0335042 EVINRUDE FRAME


0335042 FRAME EVINRUDE BE40EEDS, BE50BEEDS, E40ECEC, E40EEIA, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB, E48ESLEDC, E48ESLEDC, E48ESLEOS, E48ESLEOS, E48ESLETE, E48ESLETE, E50BECEC, E50BEEIA, E50BEENJ, E50BEEOD, E50BEERE, E50BEESR, E50BEETB, E50TELCEC, VE48ESLETE FRAME
0335042 FRAME EVINRUDE
Rating:
53

Buy FRAME 0335042 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 21
 

BRP EVINRUDE entire parts catalog list:

BE40EEDS, BE40ELEDS, BE40TLEDS, E40ELEDS, E40REDS, E40RLEDS, E40TEEDS, E40TELEDS, E40TLEDS, E40TTLEDS, HE40REDS, HE40RLEDS 1996
BE50BEEDS, BE50BELEDS, BE50TLEDS, E50JEDS, E50TLEDS, SE50TLEDS 1996
E40ECEC, E40ELCEC, E40RCEC, E40RLCEC, E40TECEC, E40TELCEC, E40TLCEC, E40TTLCEC, TE40ELCEC 1989
E40EEIA, E40ELEIA, E40REIA, E40RLEIA, E40TEEIA, E40TELEIA, E40TLEIA, E40TTLEIA, TE40ELEIA, VE40EEIA, VE40ELEIA, VE40TELEIA, VE40TLEIA 1991
E40EENJ, E40EENM, E40ELENJ, E40ELENM, E40RENM, E40RLENM, E40TEENJ, E40TEENM, E40TELENJ, E40TELENM, E40TLENJ, E40TLENM, E40TTLENM, TE40ELENJ, TE40ELENM, VE40EENJ, VE40EENM, VE40ELENJ, VE40ELENM, VE40TELENJ, VE40TELENM, VE40TLENJ, VE40TLENM 1992
E40EEOD, E40ELEOD, E40REOD, E40RLEOD, E40TEEOD, E40TELEOD, E40TLEOD, E40TTLEOD 1995
E40EERE, E40ELERE, E40RERE, E40RLERE, E40TEERE, E40TELERE, E40TLERE, E40TTLERE 1994
E40EESR, E40ELESR, E40RESR, E40RLESR, E40TEESR, E40TELESR, E40TLESR, E40TTLESR, TE40ELESR, TE40TELESF, TE40TELESR, VE40EESR, VE40ELESR, VE40TELESR, VE40TLESR 1990
E40EETB, E40ELETB, E40RETB, E40RLETB, E40TEETB, E40TELETB, E40TLETB, E40TLETF, E40TTLETB, E40TTLETF, TE40ELETB, VE40EETB, VE40ELETB, VE40TELETB, VE40TLETB, VE40TLETF 1993
E48ESLEDC 1996
E48ESLEDC 1996
E48ESLEOS 1995
E48ESLEOS 1995
E48ESLETE, TE48ESLETE 1993
E48ESLETE, TE48ESLETE 1993
E50BECEC, E50BELCEC, E50TLCEC, TE50TLCEC, TE50TLESF 1989
E50BEEIA, E50BELEIA, E50JEIA, E50TELEIA, E50TLEIA, VE50BEEIA, VE50BELEIA, VE50TLEIA 1991
E50BEENJ, E50BEENM, E50BELENJ, E50BELENM, E50JENJ, E50JENM, E50TELENM, E50TLENJ, E50TLENM, VE50BEENJ, VE50BEENM, VE50BELENJ, VE50BELENM, VE50TELENM, VE50TLENJ, VE50TLENM 1992
E50BEEOD, E50BELEOD, E50JEOD, E50TELEOD, E50TLEOD 1995
E50BEERE, E50BELERE, E50JERE, E50TELERE, E50TLERE 1994
E50BEESR, E50BELESR, E50TELESR, E50TLESR, TE50TLESF, TE50TLESR, VE50BEESR, VE50BELESR, VE50TLESR 1990
E50BEETB, E50BELETB, E50JETB, E50TELETB, E50TLETB, E50TLETF, VE50BEETB, VE50BELETB, VE50TLETB, VE50TLETF 1993
E50TELCEC 1989
VE48ESLETE 1993

Information:


