0349649 *FOAM BARRIER, Rear - Port EVINRUDE
E200FCXSNF, E200FCXSOE, E200FCXSRB, E200FCXSTM, E200FHLSOR, E200FHLSRC, E200FPLSNF, E200FPLSOE, E200FPLSRB, E200FPLSTM, E225FCXSNF, E225FCXSOE, E225FCXSRB, E225FCXSTM, E225FHLSOB, E225FHLSRM, E225FHLSTA, E225FPLSOE, E225FPLSRB, E250FCXSNF, E250FCXSOB
FOAM
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
- LOWER ENGINE COVER » 0349649
E200FCXSRB 2004
E200FCXSTM, E200FHLSTS 2003
E200FHLSOR 2004,2005
E200FHLSRC 2004
E200FPLSNF, E200FPXSNF 2002
E200FPLSOE, E200FPXSOE, E200FSLSOE 2004,2005
E200FPLSRB, E200FPXSRB, E200FSLSRB 2004
E200FPLSTM, E200FPXSTM, E200FSLSTM 2003
E225FCXSNF, E225FCZSNF, E225FHLSNF, E225FPLSNF, E225FPXSNF, E225FPZSNF 2002
E225FCXSOE, E225FCZSOE 2004,2005
E225FCXSRB, E225FCZSRB 2004
E225FCXSTM, E225FCZSTM, E225FPLSTM, E225FPXSTM, E225FPZSTM 2003
E225FHLSOB, E225FHXSOC 2004,2005
E225FHLSRM, E225FHXSRS 2004
E225FHLSTA 2003
E225FPLSOE, E225FPXSOE, E225FPZSOE 2004,2005
E225FPLSRB, E225FPXSRB, E225FPZSRB 2004
E250FCXSNF, E250FCZSNF, E250FPZSNF 2002
E250FCXSOB, E250FCZSOB 2004,2005
E250FCXSRM, E250FCZSRM 2004
E250FCXSTA, E250FCZSTA, E250FPLSTR, E250FPXSTA, E250FPZSTA 2003
E250FPLSOM, E250FPXSOB, E250FPZSOB 2004,2005
E250FPLSRA, E250FPXSRM, E250FPZSRM 2004
E250FPXSNF 2002
Information:
Table 1
Typical Configuration Parameters
Parameter Programmability
Air shutoff (ON/OFF) Yes
Crank duration Yes
Crank terminate speed Yes
Cold cylinder cutout Yes
Cooldown speed Yes
Droop (percent) Yes
ECM serial number No
Engine acceleration rate Yes
Engine cooldown duration Yes
Engine cooling system configuration (1) Yes
Engine prelube duration Yes
Engine rated speed Software dependent
Engine rotation Software dependent
Engine serial number Yes
Equipment ID Yes
Ether control (ON/OFF) Yes
Fuel correction factor Yes
Fuel ratio control offset Yes
Low idle speed Yes
Maximum number of crank cycles Yes
Personality Module Part Number Software dependent
Personality module release date Software dependent
Rated fuel position Yes
Total fuel Yes
Total hours Yes
Total tattletale No
(1) Jacket water aftercooling or separate circuit aftercoolingThe following parameters are programmed at the factory to zero:
"Crank Duration"
"Maximum Number Of Crank Cycles"The zero settings prevent the Electronic Control Module (ECM) from engaging the starting motors. The settings must be reprogrammed before the engine will crank.Ensure that the "Air Shutoff" and the "Ether Control" parameters are "Enabled/ON" (if equipped) . If the engine does not have these options, ensure that these two parameters are "DISABLED/OFF".If the engine is equipped with Prelube, the "Engine Prelube Duration" must be programmed to a value that is greater than zero seconds. Otherwise, the prelube pump will not cycle. If the engine is not equipped with Prelube, the parameter must be programmed to zero.The engine will have either jacket water aftercooling or separate circuit aftercooling. The correct configuration of the aftercooling system must be programmed.No password is required for programming a new ECM during the first 100 hours of service life. Free configuration feature enables the customer to tailor the programmable setpoints to the requirements of the installation during the 100 hours. Exceptions are "Fuel Limit" and "Personality Module Mismatch".Air Shutoff (If Equipped)
The air shutoff uses a moving plate to block inlet air to the aftercooler. The engine stops because of the restricted air supply to the combustion chamber. The air shutoff only actuates for the following conditions:
The Emergency Stop button is pressed.
An overspeed shutdown occurs.Both of the air shutoffs must be reset before the engine can be restarted.
