0283134 ENGINE COVER ASSY., 200 EVINRUDE
E200STLCDR, E225PTLCDA
ENGINE
Price: query
Rating:
Compatible models:
E200STLCDR
E225PTLCDA
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- ENGINE COVER - EVINRUDE - 200STL » 0283134
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
168-3
Battery Potential / Power Input #1 : Voltage Above Normal 168-3
Electrical System Voltage : Voltage Above Normal The Electronic Control Module (ECM) detects voltage that is above the acceptable value.
168-4
Battery Potential / Power Input #1 : Voltage Below Normal 168-4
Electrical System Voltage : Voltage Below Normal The ECM detects voltage that is below the acceptable value.
3218-11
Engine Exhaust #1 Gas Sensor #1 Power In Range : Other Failure Mode 3781-11
Aftertreatment #1 Intake NOx Level Sensor Power Supply : Other Failure Mode The NOx sensor has detected that the power supply is not correct.
3228-11
Aftertreatment #1 Outlet Gas Sensor Power In Range : Other Failure Mode 3619-11
Aftertreatment #1 Outlet NOx Level Sensor Power Supply : Other Failure Mode The NOx sensor has detected that the power supply is not correct.
3257-11
Engine Exhaust #2 Gas Sensor #1 Power In Range : Other Failure Mode 5354-11
Aftertreatment #2 Intake NOx Level #1 Sensor Power Supply : Other Failure Mode The NOx sensor has detected that the power supply is not correct.
3267-11
Aftertreatment #2 Outlet Gas Sensor Power In Range : Other Failure Mode 5353-11
Aftertreatment #2 Outlet NOx Level #1 Sensor Power Supply : Other Failure Mode The NOx sensor has detected that the power supply is not correct.
3360-3
Aftertreatment #1 DEF Controller : Voltage Above Normal 3820-3
Aftertreatment #1 DEF Controller #1 : Voltage Above Normal The Diesel Exhaust Fluid Control Unit (DCU) has detected that the voltage is above the acceptable threshold.
3360-4
Aftertreatment #1 DEF Controller : Voltage Below Normal 3820-4
Aftertreatment #1 DEF Controller #1 : Voltage Below Normal The DCU has detected that the voltage is below the acceptable threshold.
4450-3
Aftertreatment #2 DEF Controller : Voltage Above Normal 4577-3
Aftertreatment #2 DEF Controller #1 : Voltage Above Normal The DCU has detected that the voltage is above the acceptable threshold.
4450-4
Aftertreatment #2 DEF Controller : Voltage Below Normal 4577-4
Aftertreatment #2 DEF Controller #1 : Voltage Below Normal The DCU has detected that the voltage is below the acceptable threshold.
7538-3
Aftertreatment #1 DEF Controller #2 : Voltage Above Normal 4797-3
Aftertreatment #1 DEF Controller #2 : Voltage Above Normal The DCU has detected that the voltage is above the acceptable threshold.
7538-4
Aftertreatment #1 DEF Controller #2 : Voltage Below Normal 4797-4
Aftertreatment #1 DEF Controller #2 : Voltage Below Normal The DCU has detected that the voltage is below the acceptable threshold.
7539-3
Aftertreatment #2 DEF Controller #2 : Voltage Above Normal 4798-3
Aftertreatment #2 DEF Controller #2 : Voltage Above Normal The DCU has detected that the voltage is above the acceptable threshold.
7539-4
Aftertreatment #2 DEF Controller #2 : Voltage Below Normal 4798-4
Aftertreatment #2 DEF Controller #2 : Voltage Below Normal The DCU has detected that the voltage is below the acceptable threshold.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -3 code is active or logged.
Proceed to Test Step 2.
Result: A -4 code is active or logged.
Proceed to Test Step 3.
2. Check the Charging Circuit
Charging Circuit
Result: The charging system is OK.
Proceed to Test Step 3.
Result: The charging system is NOT OK.
Repair: There is a problem with the charging system. Refer to Special Instruction, REHS0354, "Charging System Troubleshooting" for additional information.
Verify that the repair eliminated the problem.
3. Inspect the Batteries
A. Charge the batteries, if necessary. Refer to Special Instruction, SEHS7633, "Battery Test Procedure" for additional information.
B. Load-test the batteries. Refer to Special Instruction, SEHS9249, "Use of 4C-4911 Battery Load Tester for 6, 8 V and 12 V Lead Acid Batteries" for additional information.
Batteries
Result: The batteries pass the load test. The measured voltage is between 11.5 VDC and 13.5 VDC for a 12 V system. The measured voltage is between 23.0 VDC and 27.0 VDC for a 24 V system.
Repair: Verify that the "System Operating Voltage Configuration" is correctly configured in the Engine ECM configuration parameters.
Verify that the repair eliminated the problem.
Result: The battery voltage is low or the battery did not pass the load test.
Repair: Repair or replace the batteries.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts engine EVINRUDE:
0282617
0283129
0282911
0398016
0395933
0396799
0397924
0583047