Illustration 1 g00597871
Schematic For Starting Motor Relay (SMR)The GSC uses the starting motor relay (SMR) to activate the following components: the starting motor magnetic switches ("SMMS1" and "SMMS2"), the "AUTO" position of the starting aid switch and the optional prelube pump. Also, the SMR deactivates the optional battery charge during engine cranking. The SMR is located within the relay module. "SMMS1" and "SMMS2" are located on the subpanel within the control panel.Note: Whenever the GSC activates the SMR, "K4" is shown on the lower display. "K4" is also shown on the lower display when the GSC attempts to activate the crank terminate relay. When the SMR is not activated, "K4" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the SMR.The following response is the system response to this fault while the SMR is activated:
If a CID 444 occurs, then the following events take place: the engine stops cranking, the prelube pump is disabled and the "AUTO" position of the starting aid switch is disabled. The battery charger will continue to function.The following response is the system response to this fault while the SMR is not activated:
If a CID 444 occurs, then the following events take place: the engine cannot crank, the engine cannot start, the prelube pump is disabled and the "AUTO" position of the starting aid switch is disabled. The battery charger will continue to function. If the engine is already running, then the engine continues to run.The GSC treats a CID 444 as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 444 FMI 12 is showing.
If the diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 444 FMI 12 is showing as a active fault or an inactive fault. Results:
No - A CID 444 FMI 12 has not occurred (NOT active and NOT inactive). STOP.
Yes - A CID 444 FMI 12is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK - Reassemble the relay module to the GSC. Proceed to 3.
NOT OK - Replace the connector clamp if it is missing. If the cable is damaged, replace the GSC. STOP.
Perform a functional check for the SMR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-18 of the relay module.
Remove the fuse "F4" from the relay module.
At the relay module, measure the resistance from RM-18 to RM-6. Resistance should be greater than 5000 ohms.
Prepare to measure the resistance from RM-18 to RM-6 of the relay module.
Turn the ECS to the START position. Quickly measure the resistance before the starting motor relay deactivates because of the crank time. Resistance should be less than 5 ohms.Expected Result: For 3.d, the resistance should be greater than 5000 ohms. For 3.f, the resistance should be less than 5 ohms.Results:
OK - It is likely that a temporary bad electrical connection existed and this troubleshooting procedure corrected it. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK - Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts frame EVINRUDE:

0211109
 
0211109 FRAME
E40ECEC, E40EEIA, E40EESR, E50BECEC, E50BEEIA, E50BEESR, E50TELCEC
0211081
 
0211081 FRAME
E40ECEC, E40EEIA, E40EESR, E48ESLCER, E48ESLCER, E48ESLEIM, E48ESLEIM, E48ESLESA, E48ESLESA, E50BECEC, E50BEEIA, E50BEESR, E50TELCEC, VE48ESLCER
0211082
 
0211082 FRAME
E40ECEC, E40EEIA, E40EESR, E48ESLCER, E48ESLCER, E48ESLEIM, E48ESLEIM, E48ESLESA, E48ESLESA, E50BECEC, E50BEEIA, E50BEESR, E50TELCEC, VE48ESLCER
0335033
 
0335033 FRAME
BE40EEDS, BE50BEEDS, E40ECEC, E40EEIA, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB, E48ESLEDC, E48ESLEDC, E48ESLEOS, E48ESLEOS, E48ESLETE, E48ESLETE, E50BECEC, E50BEEIA, E50BEENJ, E50BEEOD, E50BEERE, E50BEESR, E50BEETB, E50TELCEC, VE48ESLETE
0334236
 
0334236 FRAME
BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E40ECEC, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB, E48ESLCER, E48ESLCER, E48ESLEDC, E48ESLEDC, E48ESLENB, E48ESLENB, E48ESLEOS, E48ESLEOS, E48ESLERD, E48ESLERD, E48ESLESA, E48ESLESA, E
0334237
 
0334237 FRAME
BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E40ECEC, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB, E48ESLCER, E48ESLCER, E48ESLEDC, E48ESLEDC, E48ESLENB, E48ESLENB, E48ESLEOS, E48ESLEOS, E48ESLERD, E48ESLERD, E48ESLESA, E48ESLESA, E
0336076
 
0336076 FRAME, Front
E40EEIA, E48ESLEIM, E48ESLEIM, E50BEEIA
0336077
 
0336077 FRAME, Rear
E40EEIA, E48ESLEIM, E48ESLEIM, E50BEEIA
Back to top