Illustration 1 g00751561
Reset knob for the air shutoff
To reset the air shutoff, turn the reset knob to the "OPEN" position.Ensure that both of the air shutoffs are reset.Cold Cylinder Cutout
Note: This feature can be enabled or disabled with a Cat ET.The Cold Cylinder Cutout feature provides the following benefits:
Reduction of white smoke during cold starting
Reduction of the duration of advanced timing (cold mode)
Reduction of ether injectionThe ECM automatically turns off one electronic unit injector at a time during the following occurrences:
Cold start-up
Extended time at low idleThe ECM monitors the change of the fuel rack to determine if a cylinder is firing. If the cylinder is firing, the ECM activates the electronic unit injector. If the cylinder is not firing, the electronic unit injector remains deactivated. This process reduces white smoke.The following conditions must be met to activate the Cold Cylinder Cutout:
The Cold Cylinder Cutout parameter is programmed to "ENABLE".
The fuel rack is less than 13 mm (0.5 inch).
The jacket water coolant temperature is less than 63 °C (145 °F).The Cold Cylinder Cutout strategy is activated under either of the following conditions:
Ten seconds after the engine reaches the low idle rpm
Three seconds after ether injection is completedThe following conditions will deactivate the Cold Cylinder Cutout:
The Cold Cylinder Cutout parameter is programmed to "DISABLED".
The jacket water coolant temperature is more than 70 °C (158 °F).
A Cat ET is used for the cold cylinder cutout test.
The ether injection system is used.
The coolant temperature sensor has failed.
The engine is operating at a certain rpm when the Cold Cylinder Cutout is activated. If the engine rpm then varies by more than 50 rpm, the feature is deactivated for 3 seconds. A new engine speed is established when the feature is reactivated.
The engine is at low idle rpm for 10 seconds. If the engine speed is reduced by more than 50 rpm, the Cold Cylinder Cutout is deactivated for 30 seconds.
If the fuel rack is greater than 13 mm (0.5 inch), the Cold Cylinder Cutout is deactivated for one second.Droop
This feature enables an engine to share a load with other engines. If an engine is operating at high idle rpm and a load is applied, the engine rpm is reduced. The engine rpm is reduced as the load increases. This reduction in rpm is the droop. The droop can be programmed from zero to 10 percent. If the percent of droop is equal for two identical engines in parallel operation, the engines share the load equally.Ether Control (If Equipped)
The ECM automatically injects ether into the air inlet manifold when the following conditions are met:
The engine rpm is between 75 and 400 rpm.
The jacket water coolant temperature is below 30 °C (86 °F).The duration of ether injection varies linearly with the jacket water coolant temperature. The duration of ether injection varies within the following ran
Parts foam EVINRUDE:
0349434
0349434 *FOAM BARRIER, Front - Port
E200FCXSNF, E200FCXSOE, E200FCXSRB, E200FCXSTM, E200FHLSOR, E200FHLSRC, E200FPLSNF, E200FPLSOE, E200FPLSRB, E200FPLSTM, E225FCXSNF, E225FCXSOE, E225FCXSRB, E225FCXSTM, E225FHLSOB, E225FHLSRM, E225FHLSTA, E225FPLSOE, E225FPLSRB, E250FCXSNF, E250FCXSOB
0349438
0349438 *FOAM BARRIER, Center - Port
E200FCXSNF, E200FCXSOE, E200FCXSRB, E200FCXSTM, E200FHLSOR, E200FHLSRC, E200FPLSNF, E200FPLSOE, E200FPLSRB, E200FPLSTM, E225FCXSNF, E225FCXSOE, E225FCXSRB, E225FCXSTM, E225FHLSOB, E225FHLSRM, E225FHLSTA, E225FPLSOE, E225FPLSRB, E250FCXSNF, E250FCXSOB
0349435
0349435 *FOAM BARRIER. Front - Stbd
E200FCXSNF, E200FCXSOE, E200FCXSRB, E200FCXSTM, E200FHLSOR, E200FHLSRC, E200FPLSNF, E200FPLSOE, E200FPLSRB, E200FPLSTM, E225FCXSNF, E225FCXSOE, E225FCXSRB, E225FCXSTM, E225FHLSOB, E225FHLSRM, E225FHLSTA, E225FPLSOE, E225FPLSRB, E250FCXSNF, E250FCXSOB
0349439
0349439 *FOAM BARRIER, Center - Stbd
E200FCXSNF, E200FCXSOE, E200FCXSRB, E200FCXSTM, E200FHLSOR, E200FHLSRC, E200FPLSNF, E200FPLSOE, E200FPLSRB, E200FPLSTM, E225FCXSNF, E225FCXSOE, E225FCXSRB, E225FCXSTM, E225FHLSOB, E225FHLSRM, E225FHLSTA, E225FPLSOE, E225FPLSRB, E250FCXSNF, E250FCXSOB
0349650
0349650 *FOAM BARRIER, Rear - Stbd
E200FCXSNF, E200FCXSOE, E200FCXSRB, E200FCXSTM, E200FHLSOR, E200FHLSRC, E200FPLSNF, E200FPLSOE, E200FPLSRB, E200FPLSTM, E225FCXSNF, E225FCXSOE, E225FCXSRB, E225FCXSTM, E225FHLSOB, E225FHLSRM, E225FHLSTA, E225FPLSOE, E225FPLSRB, E250FCXSNF, E250FCXSOB