0330705 DETENT, Shift lever EVINRUDE
E40WREES, E40WRLSIR, E40WRLSSC, E45RCCDS, E45RCCUC, E45RCE, E45RCEIA, E45RCENM, E45RCEOD, E45RCERE, E45RCESR, E45RCETB, E45RCLEDS, E45RCLEUC, E55RSLC, E55RSLG, E55RSLW, E55RWLCDC, E55RWLCOS, E55RWLCUC, E55RWLE, E55RWLEIA, E55RWLENM, E55RWLERE, E55RWL
DETENT
Price: query
Rating:
Compatible models:
E40WREES
E40WRLSIR
E40WRLSSC
E45RCCDS
E45RCCUC
E45RCE
E45RCEIA
E45RCENM
E45RCEOD
E45RCERE
E45RCESR
E45RCETB
E45RCLEDS
E45RCLEUC
E55RSLC
E55RSLG
E55RSLW
E55RWLCDC
E55RWLCOS
E55RWLCUC
E55RWLE
E55RWLEIA
E55RWLENM
E55RWLERE
E55RWLESR
E55RWLETB
E55WREES
E55WRLSIR
E55WRLSSC
M55RWLR
R45RCLR
SE40RPB
SE40RPH
SE40RPLT2
SE55RSLM2
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- SHIFT & THROTTLE LINKAGE » 0330705
E40WRLSSC, E40WRSSC, E40WRYSSC 2000
E45RCCDS, E45RCLCDS 1986
E45RCCUC, E45RCLCUC 1987
E45RCE, E45RCLE, E45WMLE 1989
E45RCEIA, E45RCLEIA, E45WMLEIA 1991
E45RCENM, E45RCLENM, E45WMLENM 1992
E45RCEOD, E45RCLEOD 1995
E45RCERE, E45RCLERE 1994
E45RCESR, E45RCLESR, E45WMLESR 1990
E45RCETB, E45RCLETB 1993
E45RCLEDS, HE45RCLEDS, SE45RSLH 1996
E45RCLEUC, HE45RCLEUC, SE45RSLB 1997
E55RSLC, HE55RSLC, SE55RSC, SE55RSLC, SE55RSYC 1997
E55RSLG 1995
E55RSLW, HE55RSLW, SE55RSLW, SE55RSW, SE55RSYW 1996
E55RWLCDC 1986
E55RWLCOS 1985
E55RWLCUC 1987
E55RWLE 1989
E55RWLEIA 1991
E55RWLENM 1992
E55RWLERE 1994
E55RWLESR 1990
E55RWLETB 1993
E55WREES, E55WRLEES, E55WRYEES 1999
E55WRLSIR, E55WRSIR, E55WRYSIR 2001
E55WRLSSC, E55WRSSC, E55WRYSSC 2000
M55RWLR 1988
R45RCLR, R45RCR 1988
SE40RPB, SE40RPLB, SE40RPYB 1997
SE40RPH, SE40RPLH, SE40RPYH 1996
SE40RPLT2, SE40RPT2, SE40RPYT2 1998
SE55RSLM2, SE55RSM2, SE55RSYM2 1998
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
4212-5
Fan Drive Bypass Command Status : Current Below Normal 291-5
Engine Cooling Fan Solenoid : Current Below Normal The Electronic Control Module (ECM) detects an open circuit in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid.
The code is logged.
4212-6
Fan Drive Bypass Command Status : Current Above Normal 291-6
Engine Cooling Fan Solenoid : Current Above Normal The ECM detects a short circuit to ground in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid.
The code is logged. The Electronic Control Module (ECM) monitors engine coolant temperature, intake manifold air temperature, and hydraulic oil temperature. The ECM monitors the sensors to determine the correct speed for the engine cooling fan.The ECM controls the speed of the fan by controlling the current to the engine fan control solenoid. The engine fan control solenoid controls the amount of pressure to the fan pump by allowing oil to bypass the fan pump. The fan pump drives the fan. When the ECM outputs minimum current to the engine fan control solenoid, less oil is bypassed. The fan pump will now drive the fan at a higher rpm. When the ECM outputs maximum current to the engine fan control solenoid, more oil is bypassed. The fan pump will now drive the fan at a lower rpm.If the ECM detects a system fault, the ECM provides minimum current to the solenoid. Minimum current ensures a maximum fan speed while the fault condition exists.An override is available with Cat® Electronic Technician (ET). An override allows the fan to be manually changed from the minimum to the maximum rpm.
Illustration 1 g06067719
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -6 code is active or logged.
Proceed to Test Step 2.
Result: A -5 code is active or logged.
Proceed to Test Step 3.
2. Check the Wiring for an Open Circuit
A. Remove the electrical power from the ECM.
B. Disconnect the connector for the engine fan control solenoid.
C. Restore the electrical power to the ECM.
D. Connect Cat ET.
E. Use Cat ET to perform the following test:
- "Fan Override"
E. Use Cat ET to monitor the following:
- Codes
F. Record any active codes.
H. Disable the "Fan Override".
Create a Short
Result: A -6 code remains active. There is a short circuit between the harness connector for the engine fan control solenoid and the ECM.
Repair: Repair or replace the connectors or wiring. Ensure that all the seals are properly in place and ensure that the connectors are coupled.
Verify that the repair eliminated the problem.
Result: A -6 code was active before disconnecting the connector. A -5 code became active after disconnecting the connector.
Repair: Replace the engine fan control solenoid.
Verify that the repair eliminated the problem.
3. Check the Wiring for a Short Circuit
A. Remove the electrical power from the ECM.
B. Fabricate a jumper wire that is long enough to create a short between the terminals of the connector for the engine fan control solenoid. Crimp connector pins to each end of the jumper wire.
C. Install the jumper wire between the following terminals on the wiring harness side of the connector:
- Terminal 1 (engine fan control solenoid) and Terminal 2 (solenoid return)
D. Restore the electrical power to the ECM.
E. Connect Cat ET.
F. Use Cat ET to perform the following test:
- "Fan Override"
G. Use Cat ET to monitor the following:
- Codes
H. Record any active codes.
J. Disable the "Fan Override".
K. Remove the jumper wire.
Create an Open
Result: The -5 code remains active with the jumper in place.
Repair: Repair or replace the connectors or wiring. Ensure that all the seals are properly in place and ensure that the connectors are coupled.
Verify that the repair eliminated the problem.
Result: A -6 code became active when the jumper wire is installed. A -5 code becomes active when the jumper wire is removed.
Repair: Replace the engine fan control solenoid.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).