0285091 EVINRUDE DECAL SET, Evinrude


0285091 DECAL SET, Evinrude EVINRUDE E40WREES, E40WRLSSC, E55WREES, E55WRLSSC, SE40RPLT2, SE55RSLM2 DECAL
0285091 DECAL SET, Evinrude EVINRUDE
Rating:
78

Buy DECAL SET, Evinrude 0285091 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 22
 

BRP EVINRUDE entire parts catalog list:

E40WREES, E40WRLEES, E40WRYEES 1999
E40WRLSSC, E40WRSSC, E40WRYSSC 2000
E55WREES, E55WRLEES, E55WRYEES 1999
E55WRLSSC, E55WRSSC, E55WRYSSC 2000
SE40RPLT2, SE40RPT2, SE40RPYT2 1998
SE55RSLM2, SE55RSM2, SE55RSYM2 1998

Information:

Start By:
Connect the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect" for the machine that is being serviced.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Accidental machine starting can cause injury or death to personnel working on the machine.To avoid accidental machine starting, turn the battery disconnect switch to the OFF position and remove the key. If the machine is not equipped with a battery disconnect switch, disconnect the battery cables from the battery and tape the battery clamps.Place a do not operate tag at the battery disconnect switch location to inform personnel that the machine is being worked on.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Cap all lines, all hoses, and all tubes and plug all lines, all hoses, and all tubes. This will help to prevent fluid loss and this will help to keep contaminants from entering the system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g00847221
Loosen bolt (3) and two nuts (2) .
Remove the belt from refrigerant compressor (1) .
Illustration 2 g00847243
Disconnect two hose assemblies (4) .
Disconnect wiring harness (5) .
Cut the tie straps and place wiring harness (5) aside.
Remove nut (2) and bolt (3) .
Remove refrigerant compressor (1) .Installation Procedure
Illustration 3 g00847221
Install refrigerant compressor (1) .
Install bolt (3) and nut (2) .
Install the belt.
Illustration 4 g00847243
Connect electrical connector (5) .
Install new O-ring seals in the two hose assemblies (4) .
Connect two hose assemblies (4) to refrigerant compressor (1) .
Evacuate the air conditioner system. Charge the air conditioner system. The correct charge is 2.7 kg (6 lb). Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.End By:
Adjust the belt tension. Refer to Operation and Maintenance Manual, "Belts - Inspect/Adjust/Replace" for the machine that is being serviced.
Separate the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect" for the machine that is being serviced.


Parts decal EVINRUDE:

0438454
 
0438454 DECAL SET, Johnson
E40WREES, E45RCLEUC, E55RSLC, E55WREES, SE40RPB, SE40RPLT2, SE55RSLM2
0438520
 
0438520 DECAL SET, Johnson
E40WREES, E45RCLEUC, E55RSLC, E55WREES, SE40RPB, SE40RPLT2, SE55RSLM2
0285090
 
0285090 DECAL SET, Evinrude
E40WREES, E40WRLSSC, E55WREES, E55WRLSSC, SE40RPLT2, SE40RSLR, SE55RSLM2
0347091
 
0347091 *DECAL, Port & Stbd, comm, Jo.
E150WPLSSC, E40WRLSSC, E55WRLSSC
0345648
 
0345648 *DECAL, Rear, Jo.
E40WRLSSC, E55WRLSSC
0347082
 
0347082 *DECAL, Rear, Jo.
E40WRLSSC, E55WRLSSC
5000450
 
5000450 DECAL SET, Jo.
E40WRLSSC, E55WRLSSC
5000451
DECAL SET, Jo.
5000451 DECAL SET, Jo.
E40WRLSSC, E55WRLSSC
Back to top