adjustments on each unit to be paralleled.1. Adjust voltage as described for Single Unit Operation, Initial Start-Up.2. With the engine running at high idle, turn the voltage droop clockwise about 1/2 of full range.If driven load is to be unity power factor, set the voltage droop control on all generators at 1/2 of full range and proceed to Step 7. If driven load is to be normal (0.8 power factor) proceed to Step 3.3. Readjust the voltage level control until the voltage is about 5% above desired voltage.4. Apply full load at .8 power factor.If a generator is to be paralleled with other generators, the voltage droop of each generator must be the same to satisfactorily divide reactive load.5. Readjust the voltage droop control to obtain desired voltage with full load at .8 power factor.6. Repeat Steps 3, 4 and 5 for each generator to be paralleled until line voltage is equal to desired level at .8 power factor and no load voltage is approximately 5% above rated voltage.7. Parallel generators and apply the driven load (see the topic Operation/Paralleling). If the sum of the amps of the individual generator amperes exceeds the total amps going to the load by 10% at full load, adjust voltage droop controls to share current proportionally between generators.
Do NOT exceed rated ampere load on any single generator.
8. Tighten the locknuts on all controls and install the access cover. Condition 3 has been met.Starting Multiple Units
Starting-Units are started the same as single units.Paralleling
Units may be paralleled at no load or paralleled with units under load. To parallel two or more units the following conditions must be met:1. Same phase rotation.2. Same voltage level.3. Same voltage droop.4. Same frequency.5. Voltages must be in phase.The first three conditions have been met in the initial start-up for parallel operation.1. Start the unit to be paralleled according to the procedure in the engine operation section.2. Turn the synchronizer lights on.3. After the engine has run long enough to warm up, bring it up to synchronous speed (the same frequency as the unit on the line). The synchronizing lights will begin to blink.4. Using the governor control adjust the speed until the lights blink very slowly.5. The lights are off when the voltages of the two units are in phase. At this point very quickly close the breaker while the lights are out.6. Use governor controls to share KW load between engines.7. After generator temperature has stabilized (1 hr.), adjust the droop control of each generator so as to share the reactive load and to limit the circulating currents. Less droop (moving control CCW) increases the reactive current carried by the generator.The frequency of the incoming unit should be slightly greater than the line frequency. This will allow the incoming unit to assume some of the load rather than add to the system load.Load Division-(Speed Droop)
Once two units have been paralleled their share of the load is determined by the governor control setting. If two units of the same capacity and the same governor characteristics have the same governor control settings they will share the load equally.To transfer the load from one engine to the other follow this procedure:The total load must not exceed the capacity of the engine.1. Increase the governor speed control of one unit to increase the load.2. Reduce the governor speed control of the other unit to decrease the load on that unit.3. Raise or lower the governor speed control of both units to change system frequency.Circulating Currents
When two units are paralleled there will be circulating currents. These currents are not doing useful work, but are flowing between the generators. By determining the total generator amperage and subtracting the amperage going to the load, the amount of circulating current can be determined.Circulating currents are caused by voltage differences between the two units.With cold generator sets, circulating current may be as high as 25% of rated amperes, without being considered harmful. Circulating current is part of the total generator current and this total must not


Parts cover EVINRUDE:

0335474
COVER, Stern bracket, stbd.
0335474 COVER, Stern bracket, stbd.
BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE225CXECS, BE225CXEDE, BE225CXEUD, BE90ELEDR, BE90ELEUA,
0335475
COVER, Stern bracket, port
0335475 COVER, Stern bracket, port
BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE225CXECS, BE225CXEDE, BE225CXEUD, BE90ELEDR, BE90ELEUA,
0342265
 
0342265 COVER, Bracket
BE10EEDD, BE10RELEUS, BE130TLECE, BE130TLEDM, BE130TLEUB, BE15EEDS, BE15RELEUC, BE20SEECB, BE20SEEDA, BE20SEEUM, BE25EECE, BE25EEDM, BE25EEUB, BE30EECS, BE30EEDE, BE30EEUD, BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50DTLEDC, BE50DTLEUR, BE50ESECC, B
0344771
COVER, Thermostat
0344771 COVER, Thermostat
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
0347318
 
0347318 COVER
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5006241
*COVER & SEAL Assy, Shift rod
5006241 *COVER & SEAL Assy, Shift rod
E100FPLSOC, E115DBXAAA, E115DBXABA, E115DBXIIB, E115DBXINE, E115DBXISF, E115DBXSCR, E115DBXSEF, E115DBXSUC, E115DCXAAA, E115DCXABA, E115DCXIIA, E115DCXINM, E115DCXISF, E115DCXSCS, E115DCXSEF, E115DHLAAA, E115DHLABA, E115DHLIIR, E115DHLINA, E115DHLISC
5007367
 
5007367 *COVER, Shift rod
DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, DE150PXINS, DE200CXAAA, DE200CXAAC, DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200PXAAA, DE200PXAAC, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA
5007780
 
5007780 COVER, Electrical bracket
E200DHLSEB, E200DHXSEA, E200HCXSEA, E200HSLSEA, E225DCXSEB, E225DHLSEB, E225DPLSEB, E225DPXSEB, E225HSLSEC, E250DCXSEB, E250DHLSEC, E250DPLSEB, E250DPXSEB, E250HGLSES, E250HSLSES, E300DCXSEC, E300DPXSEC
Back to top