Illustration 1 g01626598
Illustration 2 g01635537
(1) + Battery (21) - BatteryUse this procedure to troubleshoot the electrical system if a problem is suspected with the power to the engine's Electronic Control Module (ECM) or if the diagnostic code in the Table is active or easily repeated.
Table 1
Diagnostic Code    
Code and Description     Flash Code     Default Conditions which Generate this Code     System Response    
168-02 ECM Battery Power Intermittent     51     Battery voltage at the ECM is less than 7 VDC.     The code is logged.    Test Step 1. Inspect the Electrical Connectors and the Wiring Harness
Remove electrical power from the ECM.
Thoroughly inspect the ECM connector J14/P14. Also, inspect connector J17/P17. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit for the Power Supply.
Check the allen head screw on the ECM connector for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The connectors and wiring are OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or the wiring.Repair: Repair the wiring and connectors or replace the wiring or the connectors. Ensure that all of the seals are properly connected. Verify that the repair eliminates the problem.Verify that the repair eliminates the problem.STOPTest Step 2. Check Battery Voltage at the Battery
Turn the engine control switch to the OFF position.
Turn the circuit breaker for the battery to the OFF position.
Measure no-load battery voltage at the battery terminals. Refer to Testing and Adjusting, "Test Tools for the Electrical System" for the proper procedures to check the batteries.
Load test the battery. Use the 4C-4911 Battery Load Tester .Expected Result:The no-load voltage at the batteries is at least 23.5 VDC and the batteries pass the load test.Results:
OK - The no-load voltage at the batteries is at least 23.5 VDC and the batteries pass the load test. Proceed to Test Step 3.
Not OK - The no-load voltage at the batteries is less than 23.5 VDC, and/or the batteries fail the load test.Repair: The batteries or the alternator are causing the problem. Recharge the batteries or replace the batteries. Refer to Systems Operation/Testing and Adjusting.STOPTest Step 3. Check the Voltage to the ECM
Disconnect the ECM connector J14/P14.
Turn the circuit breaker for the battery to the ON position.
Turn the engine control switch to the ON position.
Measure the voltage between the following pins.
P14-1 and P14-21
P17-19 and P17-13Expected Result:The voltage measures 24 3 VDC.Results:
OK - The ECM is receiving the correct battery voltage.Repair: The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The voltage is incorrect at the connection to the ECM. The wiring or components between the battery and the ECM are preventing the voltage from reaching the ECM. Proceed to Test Step 4.Test Step 4. Check Voltage at the Circuit Breaker
Turn the circuit breaker for the battery to the ON position.
Turn the engine control switch to the ON position.
Measure voltage from both terminals of the breaker to engine ground.Expected Result:The voltage measures 24 3 VDC on both terminals.Results:
OK - The voltage measures 24 3 VDC on both terminals. If the voltage is only present on one of the terminals, replace the fuse.Repair: The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The voltage does not measure 24 3 VDC on both terminals.Repair: The fuse or the breaker is in need of repair or replacement.STOP


Parts grommet EVINRUDE:

0204911
GROMMET, Starter handle support
0204911 GROMMET, Starter handle support
18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 25904R, 35602G, 40202E, 40304D, 40404S, 40504C, 40604A, B25JREUR, BE20SRECB, BE20SREDA, BE20SREUM, BE25BAECM, BE25BAEDR, B
0304026
GROMMET, Water tube
0304026 GROMMET, Water tube
33002M, 33802M, 33902A, 40002A, 40052A, 40072A, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 40802A, 40852A, 40872A, 40902R, 40952R, 40972R, E40RSLR, E40RWCDB, E40RWCOM, E40RWCRA
0304019
 
0304019 GROMMET, Control shaft
18002C, 18102S, 18202R, 18304A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 25904R, 33002M, 33802M, 33902A, 35602G, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, B25JREUR, BE20SEECB, BE20SEEDA, BE20SEEUM,
0316354
GROMMET, Motor cover
0316354 GROMMET, Motor cover
100293R, 100990S, 10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 15404G, 15504C, 15604A, 175740S, 200640S, 25904R, 50172S, 5
0318262
 
0318262 GROMMET
40304D, 40404S, 40504C, 40604A, E40RSLR, E40RWCDB, E40RWCOM, E40RWCRA
Back to top