0389837 GEARCASE,Cover & seal EVINRUDE
E4RDHCCS, E4RDHCDE, E4RDHCEC, E4RDHCUD, E4RDHESR, E5RCIC, E5RCSS, E5RHCNR, E5RHCTA, E6RCCS, E6RCDE, E6RCEC, E6RCOB, E6RCRM, E6RCUD, E6RESR, E8RCCS, E8RCDE, E8RCEC, E8RCIC, E8RCNR, E8RCOB, E8RCRM, E8RCSS, E8RCTA, E8RCUD, E8RESR
GEARCASE
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
- GEARCASE » 0389837
E4RDHCEC, E4RDHLCEC 1989
E4RDHCUD, E4RDHLCUD 1987
E4RDHESR, E4RDHLESR 1990
E5RCIC, E5RHCIC, E5RHLCIC, E5RLCIC 1981
E5RCSS, E5RHCSS, E5RHLCSS, E5RLCSS 1980
E5RHCNR, E5RHLCNR 1982
E5RHCTA, E5RHLCTA 1983
E6RCCS, E6RLCCS, E6SLCCS 1988
E6RCDE, E6RLCDE, E6SLCDE 1986
E6RCEC, E6RLCEC, E6SLCEC 1989
E6RCOB, E6RLCOB, E6SLCOB 1985
E6RCRM, E6RLCRM, E6SLCRM 1984
E6RCUD, E6RLCUD, E6SLCUD 1987
E6RESR, E6RLESR, E6SLESR 1990
E8RCCS, E8RLCCS, E8SRLCCS 1988
E8RCDE, E8RLCDE, E8SRLCDE 1986
E8RCEC, E8RLCEC, E8SRLCEC, TE8RCEC, TE8RLCEC 1989
E8RCIC, E8RLCIC 1981
E8RCNR, E8RLCNR, E8SRLCNR 1982
E8RCOB, E8RLCOB, E8SRLCOB 1985
E8RCRM, E8RLCRM, E8SRLCRM 1984
E8RCSS, E8RLCSS 1980
E8RCTA, E8RLCTA, E8SRLCTA 1983
E8RCUD, E8RLCUD, E8SRLCUD 1987
E8RESR, E8RLESR, E8SRLESR, TE8RLESCF 1990
Information:
Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
Note: Inspect the water pump and the water temperature regulator after the cooling system has been drained. This is a good opportunity to replace the water pump, the water temperature regulator and the hoses, if necessary. Drain
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap.
Illustration 1 g01003928
Open the cooling system drain valve (if equipped). If the cooling system is not equipped with a drain valve, remove the drain plug (1). Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Dealer Service Tools Group:Outside Illinois 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
Flush
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plug (1). Install the drain plug. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plug (1). Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plug. Install the drain plug. Refer to Torque Specifications, SENR3130 for more information on the correct torques. Cooling Systems with Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be some active flow through the cooling system components.
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plug (1). Install the drain plug. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 90 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plug (1). Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plug. Install the drain plug. Refer to Torque Specifications, SENR3130 for more information on the correct torques. Fill
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with coolant or antifreeze. Refer to this Operation and Maintenance Manual, "Refill Capacities and Recommendations" topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap.
Start and run the engine at low idle. Increase the engine rpm to 1500 rpm. Run the engine at high idle for one minute in order to purge the air from the cavities of the engine block. Stop the engine.
Check the coolant level. Maintain the coolant level within 13 mm