0314832 GROMMET, Water tube EVINRUDE
100193A, 100293R, 115083D, 115393M, 115493B, 115593, 115693D, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 85093B, 85193A, 85293R, 85393M, 85493B, 85593E, 85693D, 85993E
GROMMET
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
- GEARCASE » 0314832
115083D 1970
115393M 1973
115493B 1974
115593 1975
115693D, 115693G, 115699D, 115699G 1976
115983E, 115983S 1969
125183C 1971
125283R 1972
135383M 1973
135443B, 135483B, 135489B 1974
135543E, 135583E, 135589E 1975
135643D, 135643G, 135683D, 135683G 1976
85093B, 85093D 1970
85193A, 85193H 1971
85293R 1972
85393M 1973
85493B 1974
85593E 1975
85693D, 85693G, 85699G 1976
85993E, 85993M, 85993S 1969
Information:
(1) Tighten switch assembly to ... 30 3 N m (22 2 lb ft)(2) Torque for terminal screws ... 1.7 0.3 N m (15 3 lb in)Contact position ... normally open below deacuation pressureActuation pressure ... 24.0 3.5 kPa (3.5 .5 psi)Deactuation pressure ... 20 kPa (3 psi) minimumTemperature range (operating) ... -40 to 121°C (-40.0 to 250°F)6T6652, 9X4276
6T6652
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 103 kPa (15 psi).Terminal No. 3 is normally closed below 103 kPa (15 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 158 28 kPa (23 4 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 124 21 kPa (18 3 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)9X4276
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 48 kPa (7 psi).Terminal No. 3 is normally closed below 48 kPa (7 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 93.0 20.8 kPa (13.5 3.0 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 68.9 20.8 kPa (10.0 3.0 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)7N5946
Terminal No. 1 is normally open below actuation pressure.Terminal No. 2 is normally closed below actuation pressure.Terminal No. 3 is common.With pressure increase, terminal No. 2 closes and terminal No. 1 opens at ... 145 kpa (21 psi)With pressure decrease, terminal No. 2 opens and terminal No. 1 closes at ... 76 21 kPa (11 3 psi)Temperature range (operating) ... -54 to 104°C (-65 to 220°F)Starter Magnetic (24V)
Current consumption (draw) at 25°C (77°F) ... 0.82 0.06A at 17V(1) Torque for large terminal nuts ... 3.6 0.4 N m (32 4 lb in)(2) Torque for small terminal nuts ... 1.70 0.25 N m (15 2 lb in)Temperature
3N7442
Switch position at 0°C (32°F) ... closedSwitch must open at ... 27 3°C (81 37°F)Switch must close at ... 21 3°C (70 37°F)2W8915, 7C9365
7C9365
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 100 C° (212.0 F°), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8915
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 91°C (196°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916, 5N8857
5N8857
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal A closes and terminal C opens.With a temperature decrease of 91°C (196°F), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 92 C° 1.5°C (198 35°F), terminal A closes and terminal C opens.With a temperature decrease of 85°C (185°F), terminal No. A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)108-3190
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal A closes and terminal C opens.With a temperature decrease of 100 C° (212.0 F°), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)
6T6652
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 103 kPa (15 psi).Terminal No. 3 is normally closed below 103 kPa (15 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 158 28 kPa (23 4 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 124 21 kPa (18 3 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)9X4276
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 48 kPa (7 psi).Terminal No. 3 is normally closed below 48 kPa (7 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 93.0 20.8 kPa (13.5 3.0 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 68.9 20.8 kPa (10.0 3.0 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)7N5946
Terminal No. 1 is normally open below actuation pressure.Terminal No. 2 is normally closed below actuation pressure.Terminal No. 3 is common.With pressure increase, terminal No. 2 closes and terminal No. 1 opens at ... 145 kpa (21 psi)With pressure decrease, terminal No. 2 opens and terminal No. 1 closes at ... 76 21 kPa (11 3 psi)Temperature range (operating) ... -54 to 104°C (-65 to 220°F)Starter Magnetic (24V)
Current consumption (draw) at 25°C (77°F) ... 0.82 0.06A at 17V(1) Torque for large terminal nuts ... 3.6 0.4 N m (32 4 lb in)(2) Torque for small terminal nuts ... 1.70 0.25 N m (15 2 lb in)Temperature
3N7442
Switch position at 0°C (32°F) ... closedSwitch must open at ... 27 3°C (81 37°F)Switch must close at ... 21 3°C (70 37°F)2W8915, 7C9365
7C9365
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 100 C° (212.0 F°), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8915
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 91°C (196°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916, 5N8857
5N8857
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal A closes and terminal C opens.With a temperature decrease of 91°C (196°F), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 92 C° 1.5°C (198 35°F), terminal A closes and terminal C opens.With a temperature decrease of 85°C (185°F), terminal No. A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)108-3190
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal A closes and terminal C opens.With a temperature decrease of 100 C° (212.0 F°), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)
Parts grommet EVINRUDE:
0551426
0551426 GROMMET,Rubber
100193A, 100293R, 100882B, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 55872A, 55972A, 60072B, 60172C, 65832B, 85093B, 85193A, 85293R, 85393M, 85493B, 85593E, 85693D, 85
0305760
0305760 GROMMET,Extension tube
100193A, 100293R, 100882B, 115083D, 115983E, 125183C, 125283R, 55872A, 65832B, 85093B, 85193A, 85293R, 85852A, 85892A, 85993E
0308523
0308523 GROMMET,Shift cable
100882B, 115983E, 40072A, 40872A, 40972R, 55872A, 55972A, 85892A, 85993E
0305145
0305145 GROMMET
100193A, 100293R, 100990S, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 55872A, 55972A, 60072B, 60172C, 65272S, 65372R, 65832
0206420
0206420 GROMMET, Instrument cable
100193A, 100293R, 115083D, 125183C, 125283R, 50172S, 50202C, 60072B, 60172C, 65272S, 85093B, 85193A, 85293R
0316354
0316354 GROMMET, Motor cover
100293R, 100990S, 10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 15404G, 15504C, 15604A, 175740S, 200640S, 25904R, 50172S, 5
0318369
0317844
0317844 GROMMET, Water tube imp.
115393M, 115493B, 115593, 115693D, 115793S, 135383M, 135443B, 135543E, 135643D, 85393M, 85493B, 85593E, 85693D