0344526 EVINRUDE GASKET, Manifold to throttle assy.


0344526 GASKET, Manifold to throttle assy. EVINRUDE E100FPLSOC, E100FPLSRS, E115FPLEEC, E115FPLSDS, E115FPLSIF, E115FPLSNF, E115FPLSOD, E115FPLSRE, E115FPLSSH, E115FPLSTB, E115FPXSDS, E115FPXSOD, E115FPXSRE, E115FSLECS, E115FSLSDS, E75FPLSIF, E75FPLSNF, E75FPLSSH, E75FPLSTA, E90FPLEEC, E90FPLSIF, E90F GASKET
0344526 GASKET, Manifold to throttle assy. EVINRUDE
Rating:
83

Buy GASKET, Manifold to throttle assy. 0344526 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$21.01

10-11-2024
1.0[0.45] pounds
US: LEADERS RPM
Johnson Evinrude OMC New OEM Manifold To Throttle Assembly Gasket, 0344526
Johnson Evinrude OMC SKU: 0344526 || Sold Each || Please verify your own fitment
Number on catalog scheme: 24
 

BRP EVINRUDE entire parts catalog list:

E100FPLSOC, E100FSLSOC 2004,2005
E100FPLSRS, E100FSLSRS 2004
E115FPLEEC, E115FPLEEN, E115FPXEEC, E115FPXEEN, E115FSLEEC, E115FSLEEN 1999
E115FPLSDS 2006
E115FPLSIF, E115FPXSIF, E115FSLSIF, RE115FLSIF, RE115FSSIF, RE115FXSIF 2001
E115FPLSNF, E115FPXSNF 2002
E115FPLSOD, E115FSLSOD 2004,2005
E115FPLSRE, E115FSLSRE 2004
E115FPLSSH, E115FPLSSR, E115FPXSSH, E115FPXSSR, E115FSLSSH, E115FSLSSR, RE115FLSSSH, RE115FLSSSR, RE115FPLSSH, RE115FPLSSR, RE115FSSSH, RE115FSSSR, RE115FXSSH, RE115FXSSR 2000
E115FPLSTB, E115FPXSTB, E115FSLSTB 2003
E115FPXSDS 2006
E115FPXSOD 2004,2005
E115FPXSRE 2004
E115FSLECS, E115FSXECS, E115FTLECS 1998
E115FSLSDS 2006
E75FPLSIF, E75FVLSIF, RE75FPLSIF 2001
E75FPLSNF 2002
E75FPLSSH, RE75FPLSSH 2000
E75FPLSTA 2003
E90FPLEEC, E90FPLEEN 1999
E90FPLSIF, E90FVLSIF, RE90FPLSIF 2001
E90FPLSNF 2002
E90FPLSSH, E90FPLSSR, RE90FPLSSH, RE90FPLSSR 2000
E90FPLSTB, E90FSLSTB 2003
E90FSLECS, E90FTLECS 1998

Information:


Illustration 1 g03274357
Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Determine the Code
A. Establish communication between Cat® ET and the Electronic Control Module (ECM). Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the Aftertreatment ECM before performing any troubleshooting or clearing any diagnostic trouble codes.
C. Determine the diagnostic trouble code that is active.
   
Diagnostic Trouble Code    
Result: A 3965-5 or 5966-5 code is active.
Proceed to Test Step 2.
Result: A 3965-6 or 5966-6 code is active.
Proceed to Test Step 3.
Result: A 3966-6 or 6309-6 code is active.
Proceed to Test Step 4.
   
2. Check the Wiring for an Open Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be off for two minutes to allow the DEF pump to purge, to reset the code, and to reset the DCU.
B. Disconnect the 12 pin PETU harness connector. Verify that the harness connector is free of debris, corrosion and securely connected.
C. Install a jumper wire between pin 5 on the 12 pin connector on the A5:E2 aftertreatment controller side and a known good ground.
D. Turn the keyswitch to the ON position.
E. Check for an active code.
   
Diagnostic Trouble Code    
Result: A 3965-5 or 5966-5 and a 1235-9 or a 5856-9 code are both active at the same time.
An open circuit has been detected between the 12 pin PETU harness connector and the DCU harness 53 pin connector.
Repair: Replace the PETU wiring harness.
Verify that the problem is resolved. Return the unit to service.
Result: A 1235-9 or 5856-9 code is active.
An open circuit has been detected between the A5:E2 Aftertreatment Controller and the 12 pin PETU harness connector.
Repair: Repair or replace the wiring harness.
Verify that the problem is resolved. Return the unit to service.
   
3. Check the DCU Wiring for a Short Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be off for two minutes to allow the DEF pump to purge, to reset the code, and to reset the DCU.
B. Disconnect the 12 pin PETU harness connector. Verify that the harness connector is free of debris, corrosion and securely connected.
C. Turn the keyswitch to the ON position.
D. Check for an active code.
   
Diagnostic Trouble Code    
Result: A 3965-6 or 5966-6 and a 1235-9 or 5856-9 code are both active at the same time.
A short circuit has been detected between the A5:E2 Aftertreatment Controller and the 12 pin PETU harness connector.
Repair: Repair or replace the wiring harness.
Verify that the problem is resolved. Return the unit to service.
Result: A 1235-9 or 5856-9 code is active.
A short circuit has been detected between the 12 pin PETU harness connector and the DCU harness 53 pin connector.
Repair: Repair or replace the PETU wiring harness.
Verify that the problem is resolved. Return the unit to service.
   
