5007978 CYLINDER / CRANKCASE Assy, 3.4 L EVINRUDE
DE250CXISF, DE250PXISF, DE300CXISF, DE300PXISF, E200DHLSEB, E200DHXSEA, E200HCXSEA, E200HSLSEA, E225DCXISE, E225DCXSEB, E225DHLISE, E225DHLSEB, E225DPLISE, E225DPLSEB, E225DPXISE, E225DPXSEB, E225HSLISF, E225HSLSEC, E250DCXISE, E250DCXSEB, E250DHLSEC
CYLINDER
Price: query
Rating:
Compatible models:
DE250CXISF
DE250PXISF
DE300CXISF
DE300PXISF
E200DHLSEB
E200DHXSEA
E200HCXSEA
E200HSLSEA
E225DCXISE
E225DCXSEB
E225DHLISE
E225DHLSEB
E225DPLISE
E225DPLSEB
E225DPXISE
E225DPXSEB
E225HSLISF
E225HSLSEC
E250DCXISE
E250DCXSEB
E250DHLSEC
E250DPLISE
E250DPLSEB
E250DPXISE
E250DPXSEB
E250HGLSES
E250HSLSES
E300DCXISF
E300DCXSEC
E300DPXISF
E300DPXSEC
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- CYLINDER & CRANKCASE » 5007978
DE300CXISF, DE300CXISG, DE300CXISS, DE300CZISF, DE300CZISG, DE300CZISS 2010
DE300PXISF, DE300PXISG, DE300PXISS, DE300PZISF, DE300PZISG, DE300PZISS 2010
E200DHLSEB 2009
E200DHXSEA, E200HVLSEC 2009
E200HCXSEA 2009
E200HSLSEA 2009
E225DCXISE, E225DCXISF, E225DCZISE, E225DCZISF 2010
E225DCXSEB, E225DCZSEB 2009
E225DHLISE, E225DHLISF, E225DHXISB, E225DHXISF 2010
E225DHLSEB, E225DHXSEM 2009
E225DPLISE, E225DPLISF 2010
E225DPLSEB 2009
E225DPXISE, E225DPXISF, E225DPZISE, E225DPZISF 2010
E225DPXSEB, E225DPZSEB 2009
E225HSLISF, E225HSLISR 2010
E225HSLSEC 2009
E250DCXISE, E250DCXISF, E250DCZISE, E250DCZISF 2010
E250DCXSEB, E250DCZSEB 2009
E250DHLSEC, E250DHXSEC 2009
E250DPLISE, E250DPLISF 2010
E250DPLSEB 2009
E250DPXISE, E250DPXISF, E250DPZISE, E250DPZISF 2010
E250DPXSEB, E250DPZSEB 2009
E250HGLSES, E250HGXSES 2009
E250HSLSES 2009
E300DCXISF, E300DCXISG, E300DCXISR, E300DCZISF, E300DCZISG, E300DCZISR 2010
E300DCXSEC, E300DCZSEC 2009
E300DPXISF, E300DPXISG, E300DPXISR, E300DPZISF, E300DPZISG, E300DPZISR, E300DSLISC, E300DSLISF, E300DSLISG 2010
E300DPXSEC, E300DPZSEC, E300DSLSES 2009
Information:
Checking Air Cleaner Service Indicator
Before starting, check the window of the indicator. If the red piston is locked in the raised position, service the air cleaner as outlined. Have spare elements on hand to install while cleaning used elements.
Service the air cleaner with the engine STOPPED.
PISTON LOCKED IN RAISED POSITIONSingle Stage Air Cleaner
Servicing Single Stage Air Cleaner
1. Remove the air cleaner cover and element.
REMOVING COVER AND FILTER ELEMENT2. Cover the air inlet opening to prevent dirt from entering the engine.3. Clean the inside of the air cleaner cover and the air cleaner body.
CLEANING INSIDE OF AIR CLEANER 1. Air Inlet Cover4. Inspect the replacement element for damage and dirt.5. Remove the covering from the air inlet opening.6. Install the element.
INSTALLING AIR CLEANER ELEMENT7. Install the air cleaner cover.8. Reset the service indicator piston by pushing the reset button. (See the instructions for air cleaner element cleaning).
RESETTING AIR INDICATOR PISTONTwo Stage Air Cleaner
Emptying Dust Collector Cup
1. Loosen the clamping bolt on the lower body.2. Remove and empty the dust collector cup.3. Inspect and install the seal; install a new seal if necessary.
REMOVING DUST CUP 1. Seal4. Inspect the tubes in the lower body. If dirty, clean the tubes with a round bottle brush.5. Install the dust collector cup.Cleaning The Lower Body
1. Remove the dust collector cup.2. Loosen the clamping bolt on the upper body.
REMOVING LOWER BODY 1. Seal3. Remove the lower body. Clean the tubes from both ends.4. Inspect and install the upper body seal. Install a new seal if it is damaged.Installing Replacement Filter Element
1. Remove the cover.
REMOVING COVER AND INNER COVER2. Remove the inner cover and filter element. In cold weather, a stuck inner cover may be removed by warming the air cleaner cover to 70-75°F (21-24°C).
