Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
101-13
Crankcase Air Pressure Sensor : Out of Calibration 101-13
Crankcase Air Pressure Sensor : Out of Calibration During key on, the signal voltage from the crankcase air pressure sensor indicated a crankcase air pressure greater than +/- 1.5 kPa (0.2 psi).
There is not a reference sensor for this sensor.
2452-13
Generator Total Real Power : Out of Calibration N/A The code will be active when using a secondary generator power sensor and the values between the PWM and analog signal differ by more than 100 kW.
3563-13
Engine Intake Manifold #1 Absolute Pressure : Out of Calibration 1785-13
Intake Manifold Pressure Sensor : Out of Calibration During key on, the signal voltage from the intake manifold pressure sensor indicated an intake manifold pressure greater than +/- 18 kPa (3 psi).
Reference sensor: Atmospheric Pressure Sensor
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
Note: The engine coolant temperature must be greater than 0° C (32° F) before beginning this procedure.
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A code is active or logged.
Proceed to Test Step 2.
2. Check for Debris
A. Turn the keyswitch to the OFF position.
B. Check the sensor for debris.
C. If applicable, check the reference sensor for debris.
D. Check the sensor measurement port for blockage by debris.
E. If debris is found, clear the debris from the measurement port and replace the sensor.
F. Connect Cat ET.
G. Use Cat ET to monitor the following code:
- Codes
Debris
Result: The sensor measurement port is not blocked by debris.
Proceed to Test Step 3.
Result: A -13 code is not active.
Return to service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 3.
3. Inspect the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Inspect the sensor connector for moisture and corrosion.
Moisture
Result: The sensor connector does not have moisture or corrosion.
Proceed to Test Step 5.
Result: The sensor connector has moisture and/or corrosion.
Proceed to Test Step 4.
4. Remove any moisture and/or corrosion
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor connector.
C. Remove any moisture and/or corrosion from the outside of the connector. Check for moisture and corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following code:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 5.
5. Check for Moisture and/or Corrosion in the Circuit
A. Turn the keyswitch to the OFF position.
B. Check all the connectors in the circuit for moisture and/or corrosion.
C. Check for corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts cylinder EVINRUDE:
0394601
0394601 CYLINDER ASSY., Tilt
BE250CXECB, BE250CXEDA, BE250CXEUM, CE275TLCOS, CE300TLCOS, E250CXARC, E250CXEIE, E250CXEND, E250CXEOR, E275CLCUR, E275CXCCA, E300CLCUR, E300CXCCA, E300CXCEM, E300CXEIE, E300CXEND, E300CXEOR, E300CXERC, E300CXESB
0913331
0913331 CYLINDER, Starboard
BE250CXEDA, BE250CXEUM, E185ESXESS, E185ESXW, E200CXCCR, E200CXCEA, E200CXESM, E225CXCCE, E225CXCED, E225CXESS, E250CXARC, E250CXATF, E250CXEIE, E250CXEND, E250CXEOR, E275CXCCA, E300CXCCA, E300CXCEM, E300CXEIE, E300CXEND, E300CXEOR, E300CXERC, E300CX
0985526
0985526 CYLINDER & VALVE ASSY.
E185ESXESS, E185ESXW, E200CXCCR, E200CXCEA, E200CXESM, E225CXCCE, E225CXCED, E225CXESS, E275CXCCA, E300CXCCA, E300CXCEM, E300CXESB
0398758
0398758 CYLINDER & C'CASE ASSY.
E250CXATF, E250CXEIE, E250CXEND, E275CXCCA, E300CXCCA, E300CXCEM, E300CXEIE, E300CXEND, E300CXESB, E300CXETF
0431635
0434502
0987052
0987052 CYLINDER & VALVE ASSY.
BE250CXEDA, BE250CXEUM, E250CXARC, E250CXATF, E250CXEIE, E250CXEND, E250CXEOR, E300CXEIE, E300CXEND, E300CXEOR, E300CXERC, E300CXETF
0435719