0323534 EVINRUDE DRIVESHAFT, Long 5 INCH LONGER PARTS


0323534 DRIVESHAFT, Long 5 INCH LONGER PARTS EVINRUDE 25802C DRIVESHAFT
0323534 DRIVESHAFT, Long 5 INCH LONGER PARTS EVINRUDE
Rating:
8

Buy DRIVESHAFT, Long 5 INCH LONGER PARTS 0323534 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 15
 

Compatible models:

25802C   EVINRUDE

BRP EVINRUDE entire parts catalog list:

25802C, 25803C, 25852C, 25853C, 35802R, 35803R, 35852R, 35853R 1978

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
1180-3
Engine Turbocharger 1 Turbine Inlet Temperature : Voltage Above Normal 3908-3
Engine Turbocharger #1 Turbine Intake Temperature Sensor : Voltage Above Normal If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
The code is logged.
1180-4
Engine Turbocharger 1 Turbine Inlet Temperature : Voltage Below Normal 3908-4
Engine Turbocharger #1 Turbine Intake Temperature Sensor : Voltage Below Normal If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
The code is logged.
1180-8
Engine Turbocharger 1 Turbine Inlet Temperature : Abnormal Frequency, Pulse Width, or Period 3908-8
Engine Turbocharger #1 Turbine Intake Temperature Sensor : Abnormal Frequency, Pulse Width, or Period If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
The code is logged.
1181-3
Engine Turbocharger 2 Turbine Inlet Temperature : Voltage Above Normal 3909-3
Engine Turbocharger #2 Turbine Intake Temperature Sensor : Voltage Above Normal If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
The code is logged.
1181-4
Engine Turbocharger 2 Turbine Inlet Temperature : Voltage Below Normal 3909-4
Engine Turbocharger #2 Turbine Intake Temperature Sensor : Voltage Below Normal If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
The code is logged.
1181-8
Engine Turbocharger 2 Turbine Inlet Temperature : Abnormal Frequency, Pulse Width, or Period 3909-8
Engine Turbocharger #2 Turbine Intake Temperature Sensor : Abnormal Frequency, Pulse Width, or Period If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
The code is logged.
Illustration 1 g06323402
Schematic of the PWM sensors for the sensor signal circuit
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -3 code is active or logged.
Proceed to Test Step 2.
Result: A -4 code is active or logged.
Proceed to Test Step 3.
Result: A -8 code is active or logged.
Proceed to Test Step 5.
2. Create a Short at the Sensor Connector
A. Remove electrical power from the engine.
B. Disconnect the sensor with the active -3 code.
C. Install the jumper wire between the following terminals at the sensor connector:
- Pin 2 (sensor return) and Pin 3 (sensor signal)
D. Connect Cat ET.
E. Use Cat ET to monitor the following:
- -4 code
F. Remove electrical power from the engine.
Create a Short
Result: A -4 code became active.
Repair: The wiring harness is OK. Replace the sensor.
Verify that the repair eliminated the problem.
Result: A -4 code did not become active.
Proceed to Test Step 4.
3. Create an Open at the Sensor Connector
A. Remove electrical power from the engine.
B. Disconnect the sensor with the active -4 code.
C. Connect Cat ET.
D. Use Cat ET to monitor the following:
- -3 code
E. Remove electrical power from the engine.
Create an Open
Result: A -3 code became active.
Repair: The wiring harness is OK. Replace the sensor.
Verify that the repair eliminated the problem.
Result: A -3 code did not become active.
Proceed to Test Step 4.
4. Check the 8 VDC Supply Voltage at the Sensor Connector
A. Apply electrical power to the engine.
B. Measure the voltage at the following pin locations of the affected sensor connector:
- Pin 1 and Pin 2
C. Reconnect the sensor.
Supply Voltage
Result: The supply voltage is approximately 8.0 0.2 VDC
Proceed to Test Step 8.
Result: The supply voltage is not approximately 8.0 0.2 VDC.
Repair: There is a short in the wiring harness to the battery. Repair or replace the wiring harness.
If the problem is not resolved, proceed to Test Step 5.
5. Check the PWM Circuit for an Open
A. Remove electrical power from the engine.
B. Disconnect the sensor with the active -8 code.
C. Disconnect the J2 connector


Parts driveshaft EVINRUDE:

0323261
 
0323261 DRIVESHAFT, Std.
25802C, 25904R, E25RCSA, E35ECIG, E35ECND, E35ECSM, E35ECTS
0323262
 
0323262 DRIVESHAFT, Long
25802C, 25904R, E25RCSA, E35ECIG, E35ECND, E35ECSM, E35ECTS
Back to top