4. Check the DCU Keyswitch Wiring for a Short Circuit to Ground
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be off for two minutes to allow the DEF pump to purge, to reset the code, and to reset the DCU.
B. Disconnect the 12 pin PETU harness connector. Verify that the harness connector is free of debris, and corrosion.
C. Disconnect the J1 connector on the A5:E2 aftertreatment controller. Measure the resistance between pin 29 and a known good ground.
   
Short Circuit    
Result: There was less than 100k ohms of resistance between pin 29 and ground.
A short circuit has been detected between pin 29 and ground.
Repair: Repair or replace the wiring harness.
Verify that the problem is resolved. Return the unit to service.
Result: There was more than 100k ohms of resistance between pin 29 and ground.
Proceed to Test Step 5.
   
5. Check the DCU Keyswitch Wiring for a Pin to Pin Short Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be off for two minutes to allow the DEF pump to purge, to reset the code, and to reset the DCU.
B. Disconnect the 12 pin PETU harness connector. Verify that the harness connector is free of debris, and corrosion.
C. Disconnect the J1 connector on the A5:E2 aftertreatment controller. Measure the resistance between pin 29 and all other pins in the 70 pin connector.
Note: There should be continuity between pins 10 and 29 only.
   
Short Circuit    
Result: There was less than 100k ohms of resistance between pin 29 and any other pin in the J1 connector except pin 10.
A short circuit has been detected.
Repair: Repair or replace the wiring harness.
Verify that the problem is resolved. Return the unit to service.
Result: There was more than 100k ohms of resistance between pin 29 and all other pins in the J1 connector except pin 10.
Inspect the wiring for an intermittent short.
Repair: Repair or replace the wiring harness.
Verify that the problem is resolved. Return the unit to service.
   


Parts gasket EVINRUDE:

0324670
 
0324670 GASKET, Solenoid cover
100990S, 150940C, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE225CXECS, BE225CXEDE, BE225CXEUD, BE25
0123231
GASKET,Cap
0123231 GASKET,Cap
BE10EEDD, BE10FAEDC, BE10FDLEDR, BE15EEDS, BE15FAEDR, BE20SEEDA, BE20SREDA, BE25BAEDR, BE25EEDM, BE30BAEDE, BE30EEDE, BE40EEDS, BE50BEEDS, BE50DTLEDC, BE5FRBEUS, BE60ELEDR, BE70ELEDA, BE8FRBEDC, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STL
0338484
GASKET, Imp. hsg. plate
0338484 GASKET, Imp. hsg. plate
BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE225CXECS, BE225CXEDE, BE225CXEUD, BE250CXECB, BE250CXEDA
0914634
 
0914634 GASKET, Connector
E115FPLEEC, E115FPLSIF, E115FPLSSH, E115FSLECS, E135FCXSDE, E135FCXSIF, E135FCXSSS, E135FPLSDE, E135FPXSDE, E135FSLSDE, E150FCXECR, E150FCXEEA, E150FCXSDR, E150FCXSIF, E150FCXSSM, E150FHLSDR, E150FPLSDR, E150FPXSDR, E150FSLSDR, E150ICXEUC, E175FCXECS
0344386
GASKET, Housing to powerhead
0344386 GASKET, Housing to powerhead
BE115GLECM, BE90SLECM, E100FPLSOC, E100FPLSRS, E100WPLEEC, E100WPLSIF, E100WPLSSR, E100WQLECS, E105WELEEN, E105WELSIF, E105WELSSC, E105WRLEES, E105WRLSIF, E105WRLSSC, E115FPLEEC, E115FPLSDS, E115FPLSIF, E115FPLSNF, E115FPLSOD, E115FPLSRE, E115FPLSSH,
0344733
 
0344733 GASKET
E115FPLEEC, E115FPLSIF, E115FPLSSH, E115FSLECS, E135FCXSIF, E135FCXSSS, E150FCXEEA, E150FCXSIF, E150FCXSSM, E175FCXEEC, E175FCXSIF, E175FCXSSR, E75FPLSIF, E75FPLSSH, E90FPLEEC, E90FPLSIF, E90FPLSSH, E90FSLECS
0345044
GASKET, Manifold to block - port
0345044 GASKET, Manifold to block - port
E100FPLSRS, E115FPLEEC, E115FPLSIF, E115FPLSNF, E115FPLSRE, E115FPLSSH, E115FPLSTB, E115FPXSRE, E115FSLECS, E75FPLSIF, E75FPLSNF, E75FPLSSH, E75FPLSTA, E90FPLEEC, E90FPLSIF, E90FPLSNF, E90FPLSSH, E90FPLSTB, E90FSLECS
0345045
GASKET, Manifold to block - stbd.
0345045 GASKET, Manifold to block - stbd.
E100FPLSRS, E115FPLEEC, E115FPLSIF, E115FPLSNF, E115FPLSRE, E115FPLSSH, E115FPLSTB, E115FPXSRE, E115FSLECS, E75FPLSIF, E75FPLSNF, E75FPLSSH, E75FPLSTA, E90FPLEEC, E90FPLSIF, E90FPLSNF, E90FPLSSH, E90FPLSTB, E90FSLECS
Back to top