0446213 EVINRUDE ENGINE COVER, Lower, port


0446213 ENGINE COVER, Lower, port EVINRUDE BE10FAEDC, BE8FRBEDC ENGINE
0446213 ENGINE COVER, Lower, port EVINRUDE
Rating:
88

Buy ENGINE COVER, Lower, port 0446213 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 2
 

Compatible models:

BRP EVINRUDE entire parts catalog list:

BE10FAEDC, BE10FCLEDC, BE10FWEDC, BE10FWLEDC, HE10FDEDC, HE10FDLEDC, HE10FELEDC, HE10FTEDC, HE10FTLEDC 1996
BE8FRBEDC, BE8FRBLEDC, BE8FRBXEDC, E8FREDC, E8FRXEDC, HE8FREDC, HE8FRLEDC 1996

Information:

Through Flow DPF
The through flow DPF uses passive regeneration in order to remove the soot from the DPF. Passive regeneration is a chemical reaction within the system. Normal operation of the engine creates enough heat for a chemical reaction in order to regenerate the DPF. The regeneration occurs automatically during normal engine operation. This system uses an amount of active regeneration in order to ensure that soot cannot exit the DPF. The through flow DPF will not require manual cleaning.For a typical view of the through flow DPF, refer to this Operation and Maintenance Manual, "Sensors and Electrical Components (Aftertreatment)"Wall Flow DPF
The wall flow DPF uses passive regeneration and active regeneration in order to remove the soot from the DPF. The ash is trapped within the DPF and must be removed by a manual cleaning process Refer to Operation and Maintenance Manual , "Diesel Particulate Filter- Clean".For a typical view of the wall flow DPF, refer to this Operation and Maintenance Manual, "Sensors and Electrical Components (Aftertreatment)"Regeneration Indicators
Five indicators can be affected by the DPF regeneration. these indicators are, Regeneration Active, DPF, Disable Regeneration, Amber, or Yellow Warning Indicator and Red Stop Indicator.
Regeneration Active - This indicator will illuminate during active regeneration. The indicator shows that elevated exhaust temperatures are possible. The indicator will be turned off when regeneration is complete.
DPF - This indicator provides a general indication of the soot load. The indicator is off when the soot load is normal.
Disable Regeneration - This indicator is illuminated whenever the disable switch is activated. Modes of Regeneration
Automatic regeneration
Forced regenerationAutomatic regeneration - Automatic regeneration will occur when the level of soot reaches the trigger point that is set in the ECM. The engine can operate normally during an automatic regeneration.Manual - A manual regeneration is initiated by pressing the regeneration switch. A forced regeneration can only be performed after the soot load has illuminated the DPF indicator . A forced regeneration will only be required if the automatic regeneration has not been completed. This situation can be due to either the disable switch being operated or the duty cycle of the engine.Note: In some applications the engine safety interlocks will need to be in place before a forced regeneration can occur.Regeneration Switch
Note: The regeneration switch is a three position switch. Some OEMs may use other means of activating a forced regeneration such as touch screen interfaces.
Force Regeneration - Press in the top of the switch for 2 seconds in order to begin regeneration.
Disable Regeneration - Press in the bottom of the switch for 2 seconds in order to disable regeneration. Press again in order to return to automatic mode. Note: Turning the keyswitch to the OFF position will remove the disable regeneration input and return the engine to automatic mode of regeneration.Note: The MIDDLE position of the regeneration switch is the default position for automatic regeneration.Note: You may return to normal operation at any point during a regeneration.Regeneration System Warning Indicators
Some applications may also have an audible warning installed.
Table 1
Indicator Operation    
During passive regeneration no indicator will be illuminated    
Aftertreatment Indicator     Aftertreatment Indicator State     Warning Indicator     Warning Indicator State     Description     Action Required    
Regeneration Active indicator     On Solid     None     None     Regeneration is activated. The indicator will stay illuminated during regeneration.     None    
-    
DPF Indicator     On Solid     None     None     The indicator provides a general indication of the soot load. The indicator is off when the soot load is normal.     A regeneration is required. In automatic mode the ECM will decide when to allow the active regeneration.
If the DPF indicator stays illuminated allow a manual regeneration without interruption. An uninterrupted active regeneration will reset the DPF indicator.    
-    
DPF Indicator     On Solid     Amber indicator     Flashing     The indicator indicates that the soot load has increased.
The engine will derate.     A manual regeneration is required. Perform a manual regeneration, or a service regeneration will be required.    
-    
DPF Indicator     On Solid     Amber indicator     Flashing     The flashing warning indicator and red stop indicator indicates that the engine has continued to be operated while a regeneration is required.
The engine will be derated and the engine should be shut down immediately.     Once the engine enters into shutdown mode, you must contact your Cat dealer.
Your dealer will need to perform a service level regeneration. The DFP may need to be replaced.    
-     -     Red indicator (STOP)     On Solid    Note: Amber or yellow warning indicator can be used as a diagnostic lamp. For more information refer to this Operation and Maintenance Manual, "Diagnostic Lamp".Regeneration Operation
Regeneration will require the following conditions:Automatic Regeneration
In order for an automatic regeneration to take place the engine must be at operating temperature.Turning the keyswitch to the OFF position during a regeneration will stop the regeneration. An interrupted regeneration will not remove the soot from the DPF and will waste fuel.Wall Flow DPF Only
The engine Revs Per Minute (RPM) must be above 1200 RPM for the regeneration to start. Normal operation


Parts engine EVINRUDE:

0445040
 
0445040 ENGINE COVER ASSY.
BE10FAEDC, BE10FAEUR, BE8FRBECA, BE8FRBEDC, BE8FRBEUR, E10FOECA
0445088
 
0445088 ENGINE COVER ASSY.
BE10FAEDC, BE10FAEUR, BE8FRBEDC, BE8FRBEUR
0445029
 
0445029 ENGINE COVER ASSY.
BE10FAEDC, BE10FAEUR, BE8FRBECA, BE8FRBEDC, BE8FRBEUR, E10FOECA
0445041
 
0445041 ENGINE COVER ASSY.
BE10FAEDC, BE10FAEUR, BE8FRBECA, BE8FRBEDC, BE8FRBEUR, E10FOECA
0445089
 
0445089 ENGINE COVER ASSY.
BE10FAEDC, BE8FRBEDC
0445042
 
0445042 ENGINE COVER ASSY.
BE10FAEDC, BE10FAEUR, BE8FRBECA, BE8FRBEDC, BE8FRBEUR, E10FOECA
0446389
 
0446389 ENGINE COVER, Lower, port
BE10FAEDC, BE8FRBEDC
0446214
 
0446214 ENGINE COVER, Lower, stbd.
BE10FAEDC, BE8FRBEDC