5008167 CYLINDER/CRANKCASE Assy, 25-30 HP EVINRUDE
E15DHPLAAA, E15DHPLAAB, E15DHPLIIC, E15DHPLINR, E15DHPLISS, E15DHTLAAA, E15DHTLAAB, E15DHTLIIC, E15DHTLINR, E15DHTLISS, E25DELAAA, E25DELIIH, E25DELINA, E25DELISC, E25DPLAAA, E25DPLAAB, E25DPLIIG, E25DPLIIH, E25DPLINA, E25DPLISC, E25DRAAA, E25DRIIH,
CYLINDER
Price: query
Rating:
Compatible models:
E15DHPLAAA
E15DHPLAAB
E15DHPLIIC
E15DHPLINR
E15DHPLISS
E15DHTLAAA
E15DHTLAAB
E15DHTLIIC
E15DHTLINR
E15DHTLISS
E25DELAAA
E25DELIIH
E25DELINA
E25DELISC
E25DPLAAA
E25DPLAAB
E25DPLIIG
E25DPLIIH
E25DPLINA
E25DPLISC
E25DRAAA
E25DRIIH
E25DRINA
E25DRISC
E25DTEAAA
E25DTEIIG
E25DTEIIH
E25DTEINA
E25DTEISC
E25DTLAAA
E25DTLAAB
E25DTLIIH
E25DTLINA
E25DTLISC
E30DELAAA
E30DELIIH
E30DELINA
E30DELISC
E30DPLAAA
E30DPLAAB
E30DPLIIH
E30DPLINA
E30DPLISC
E30DRAAA
E30DRIIG
E30DRIIH
E30DRINA
E30DRISC
E30DTELAAA
E30DTELIIH
E30DTELINA
E30DTELISC
E30DTLAAA
E30DTLAAB
E30DTLIIH
E30DTLINA
E30DTLISC
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- CYLINDER & CRANKCASE » 5008167
E15DHPLIIC, E15DHPLIIH, E15HPSLIIH, E15HPSLIIS 2011
E15DHPLINR, E15HPSLINC, E15HPSXINC 2012
E15DHPLISS 2010
E15DHTLAAA, E15HTSLAAA, E15HTSXAAA 2012
E15DHTLAAB, E15HTSLAAB, E15HTSXAAB 2012
E15DHTLIIC, E15DHTLIIH, E15HTSLIIH, E15HTSLIIS 2011
E15DHTLINR, E15HTSLINC, E15HTSXINC 2012
E15DHTLISS 2010
E25DELAAA, E25DELAAB 2012
E25DELIIH, E25DELIIR 2011
E25DELINA 2012
E25DELISC 2010
E25DPLAAA, E25DPSLAAA 2012
E25DPLAAB, E25DPSLAAB 2012
E25DPLIIG 2011
E25DPLIIH, E25DPLIIR, E25DPSLIIH, E25DPSLIIS 2011
E25DPLINA, E25DPSLINC 2012
E25DPLISC 2010
E25DRAAA, E25DRAAB, E25DRLAAA, E25DRLAAB, E25DRSAAA, E25DRSAAB, E25DRSLAAA, E25DRSLAAB 2012
E25DRIIH, E25DRIIR, E25DRLIIH, E25DRLIIR, E25DRSIIH, E25DRSIIS, E25DRSLIIH, E25DRSLIIS 2011
E25DRINA, E25DRLINA, E25DRSINC, E25DRSLINC 2012
E25DRISC, E25DRLISC 2010
E25DTEAAA, E25DTEAAB, E25DTELAAA, E25DTELAAB, E25TESLAAA, E25TESLAAB 2012
E25DTEIIG 2011
E25DTEIIH, E25DTEIIR, E25DTELIIH, E25DTELIIR, E25TESLIIH, E25TESLIIS 2011
E25DTEINA, E25DTELINA, E25TESLINC 2012
E25DTEISC, E25DTELISC 2010
E25DTLAAA, E25DTSLAAA 2012
E25DTLAAB, E25DTSLAAB 2012
E25DTLIIH, E25DTLIIR, E25DTSLIIH, E25DTSLIIS 2011
E25DTLINA, E25DTSLINC 2012
E25DTLISC 2010
E30DELAAA, E30DELAAB 2012
E30DELIIH, E30DELIIR 2011
E30DELINA 2012
E30DELISC 2010
E30DPLAAA, E30DPSLAAA 2012
E30DPLAAB, E30DPSLAAB 2012
E30DPLIIH, E30DPLIIR, E30DPSLIIH, E30DPSLIIS 2011
E30DPLINA, E30DPSLINC 2012
E30DPLISC 2010
E30DRAAA, E30DRAAB, E30DRLAAA, E30DRLAAB, E30DRSAAA, E30DRSAAB, E30DRSLAAA, E30DRSLAAB 2012
E30DRIIG, E30DRLIIG 2011
E30DRIIH, E30DRIIR, E30DRLIIH, E30DRLIIR, E30DRSIIH, E30DRSIIS, E30DRSLIIH, E30DRSLIIS 2011
E30DRINA, E30DRLINA, E30DRSINC, E30DRSLINC 2012
E30DRISC, E30DRLISC 2010
E30DTELAAA, E30DTELAAB, E30TESLAAA, E30TESLAAB 2012
E30DTELIIH, E30DTELIIR, E30TESLIIH, E30TESLIIS 2011
E30DTELINA, E30TESLINC 2012
E30DTELISC 2010
E30DTLAAA, E30DTSLAAA 2012
E30DTLAAB, E30DTSLAAB 2012
E30DTLIIH, E30DTLIIR, E30DTSLIIH, E30DTSLIIS 2011
E30DTLINA, E30DTSLINC 2012
E30DTLISC 2010
Information:
The water cooled air compressor receives coolant through a tube that is connected to the water manifold in the side of the cylinder block. Coolant returns through a tube from the air compressor head to the diesel engine cylinder head.Until the coolant reaches the temperature required to open the temperature regulators, coolant bypasses the radiator and flows directly back to the water pump.When the coolant reaches the temperature required to open the temperature regulators, coolant is then directed through the radiator.A pressure relief cap assembly is used to control the pressure in the cooling system, and prevents