REMOVE ELEMENT3. Clean all parts of the air cleaner.4. Inspect the replacement element for damage and cleanliness.5. Install the element, inner cover, and wing nut. Tighten the wing nut to prevent dust from bypassing the filter element.6. Install the cover.If, after servicing the air cleaner, the exhaust smoke and/or loss of power continues; or the service indicator locks in the raised position, discard that element and install a new element. Install a new element at least once a year.Cleaning Used Air Cleaner Elements
Cleaning With Pressure Air
1. Use clean, dry air-100 PSI maximum. Hold the nozzle at least one inch from the element and at a slight angle. (A direct blast can rip the pleating.)
CLEANING ELEMENT WITH AIR2. Direct the air stream along the complete length of each pleat on the CLEANEST side of the element. (This will loosen the dirt from the dirtier side.)3. Blow the loosened dirt from the DIRTY side.4. Direct the air from the CLEAN side through to the DIRTY side to remove dirt blown into the pleating.Cleaning With Water
1. Use clean water at no more than 40 PSI. Do not use a nozzle.2. Direct the water stream along the complete length of each pleat on the CLEAN side of the element.
CLEANING ELEMENT WITH WATER3. Direct water along the complete length of each pleat on the DIRTY side of the element.4. Rinse the CLEAN side of the element.5. Allow the cleaned element to dry thoroughly.Cleaning With Detergent
1. Wash both sides of the element in a solution of warm water and non-sudsing household detergent.2. Rinse the CLEANEST side of the element with clean water (40 PSI maximum) along the complete length of each pleat.
WASHING ELEMENT WITH DETERGENT3. Rinse the opposite side of the element along the complete length of each pleat.4. Rinse the first side again to remove all loosened dirt.5. Allow the cleaned element to dry thoroughly.Storing Cleaned Elements
1. Hold the dried element in front of a lighted electric bulb. Carefully inspect the element for tiny, pinpoints of light. Any light showing indicates a pleat has ruptured and will tear with further use. Discard the element.
INSPECTING ELEMENT2. Wrap usable elements in heavy paper.3. Store the wrapped element in a dry, clean place.Precleaner
Servicing
When the precleaner body is 3/4 full, remove and empty the precleaner. Wash the precleaner in water.
AIR CLEANER PRECLEANER
Before starting, check the window of the indicator. If the red piston is locked in the raised position, service the air cleaner as outlined. Have spare elements on hand to install while cleaning used elements.
Service the air cleaner with the engine STOPPED.
PISTON LOCKED IN RAISED POSITIONSingle Stage Air Cleaner
Servicing Single Stage Air Cleaner
1. Remove the air cleaner cover and element.
REMOVING COVER AND FILTER ELEMENT2. Cover the air inlet opening to prevent dirt from entering the engine.3. Clean the inside of the air cleaner cover and the air cleaner body.
CLEANING INSIDE OF AIR CLEANER 1. Air Inlet Cover4. Inspect the replacement element for damage and dirt.5. Remove the covering from the air inlet opening.6. Install the element.
INSTALLING AIR CLEANER ELEMENT7. Install the air cleaner cover.8. Reset the service indicator piston by pushing the reset button. (See the instructions for air cleaner element cleaning).
RESETTING AIR INDICATOR PISTONTwo Stage Air Cleaner
Emptying Dust Collector Cup
1. Loosen the clamping bolt on the lower body.2. Remove and empty the dust collector cup.3. Inspect and install the seal; install a new seal if necessary.
REMOVING DUST CUP 1. Seal4. Inspect the tubes in the lower body. If dirty, clean the tubes with a round bottle brush.5. Install the dust collector cup.Cleaning The Lower Body
1. Remove the dust collector cup.2. Loosen the clamping bolt on the upper body.
REMOVING LOWER BODY 1. Seal3. Remove the lower body. Clean the tubes from both ends.4. Inspect and install the upper body seal. Install a new seal if it is damaged.Installing Replacement Filter Element
1. Remove the cover.
REMOVING COVER AND INNER COVER2. Remove the inner cover and filter element. In cold weather, a stuck inner cover may be removed by warming the air cleaner cover to 70-75°F (21-24°C).
REMOVE ELEMENT3. Clean all parts of the air cleaner.4. Inspect the replacement element for damage and cleanliness.5. Install the element, inner cover, and wing nut. Tighten the wing nut to prevent dust from bypassing the filter element.6. Install the cover.If, after servicing the air cleaner, the exhaust smoke and/or loss of power continues; or the service indicator locks in the raised position, discard that element and install a new element. Install a new element at least once a year.Cleaning Used Air Cleaner Elements
Cleaning With Pressure Air
1. Use clean, dry air-100 PSI maximum. Hold the nozzle at least one inch from the element and at a slight angle. (A direct blast can rip the pleating.)
