0432784 COVER, Stbd. EVINRUDE
E250CXEIE, E250CXEND, E300CXCEM, E300CXEIE, E300CXEND, E300CXESB
COVER
Price: query
Rating:
BRP EVINRUDE entire parts catalog list:
- LOWER ENGINE COVER » 0432784
E300CXCEM, E300PLCEM, E300PXCEM 1989
E300CXEIE, E300PLEIE, E300PXEIE 1991
E300CXEND, E300PLEND, E300PXEND 1992
E300CXESB, E300PLESB, E300PXESB 1990
Information:
Table 1
Required Tools
Tool Part Number Part Description Qty
A 456-4371 Lever Puller Hoist Gp 1
589-7434 Link Bracket As 1
B 386-6031 Lever Puller Hoist Gp 1
421-5663 Lifting Eye Assembly 1
C 1U-6693 Forcing Screw 2
ELECTROCUTION HAZARD - The electrical system contains hazardous voltage levels.DO NOT remove any covers that will expose energized hazardous-voltage electrical components without shutting down and discharging the electrical system .DO NOT perform any maintenance on the electrical system until after the electrical system has been shutdown and the voltage has been discharged by qualified personnel.Read and understand the instructions and warnings found in the Operation and Maintenance Manual to properly shutdown the electrical system and discharge hazardous-voltage electrical components.Failure to follow these instructions could result in personal injury or death.
ELECTROCUTION HAZARD - Ensure proper grounding.Avoid a buildup of hazardous live voltages on exposed surfaces by ensuring that all grounding wires/straps are always properly connected.Disconnected grounding wires, including grounding wires/straps for hazardous-voltage components and electrical enclosures, must be properly reconnected before connecting equipment to the power supply.Failure to follow these instructions could result in personal injury or death.
When service or maintenance must be performed in a hazardous-voltage component enclosure, always assume that a hazardous level of voltage could be present.Qualified personnel should manually check for hazardous-voltage using electrical measuring tools that have the capacity to measure the hazardous-voltage components being checked.The level of voltage present must be confirmed to be below 50 VDC before any exposure to the hazardous-voltage components can take place.Failure to follow these instructions could result in personal injury or death.
There may be government regulations and/or local regulations, and/or site-specific rules and regulations, that govern the operation, service, or maintenance of high-voltage machines. Comply with applicable rules and regulations for the work place.Consult your Cat dealer for additional information.
Personal injury or death can occur from heavy components falling during removal or installation.Properly support the component with a suitable lifting device during removal or installation.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, PERJ1017, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products.Dispose of all fluids according to local regulations and mandates.
Personal injury can result from hot oil or hot components.At operating temperature, oil is hot and under pressure. Hot oil can cause burns.Remove the fill cap only when the engine is stopped, and the fill cap is cool enough to touch with your bare hand.Do not allow hot oil or components to contact skin.
Prepare the machine for maintenance. Refer to Operation and Maintenance Manual, "Prepare the Machine for Maintenance".
Release the system pressure. Refer to Operation and Maintenance Manual, "System Pressure Release".
Turn the power disconnect switch to the OFF position.
Illustration 1 g06465486
Use two people to remove fan shroud (1). The weight of fan shroud (1) is approximately 27 kg (60 lb).
Illustration 2 g06465488
Illustration 3 g06465490
Install Tooling (A). Attach Tooling (A) to fan assembly (2). The weight of fan assembly (2) is approximately 159 kg (350 lb).
Parts cover EVINRUDE:
0310781
0310781 COVER,Choke switch
100193A, 100293R, 100882B, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 175740S, 200640S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 33002M, 33802M, 33902A, 35602G,
0320864
0320864 COVER,Mount bracket lower
100990S, 115790S, 115890C, 150840S, 150940C, 175740S, 200640S, C155WTLM, E100MLCSC, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLESB, E100WTLCUA, E100WTLEIB, E100WTLENE, E100WTLESM, E100WTLZ, E110MLCCA, E110MLCEM, E110MLCUR, E115JLEIE, E115
0391858
0391858 COVER & SWITCH ASSY.
C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100STLCCA, E100STLCEM, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLESM, E100WTLZ, E110MLCCA, E110MLCDC, E110MLCEM, E110MLCUR, E115MLCNB, E115MLCOS, E115MLCRD, E115MLCTE
0329873
0329873 COVER, Handle
C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100STLCCA, E100STLCEM, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLESM, E100WTLZ, E110MLCCA, E110MLCDC, E110MLCEM, E110MLCUR, E115MLCOS, E115MLCRD, E115MLESB, E120TLCCA
0328640
0328640 COVER PLATE
CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E120TLCCA, E120TLCDC, E120TLCEM, E120TLCOS, E120TLCUR, E120TLESB, E125ESXESS, E125ESXW, E140CXCCS, E140CXCEC, E140CXESR, E140TLCDC, E140TLCOS, E140TLCUA, E185ESXESS, E185ESXW, E200CXCCR, E200CXCEA, E200
0329745
0329745 COVER, Thermostat stbd.
CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E120TLCCA, E120TLCDC, E120TLCEM, E120TLCOS, E120TLCUR, E120TLEIE, E120TLESB, E125ESXESS, E125ESXW, E140CXCCS, E140CXCEC, E140CXEIA, E140CXESR, E140TLCDC, E140TLCOS, E140TLCUA, E185ESXENR, E185ESXESS, E1
0329562
0329562 COVER, Temp switch
BE10FAEDC, BE10FAEUR, BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE115ELEDR, BE115ELEUA, BE115GLECM, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE
0329744
0329744 COVER, Thermostat, port
CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E120TLCCA, E120TLCDC, E120TLCEM, E120TLCOS, E120TLCUR, E120TLEIE, E120TLESB, E125ESXESS, E125ESXW, E140CXCCS, E140CXCEC, E140CXEIA, E140CXESR, E140TLCDC, E140TLCOS, E140TLCUA, E185ESXENR, E185ESXESS, E1