0325661 EVINRUDE EXHAUST HOUSING, Outer


0325661 EXHAUST HOUSING, Outer EVINRUDE E115MLCIH, E140MLCIH, E150TRLCIA, E175TRLCIM, E200TRLCIB, E235TRLCIB, E90MLCIH EXHAUST
0325661 EXHAUST HOUSING, Outer EVINRUDE
Rating:
88

Buy EXHAUST HOUSING, Outer 0325661 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 15
 

BRP EVINRUDE entire parts catalog list:

E115MLCIH, E115MLCIM, E115TLCIH, E115TLCIM, E115TXCIH, E115TXCIM 1981
E140MLCIH, E140MLCIM, E140TRLCIH, E140TRLCIM, E140TRXCIH, E140TRXCIM 1981
E150TRLCIA, E150TRLCIH, E150TRXCIA, E150TRXCIH 1981
E175TRLCIM, E175TRXCIH, E175TRXCIM 1981
E200TRLCIB, E200TRLCIH, E200TRXCIB, E200TRXCIH 1981
E235TRLCIB, E235TRLCIH, E235TRXCIB, E235TRXCIH 1981
E90MLCIH, E90MLCIM, E90TLCIH, E90TLCIM, E90TXCIH, E90TXCIM 1981

Information:


Table 1
Diagnostic Codes Table
Code and Description Conditions which Generate this Code System Response
E085(1) Engine Shutdown Overridden The engine's Electronic Control Module (ECM) detects ground on the input for the maintenance clear switch. If an engine derate or an engine shutdown is active, the derate or the shutdown will be overridden.
The code is logged.
E097(1) Engine Derate Overridden System OperationIf full engine power is needed, the maintenance clear switch allows the user to override an engine derate or an engine shutdown. The wire for the maintenance clear switch is routed from the ECM to the customer connector. The wire is then routed to a customer supplied switch.
Illustration 1 g01383504
Typical schematic
Illustration 2 g01383505
P2 ECM connector
(P2-19) Maintenance clear switch
Illustration 3 g01383506
Customer connector
(Terminal 17) Maintenance clear switch
Illustration 4 g01234146
Location of ECM connectors
Test Step 1. Check for an "Active" Event Code
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Turn the main disconnect switch to the ON position.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if one of the following event codes is active:
E085
E097Expected Result:A E085 event code or a E097 event code is active.Results:
OK - A E085 event code or a E097 event code is active. Proceed to Test Step 2.
Not OK - An event code is not active but a problem is suspected with the circuit for the maintenance clear switch. Proceed to Test Step 3.Test Step 2. Check the Position of the Maintenance Clear Switch
Visually check the position of the maintenance clear switch. Expected Result:The maintenance clear switch is in the ON position.Results:
OK - The maintenance clear switch is in the ON position.Repair: Determine the reason that the maintenance clear switch is in the ON position.STOP
Not OK - The maintenance clear switch is in the OFF position. Proceed to Test Step 3.Test Step 3. Check the Signal Wire between the Maintenance Clear Switch and the ECM
Disconnect the wire L460-YL(Yellow) from the maintenance clear switch.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if one of the following event codes is active:
E085
E097Expected Result:A E085 event code or a E097 event code is active.Results:
OK - A E085 event code or a E097 event code is active. The short circuit is in the wire between the maintenance clear switch and the ECM. Proceed to Test Step 4.
Not OK - An event code is not active.Repair: The short circuit is most likely in the maintenance clear switch. Replace the switch.STOPTest Step 4. Check the Signal Wire between the Customer Connector and the ECM
Disconnect the wire L460-YL(Yellow) from terminal 17 of the customer connector.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if one of the following event codes is active:
E085
E097Expected Result:A E085 event code or a E097 event code is active.Results:
OK - A E085 event code or a E097 event code is active. The short circuit is in the wire between the customer connector and the ECM. Proceed to Test Step 5.
Not OK - An event code is not active.Repair: The short circuit is between the maintenance clear switch and the customer connector. Replace the wire or repair the wire.STOPTest Step 5. Check the Signal at the ECM
Disconnect the wire L460-YL(Yellow) from the P2-19 ECM connector.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if one of the following event codes is active:
E085
E097Expected Result:An E085 event code or a E097 event code is active.Results:
OK - A E085 event code or a E097 event code is active. The short circuit is in the ECM.Repair: Replace the ECM. Refer to Troubleshooting, "ECM - Replace".STOP
Not OK - An event code is not active.Repair: The short circuit is between the customer connector and the ECM. Replace the wire or repair the wire.STOP


Parts exhaust EVINRUDE:

0320839
 
0320839 EXHAUST HOUSING,Inner lower
100990S, 115790S, 115890C, 150840S, 150940C, 175740S, 200640S, C155WTLM, E100MLCSC, E100STLCEM, E100WTLZ, E110MLCEM, E115MLCIH, E115MLCSA, E120TLCEM, E125ESXW, E140CXCEC, E140MLCIH, E140MLCSA, E150CXCEM, E150CXESB, E150TRLCIA, E150TRLCSF, E155WTLZ, E
0320838
EXHAUST HOUSING,Inner lower
0320838 EXHAUST HOUSING,Inner lower
100990S, 115790S, 115890C, 150840S, 150940C, 175740S, 200640S, C155WTLM, E100MLCSC, E100STLCEM, E100WTLZ, E110MLCEM, E115MLCIH, E115MLCSA, E120TLCEM, E125ESXW, E140CXCEC, E140MLCIH, E140MLCSA, E150CXCEM, E150CXESB, E150STLCEM, E150STLESB, E150TRLCIA,
0323468
 
0323468 EXHAUST MANIFOLD, 140 HP
100990S, 115890C, BE115TLEDA, E100MLCSC, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E110MLCCA, E110MLCDC, E110MLCEM, E110MLCUR, E112TSLEDR, E112TSLEDR, E112TSLEOC, E112TSLEOC, E112TSLERS, E115JKLEOC, E115JKLER
0323549
 
0323549 EXHAUST HOUSING, Outer
100990S, 115890C, 150840S, 150940C, E100MLCSC, E115MLCIH, E115MLCSA, E140MLCIH, E140MLCSA, E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM, E85MLCSA, E90MLCIH
0323550
 
0323550 EXHAUST HOUSING, Outer
100990S, 115890C, 150840S, 150940C, E100MLCSC, E115MLCIH, E115MLCSA, E140MLCIH, E140MLCSA, E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM, E85MLCSA, E90MLCIH
0392000
EXHAUST FILLER BLOCK REPLACEMENT KIT
0392000 EXHAUST FILLER BLOCK REPLACEMENT KIT
BE115TLEDA, E100MLCSC, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E110MLCCA, E110MLCDC, E110MLCEM, E110MLCUR, E112TSLEDR, E112TSLEDR, E112TSLEOC, E112TSLEOC, E112TSLERS, E115JKLEOC, E115JKLERS, E115JLEIE, E115
0325662
 
0325662 EXHAUST HOUSING, Outer
E115MLCIH, E140MLCIH, E150TRLCIA, E175TRLCIM, E200TRLCIB, E235TRLCIB, E90MLCIH
0322719
 
0322719 EXHAUST HOUSING, Inner upper
E150TRLCIA, E175TRLCIM, E200TRLCIB, E235TRLCIB
Back to top