0389221 EVINRUDE EXTENSION KIT ASSY -5 INCH 5" LONGER PARTS


0389221 EXTENSION KIT ASSY -5 INCH 5" LONGER PARTS EVINRUDE 4806E EXTENSION
0389221 EXTENSION KIT ASSY -5 INCH 5" LONGER PARTS EVINRUDE
Rating:
63

Buy EXTENSION KIT ASSY -5 INCH 5" LONGER PARTS 0389221 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 38922
 

Compatible models:

4806E   EVINRUDE

BRP EVINRUDE entire parts catalog list:

4806E, 4836E, 4837E 1978

Information:

Cross-Reference Tables
Portions of this material are reprinted with permission from SAE J1939DA_201607© 2016 SAE International. SAE International is not responsible for any use or translation of this material, in whole or in part. Please contact SAE International to obtain a complete copy of SAE J1939DA_201607, the official definitive source of this standard.
Table 1
Cross-Reference for Event Codes
Flash Codes EID/FMI Codes SPN/FMI Codes Description of Code
35 004 0190-16 Engine Overspeed Shutdown
63 005 0094-15 Fuel Filter Restriction Derate
63 006 0094-16 Fuel Filter Restriction Shutdown
61 015 0110-16 High Engine Coolant Temperature Derate
61 016 0110-00 High Engine Coolant Temperature Shutdown
61 017 0110-15 High Engine Coolant Temperature Warning
64 025 0172-16 High Inlet Air Temperature Derate
64 027 0172-15 High Inlet Air Temperature Warning
46 039 0100-18 Low Engine Oil Pressure Derate
46 040 0100-01 Low Engine Oil Pressure Shutdown
62 057 0111-18 Low Engine Coolant Level Derate
62 058 0111-01 Low Engine Coolant Level Shutdown
62 059 0111-17 Low Engine Coolant Level Warning
63 095 0094-00 Fuel Filter Restriction Warning
63 096 0094-00 High Fuel Pressure
46 100 0100-17 Low Engine Oil Pressure Warning
35 190 0190-00 Engine Overspeed Warning
N/A 443(1) 1835-15 High Auxiliary Pressure Warning
1835-16 High Auxiliary Pressure Derate
1835-00 High Auxiliary Pressure Shutdown
445(1) 1836-15 High Auxiliary Temperature Warning
1836-16 High Auxiliary Temperature Derate
1836-00 High Auxiliary Temperature Shutdown
(1) Caterpillar Electronic Technician (ET) will display the number 1, 2, or 3 after the event code to designate a warning, a derate, or a shutdown.Active of Event Codes
An event code represents a problem with engine operation. Correct the problem as soon as possible.Event codes are listed in ascending numerical order. The code with the lowest number is listed first.Illustration 1 is an example of the operating range of a temperature sensor. Do not use the Illustration to troubleshoot temperature sensors.
Illustration 1 g01138880
Example of the typical operating range of a temperature sensor
(1) This area represents the normal operating range of the parameter. The normal output voltage of the sensor is between 0.2 VDC and 4.2 VDC.
(2) In this area, the temperature above 107 °C (225 °F) is higher than normal. The output voltage of the sensor will generate an event code. The sensor does not have an electronic problem.
(3) In these areas, the output voltage of the sensor is too high or too low. The voltage is outside of the normal range. The electronic problem will generate a diagnostic code. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code" for additional information on diagnostic codes.Events are represented in two formats. In the first format, the "E" means that the code is an event code. The "XXX" represents a numeric identifier for the event code. This is followed by a description of the code. If a warning, a derate, or a shutdown is applicable, the numeric identifiers are different. Refer to the following example:
E004 Engine Overspeed ShutdownIn the second format, the "E" means that the code is an event code. The "XXX-X" represents a numeric identifier for the event code. The fourth "X" identifies the event as a warning, a derate, or a shutdown. This is followed by a description of the code. Refer to the following example:
E360-1 Low Oil Pressure Warning
E360-2 Low Oil Pressure Derate
E360-3 Low Oil Pressure ShutdownThe definition for a warning, a derate, and a shutdown are defined below:Warning - This condition represents a serious problem with engine operation. However, this condition does not require a derate or a shutdown.Derate - For this condition, the Electronic Control Module (ECM) reduces the engine's power to help prevent possible engine damage.Shutdown - For this condition, the ECM shuts down the engine to help prevent possible engine damage.Logged Event Codes
When the ECM generates an event code, the ECM logs the code into permanent memory. The ECM has an internal diagnostic clock. The ECM will record the following information when an event code is generated:
The hour of the first occurrence of the code
The hour of the last occurrence of the code
The number of occurrences of the codeLogged events are listed in chronological order. The most recent event code is listed first.This information can be helpful for troubleshooting intermittent problems. Logged codes can also be used to review the performance of the engine.Clearing Event Codes
A code is cleared from memory when one of the following conditions occur:
The code does not recur for 100 hours.
A new code is logged and there are already ten codes in memory. In this case, the oldest code is cleared.
The service technician manually clears the code.Always clear logged event codes after investigating and correcting the problem which generated the code.


Parts extension EVINRUDE:

0310355
 
0310355 EXTENSION,Gearcase 5" 5" LONGER PARTS
3802A, 4006E, 4106D, 4206S, 4306C, 4406R, 4506A, 4606M, 4706B, 4806E, 4902B, 4904D, 5802B, E4RLCSS, E4WCIC, E4WCNR
Back to top