loss of coolant through the radiator overflow tube.Pressurizing the cooling system serves two purposes. First, it permits safe operation at coolant temperatures higher than the normal boiling point, providing a margin of cooling for intermittent peak loads. Secondly it prevents cavitation in the water pump, and reduces the possibility of air or steam pockets forming in the coolant passages. Proper operation of the pressure relief cap assembly is essential. A pressure relief cap allows pressure (and some coolant, if the cooling system is too full) to escape when the pressure in the cooling system exceeds the capacity of the pressure cap. Loss of pressure will cause steam to form when coolant temperature is above the normal boiling point. Water Pump: The centrifugal-type water pump has three seals, one prevents leakage of water and the other two prevent leakage of lubricant.An opening in the bottom of the pump housing, allows any leakage at the water seal or the rear bearing oil seal to escape. Fan: The fan is driven by three V-belts, from a pulley on the crankshaft. Belt tension is adjusted by moving the bracket assembly which includes the fan mounting and pulley. Water Temperature Regulator: The water temperature regulator restricts the flow of coolant through the radiator, until the coolant reaches operating temperature; approximately 165°F (74°C.) The regulator is fully open at approximately 180°F (82°C.)The shunt cooling system is used in many truck installations. The shunt cooling system provides continuous circulation which helps prevent aeration and pump cavitation by maintaining a positive head of coolant at the pump inlet at all times. It differs from the conventional cooling system in that the radiator top tank is divided into two compartments (upper and lower) with a small air/coolant bleed tube connecting them. A shunt line located as low as possible in the upper chamber directs coolant to the pump inlet. When the coolant reaches the temperature required to open the temperature regulators, coolant is directed into the bottom chamber of the radiator top tank, down through the radiator core to the suction line of the pump and then to the engine. Coolant, which may contain some air will flow from the bottom chamber to the top chamber through the small air/coolant bleed tube. The air will separate from the coolant in the upper chamber. The coolant will flow out the shunt line and the air remain in the upper chamber until excessive pressure is built up, at which time it will vent out through the pressurized relief cap. Air which may accumulate in the engine is expelled from the highest point in the engine cooling system to the radiator upper chamber through an external vent line.Thermal controlled shutter stats or radiator shutters are an effective way to control the air flow through the radiator for maintaining proper operating temperatures. The shutters are thermostatically controlled to open 5 to 10 degrees above the temperature regulator when in full open position.
Parts cylinder EVINRUDE:
0355133
0355133 CYLINDER HEAD
E15DHPLAAA, E15DHPLAAB, E15DHPLIIC, E15DHPLINR, E15DHPLISS, E15DHTLAAA, E15DHTLAAB, E15DHTLIIC, E15DHTLINR, E15DHTLISS, E25DELAAA, E25DELIIH, E25DELINA, E25DELISC, E25DELSES, E25DPLAAA, E25DPLAAB, E25DPLIIG, E25DPLIIH, E25DPLINA, E25DPLISC, E25DPLSES
5008984
5008984 CYLINDER SEAL KIT
E15DHPLAAA, E15DHPLAAB, E15DHTLAAA, E15DHTLAAB, E25DPLAAA, E25DPLAAB, E25DTLAAA, E25DTLAAB, E30DPLAAA, E30DPLAAB, E30DTLAAA, E30DTLAAB, E40DPLAAA, E40DPLABA, E40DTLAAA, E40DTLABA, E50DPLAAA, E50DPLABA, E50DTLAAA, E50DTLABA, E60DPLAAA, E60DPLABA, E60D