0330706 DETENT, Shift lever EVINRUDE
E35AELCDE, E35AELCUD, E40AELCCS, E40ECDE, E40ECOB, E40ECUD, E50BECCS, E50BECDE, E50BECOB, E50BECUD, E60ELCOD
DETENT

Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
E35AELCUD, E35ARLCUD 1987
E40AELCCS, E40ARLCCS, E40ATLCCS, E40ECCS, E40ELCCS, E40RCCS, E40RLCCS, E40TECCS, E40TELCCS, E40TLCCS, E40TTLCCS 1988
E40ECDE, E40ELCDE, E40RCDE, E40RLCDE, E40TECDE, E40TELCDE, E40TLCDE 1986
E40ECOB, E40ELCOB, E40RCOB, E40RLCOB, E40TECOB, E40TELCOB 1985
E40ECUD, E40ELCUD, E40RCUD, E40RLCUD, E40TECUD, E40TLCUD 1987
E50BECCS, E50BELCCS, E50TELCCS, E50TLCCS 1988
E50BECDE, E50BELCDE, E50TELCDE, E50TLCDE 1986
E50BECOB, E50BELCOB, E50TELCOB, E50TLCOB 1985
E50BECUD, E50BELCUD, E50TELCUD, E50TLCUD 1987
E60ELCOD, E60TLCOD 1985
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
5576-2
Aftertreatment #1 Identification Number Module : Erratic, Intermittent, or Incorrect 3468-2
Aftertreatment #1 Identification Number Module : Erratic, Intermittent, or Incorrect The installed Clean Emissions Module (CEM) #1 is not a certified match with the engine.
The code is a confirmed emissions regulation violation. A financial penalty and/or legal action may result, if the problem is not corrected immediately. Do not operate the engine with the active fault.
Engine power is derated.
5576-8
Aftertreatment #1 Identification Number Module: Abnormal Frequency, Pulse Width, or Period 3468-8
Aftertreatment #1 Identification Number Module : Abnormal Frequency, Pulse Width, or Period Emissions do not conform to regulations. Do not continue to operate the engine with the active fault.
Engine power is derated.
5577-2
Aftertreatment #2 Identification Number Module : Erratic, Intermittent, or Incorrect 3469-2
Aftertreatment #2 Identification Number Module : Erratic, Intermittent, or Incorrect The installed Clean Emissions Module (CEM) #2 is not a certified match with the engine.
The code is a confirmed emissions regulation violation. A financial penalty and/or legal action may result, if the problem is not corrected immediately. Do not operate the engine with the active fault.
Engine power is derated.
5577-8
Aftertreatment #2 Identification Number Module: Abnormal Frequency, Pulse Width, or Period 3469-8
Aftertreatment #2 Identification Number Module : Abnormal Frequency, Pulse Width, or Period Emissions do not conform to regulations. Do not continue to operate the engine with the active fault.
Engine power is derated.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A code is active or logged.
Proceed to Test Step 2.
Illustration 1 g02896037
Typical Clean Emissions Module (CEM) identification plate
Table 3
Troubleshooting Test Steps Values Results
2. Manually Enter the Aftertreatment Identification Information
The Clean Emissions Module (CEM) identification plate is on the electronics panel.
Factory Passwords are required for this procedure.
A. Confirm that a certified CEM is installed on the engine.
Contact your local Cat dealer for a list of approved CEM configurations for your engine.
B. Record the affected CEM serial number and the configuration group from the CEM Identification Plate.
C. Verify that the affected CEM is a certified match with the engine.
Certified Match
Result: The affected CEM is a certified match with the engine.
Proceed to Test Step 3.
Result: The affected CEM is not a certified match for the engine.
Repair: Remove the affected CEM and replace the affected CEM with a certified match for the engine. Refer to Disassembly and Assembly for additional information. When the new CEM is installed, the"Aftertreatment Identification Number Module" will begin communicating with the ECM and the code will be cleared.
When determining if a CEM is a certified match:
The engine ECM will only communicate with the CEM if the total lifetime hours of the engine are less than 100. If the hours are greater than 100, the information from the CEM identification plate must be programmed into the ECM by using Cat ET.
If the problem is not resolved, proceed to Test Step 3.
Illustration 2 g03733735
Typical "Aftertreatment Configuration"
Table 4
Troubleshooting Test Steps Values Results
3. Program the Aftertreatment Identification Number
A. Connect Cat ET.
B. Navigate to the "Aftertreatment Configuration" in the affected "Engine Aftertreatment Controller" page.
C. Program the required "Factory Installed Aftertreatment Identification Number" with the serial number from the CEM Identification Plate.
Identification Number
Result: The code is automatically cleared.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts detent EVINRUDE:
0322636
0322636 DETENT,Shifter
50902C, 55772D, 55874S, 70773S, 70873C, 70973R, E35AELCDE, E35AELCUD, E40AELCCS, E40ECDE, E40ECOB, E40ECRM, E40ECUD, E48ESLCCC, E48ESLCCC, E48ESLCUS, E48ESLCUS, E50BECCS, E50BECDE, E50BECIC, E50BECNR, E50BECOB, E50BECRM, E50BECTA, E50BECUD, E50ECSR,
0327043
0327043 DETENT, Primer pump
E35AELCDE, E35AELCUD, E40AELCCS, E40ECDE, E40ECOB, E40ECRM, E40ECUD, E40WREES, E40WRLSIR, E40WRLSSC, E45RCCDS, E45RCCUC, E45RCE, E45RCEIA, E45RCENM, E45RCEOD, E45RCERE, E45RCESR, E45RCETB, E45RCLEDS, E45RCLEUC, E50BECCS, E50BECDE, E50BECIC, E50BECUD,
0330701
0330701 DETENT, Shifter
E40AELCCS, E40DELSDA, E40DELSOR, E40DELSRC, E40DPLAAA, E40DPLABA, E40DPLIIS, E40DPLINC, E40DPLISD, E40DPLISF, E40DPLSCB, E40DPLSDA, E40DPLSEE, E40DPLSOR, E40DPLSRC, E40DPLSUM, E40DRLAAA, E40DRLABA, E40DRLIIS, E40DRLINC, E40DRLISD, E40DRLISF, E40DRLSC