Table 1
J1939 Code and Description CDL Code and Description Comments
3216-11
Aftertreatment #1 Intake NOx : Other Failure Mode 3655-11
Aftertreatment #1 Intake NOx Level Sensor : Other Failure Mode The intake NOx sensor heater cannot generate enough heat or the power supply is intermittent.
3216-12
Aftertreatment #1 Intake NOx : Failure 3655-12
Aftertreatment #1 Intake NOx Level Sensor : Failure A failed intake NOx sensor has been detected.
3226-11
Aftertreatment #1 Outlet NOx : Other Failure Mode 3609-11
Aftertreatment #1 Outlet #1 NOx Level Sensor : Other Failure Mode The outlet NOx sensor heater cannot generate enough heat or the power supply is intermittent.
3226-12
Aftertreatment #1 Outlet NOx : Failure 3609-12
Aftertreatment #1 Outlet #1 NOx Level Sensor : Failure A failed outlet NOx sensor has been detected. Note: Turn the keyswitch to OFF before connecting or disconnecting these components.If the Cat® Electronic Technician (ET) will not communicate with the ECM, refer to Troubleshooting, "Electronic Service Tool Does Not Communicate" before you begin this procedure. The procedure verifies that electrical power is being supplied to the ECM and to the service tool connector.The data links are used to communicate information between the engine ECM and other control modules that are a part of the application. Cat ET also communicates with the ECM via the data links.The service tool connector contains connections for electrical power and for the data links.When the keyswitch is in OFF, Cat ET may communicate with the ECM. However, the communications may be disrupted and the communications may require frequent reconnection. To avoid this problem, place the keyswitch in ON when Cat ET is being used.Cat ET may display the following error message:"The version of the ECM is not recognized and the integrity of the changed parameters and displayed data is not guaranteed."This message indicates that one of the following conditions exist:
The flash file in the ECM is newer than the version of Cat ET.
The latest version of Cat ET has not been installed.
Illustration 1 g03732931
Table 2
Troubleshooting Test Steps Values Results
1. Check the Connectors
A. Remove electrical power from the engine.
B. Thoroughly inspect the connectors. Refer to Troubleshooting, "Electrical Connectors-Inspect" for additional information.
C. Perform a 45 N (10 lb) pull test on the connector wires.
D. Check the harness for abrasions and pinch points.
Connectors and Wiring
Result: The connectors and wiring appear to be OK.
Repair: If a -12 code is active or logged, replace the appropriate NOx sensor. Refer to Special Instruction, REHS8151 for special handling instructions.
Proceed to Test Step 3.
If a -11 code is active or logged, proceed to Test Step 2.
Result: There is a problem with the connectors and/or wiring.
Repair: Repair or replace the connectors or wiring. Ensure that all the seals are properly in place and ensure that the connectors are coupled.
If the problem is not resolved, proceed to Test Step 2.
2. Check the Voltage to the Affected Sensor
A. Disconnect the affected sensor from the wiring harness.
B. Apply electrical power to the engine.
C. Measure the voltage on the wiring harness connector between the following:
- +Battery (supply) and -Battery (return)
Battery Voltage
Result: The measured voltage is equal to battery voltage.
Repair: Replace the failed NOx sensor. Refer to Special Instruction, REHS8151 for special handling instructions.
Proceed to Test Step 3.
Result: The measured voltage is not equal to battery voltage.
Repair: There is a problem with an intermittent battery supply. Check the power supply to the affected sensor.
If the problem is not resolved, proceed to Test Step 3.
3. Operate the Engine
A. Apply electrical power to the engine.
B. Start the engine.
C. Run the engine until normal operating temperature is reached.
D. Connect Cat ET to the service tool connector.
E. Use Cat ET to monitor the following:
- Codes
Codes
Result: A code is not active.
Return to service.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts cover EVINRUDE:
0310781
0310781 COVER,Choke switch
100193A, 100293R, 100882B, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 175740S, 200640S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 33002M, 33802M, 33902A, 35602G,
0388618
0388618 COVER & SEAL ASSY
100990S, 115890C, 150940C, C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100MLCSC, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLEIB, E100WTLENE, E100WTLESM, E100WTLZ,
0391858
0391858 COVER & SWITCH ASSY.
C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100STLCCA, E100STLCEM, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLESM, E100WTLZ, E110MLCCA, E110MLCDC, E110MLCEM, E110MLCUR, E115MLCNB, E115MLCOS, E115MLCRD, E115MLCTE
0329873
0329873 COVER, Handle
C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100STLCCA, E100STLCEM, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLESM, E100WTLZ, E110MLCCA, E110MLCDC, E110MLCEM, E110MLCUR, E115MLCOS, E115MLCRD, E115MLESB, E120TLCCA
0583090
0583090 COVER ASSY.
C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100STLCCA, E100WMLCDR, E100WMLCOC, E100WTLCUA, E110MLCCA, E110MLCDC, E110MLCUR, E115MLCOS, E120TLCCA, E120TLCDC, E120TLCOS, E120TLCUR, E140CXCCS, E140TLCDC, E140TLCOS, E140TLCUA, E150CXCCA, E
0328640
0328640 COVER PLATE
CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E120TLCCA, E120TLCDC, E120TLCEM, E120TLCOS, E120TLCUR, E120TLESB, E125ESXESS, E125ESXW, E140CXCCS, E140CXCEC, E140CXESR, E140TLCDC, E140TLCOS, E140TLCUA, E185ESXESS, E185ESXW, E200CXCCR, E200CXCEA, E200
0329745
0329745 COVER, Thermostat stbd.
CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E120TLCCA, E120TLCDC, E120TLCEM, E120TLCOS, E120TLCUR, E120TLEIE, E120TLESB, E125ESXESS, E125ESXW, E140CXCCS, E140CXCEC, E140CXEIA, E140CXESR, E140TLCDC, E140TLCOS, E140TLCUA, E185ESXENR, E185ESXESS, E1
0329744
0329744 COVER, Thermostat, port
CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E120TLCCA, E120TLCDC, E120TLCEM, E120TLCOS, E120TLCUR, E120TLEIE, E120TLESB, E125ESXESS, E125ESXW, E140CXCCS, E140CXCEC, E140CXEIA, E140CXESR, E140TLCDC, E140TLCOS, E140TLCUA, E185ESXENR, E185ESXESS, E1