CLEANING ELEMENT WITH AIR2. Direct the air stream along the complete length of each pleat on the CLEANEST side of the element. (This will loosen the dirt from the dirtier side.)3. Blow the loosened dirt from the DIRTY side.4. Direct the air from the CLEAN side through to the DIRTY side to remove dirt blown into the pleating.Cleaning With Water
1. Use clean water at no more than 40 PSI. Do not use a nozzle.2. Direct the water stream along the complete length of each pleat on the CLEAN side of the element.
CLEANING ELEMENT WITH WATER3. Direct water along the complete length of each pleat on the DIRTY side of the element.4. Rinse the CLEAN side of the element.5. Allow the cleaned element to dry thoroughly.Cleaning With Detergent
1. Wash both sides of the element in a solution of warm water and non-sudsing household detergent.2. Rinse the CLEANEST side of the element with clean water (40 PSI maximum) along the complete length of each pleat.
WASHING ELEMENT WITH DETERGENT3. Rinse the opposite side of the element along the complete length of each pleat.4. Rinse the first side again to remove all loosened dirt.5. Allow the cleaned element to dry thoroughly.Storing Cleaned Elements
1. Hold the dried element in front of a lighted electric bulb. Carefully inspect the element for tiny, pinpoints of light. Any light showing indicates a pleat has ruptured and will tear with further use. Discard the element.
INSPECTING ELEMENT2. Wrap usable elements in heavy paper.3. Store the wrapped element in a dry, clean place.Precleaner
Servicing
When the precleaner body is 3/4 full, remove and empty the precleaner. Wash the precleaner in water.
AIR CLEANER PRECLEANER
Parts cylinder EVINRUDE:
5005909
5005909 CYLINDER / CRANKCASE Assy
DE150CXAAA, DE150CXAAC, DE150PXAAA, DE150PXAAC, DE200CXAAA, DE200CXAAC, DE200PXAAA, DE200PXAAC, E135DHLAAB, E135DHXAAC, E135HCXAAC, E135HSLAAB, E150DBXAAA, E150DBXAAC, E150DCXAAA, E150DCXAAC, E150DHLAAA, E150DPLAAA, E150DPXAAA, E150DPXAAC, E150DSLAAA
5005916
5005916 CYLINDER / CRANKCASE Assy
DE150CXAAA, DE150CXAAC, DE150PXAAA, DE150PXAAC, DE200CXAAA, DE200CXAAC, DE200PXAAA, DE200PXAAC, E135DHLAAB, E135DHXAAC, E135HCXAAC, E135HSLAAB, E150DBXAAA, E150DBXAAC, E150DCXAAA, E150DCXAAC, E150DHLAAA, E150DPLAAA, E150DPXAAA, E150DPXAAC, E150DSLAAA
5006342
5006342 Cylinder/Crankcase Gasket & Seal Kit
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5007634
5007634 CYLINDER / CRANKCASE Assy, 225 / 250 HP
E200DHLSCF, E200DHLSCG, E200DHLSCM, E200DHLSEB, E200DHXSCF, E200DHXSCG, E200DHXSCR, E200DHXSEA, E200HCXSCF, E200HCXSCG, E200HCXSCR, E200HCXSEA, E200HSLSCF, E200HSLSCG, E200HSLSCR, E200HSLSEA, E200HVLSCF, E200HVLSCG, E200HVLSCS, E225DCXSCF, E225DCXSCG
5007635
5007635 CYLINDER / CRANKCASE Assy, 200 HP
E200DHLSCF, E200DHLSCG, E200DHLSCM, E200DHLSEB, E200DHXSCF, E200DHXSCG, E200DHXSCR, E200DHXSEA, E200HCXSCF, E200HCXSCG, E200HCXSCR, E200HCXSEA, E200HSLSCF, E200HSLSCG, E200HSLSCR, E200HSLSEA, E200HVLSCF, E200HVLSCG, E200HVLSCS, E225DCXSCF, E225DCXSCG
5007297
5007297 CYLINDER / CRANKCASE Assy
E200DHLSEB, E200DHXSEA, E200HCXSEA, E200HSLSEA, E225DCXSEB, E225DHLSEB, E225DPLSEB, E225DPXSEB, E225HSLSEC, E250DCXSEB, E250DHLSCS, E250DHLSEC, E250DPLSEB, E250DPXSEB, E250HGLSES, E250HSLSES, E300DCXSCS, E300DCXSEC, E300DPXSCS, E300DPXSEC
5007698
5007698 Cylinder/Crankcase Gasket & Seal Kit
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD, DE250PXISF, DE300CXAAA
5007977
5007977 CYLINDER / CRANKCASE Assy, 3.3 L