0351232 GROMMET, Water exit EVINRUDE
E25DELSES, E25DPLSES, E25DRLSES, E25DTELSES, E25DTLSES, E30DELSES, E30DPLSES, E30DRLSES, E30DTELSES, E30DTLSES, E40DELSDA, E40DELSOR, E40DELSRC, E40DPLSCB, E40DPLSDA, E40DPLSOR, E40DPLSRC, E40DPLSUM, E40DRLSCB, E40DRLSDA, E40DRLSOR, E40DRLSRC, E40DRL
GROMMET
Price: query
Rating:
Compatible models:
E25DELSES
E25DPLSES
E25DRLSES
E25DTELSES
E25DTLSES
E30DELSES
E30DPLSES
E30DRLSES
E30DTELSES
E30DTLSES
E40DELSDA
E40DELSOR
E40DELSRC
E40DPLSCB
E40DPLSDA
E40DPLSOR
E40DPLSRC
E40DPLSUM
E40DRLSCB
E40DRLSDA
E40DRLSOR
E40DRLSRC
E40DRLSUM
E40DTLSCS
E50DPLSCB
E50DPLSDA
E50DPLSOR
E50DPLSRC
E50DPLSUM
E50DTLSCS
E55MJRLSCC
E55MRLSCC
E60DPLSCB
E60DPLSDA
E60DPLSUM
E60DTLSCS
E60WDRLSOS
E65WDRLSCS
E75DPLSCB
E75DPLSDA
E75DPLSOR
E75DPLSRC
E75DPLSUM
E75DSLSCS
E90DPLSCB
E90DPLSDA
E90DPLSOR
E90DPLSRC
E90DPLSUM
E90DPXSCB
E90DPXSDA
E90DPXSOR
E90DPXSRC
E90DPXSUM
E90DSLSCM
E90DSLSDR
E90DSLSOC
E90DSLSRC
E90DSLSUM
E90WDELSCS
E90WDEXSCS
E90WDPLSOS
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- COOLING HOSES » 0351232
E25DRLSES, E25DRSES 2009
E25DTELSES, E25DTESES 2009
E25DTLSES 2009
E30DELSES 2009
E30DPLSES 2009
E30DRLSES, E30DRSES 2009
E30DTELSES 2009
E30DTLSES 2009
E40DELSDA 2006
E40DELSOR 2004,2005
E40DELSRC 2004
E40DPLSCB, E40DSLSCS 2008
E40DPLSDA 2006
E40DPLSOR 2004,2005
E40DPLSRC 2004
E40DPLSUM 2007
E40DRLSCB 2008
E40DRLSDA 2006
E40DRLSOR 2004,2005
E40DRLSRC 2004
E40DRLSUM 2007
E40DTLSCS 2008
E50DPLSCB, E50DSLSCS 2008
E50DPLSDA 2006
E50DPLSOR 2004,2005
E50DPLSRC 2004
E50DPLSUM 2007
E50DTLSCS 2008
E55MJRLSCC 2008
E55MRLSCC 2008
E60DPLSCB, E60DSLSCS 2008
E60DPLSDA 2006
E60DPLSUM 2007
E60DTLSCS 2008
E60WDRLSOS, E60WDRYSOS 2004,2005
E65WDRLSCS, E65WDRYSCS 2008
E75DPLSCB 2008
E75DPLSDA 2006
E75DPLSOR 2004,2005
E75DPLSRC 2004
E75DPLSUM 2007
E75DSLSCS 2008
E90DPLSCB 2008
E90DPLSDA 2006
E90DPLSOR 2004,2005
E90DPLSRC 2004
E90DPLSUM 2007
E90DPXSCB 2008
E90DPXSDA 2006
E90DPXSOR 2004,2005
E90DPXSRC 2004
E90DPXSUM 2007
E90DSLSCM 2008
E90DSLSDR 2006
E90DSLSOC 2004,2005
E90DSLSRC 2004
E90DSLSUM 2007
E90WDELSCS 2008
E90WDEXSCS 2008
E90WDPLSOS 2004,2005
Information:
Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
401-5 Ignition Transformer Secondary #1 : Current Below Normal
402-5 Ignition Transformer Secondary #2 : Current Below Normal
403-5 Ignition Transformer Secondary #3 : Current Below Normal
404-5 Ignition Transformer Secondary #4 : Current Below Normal
405-5 Ignition Transformer Secondary #5 : Current Below Normal
406-5 Ignition Transformer Secondary #6 : Current Below Normal
407-5 Ignition Transformer Secondary #7 : Current Below Normal
408-5 Ignition Transformer Secondary #8 : Current Below Normal
409-5 Ignition Transformer Secondary #9 : Current Below Normal
410-5 Ignition Transformer Secondary #10 : Current Below Normal
411-5 Ignition Transformer Secondary #11 : Current Below Normal
412-5 Ignition Transformer Secondary #12 : Current Below Normal
413-5 Ignition Transformer Secondary #13 : Current Below Normal
414-5 Ignition Transformer Secondary #14 : Current Below Normal
415-5 Ignition Transformer Secondary #15 : Current Below Normal
416-5 Ignition Transformer Secondary #16 : Current Below Normal While the engine is started, the Electronic Control Module (ECM) detects a low current flow in the secondary circuit for the ignition transformer. The code is logged.
The alarm output is activated.
Table 2
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
401-6 Ignition Transformer Secondary #1 : Current Above Normal
402-6 Ignition Transformer Secondary #2 : Current Above Normal
403-6 Ignition Transformer Secondary #3 : Current Above Normal
404-6 Ignition Transformer Secondary #4 : Current Above Normal
405-6 Ignition Transformer Secondary #5 : Current Above Normal
406-6 Ignition Transformer Secondary #6 : Current Above Normal
407-6 Ignition Transformer Secondary #7 : Current Above Normal
408-6 Ignition Transformer Secondary #8 : Current Above Normal
409-6 Ignition Transformer Secondary #9 : Current Above Normal
410-6 Ignition Transformer Secondary #10 : Current Above Normal
411-6 Ignition Transformer Secondary #11 : Current Above Normal
412-6 Ignition Transformer Secondary #12 : Current Above Normal
413-6 Ignition Transformer Secondary #13 : Current Above Normal
414-6 Ignition Transformer Secondary #14 : Current Above Normal
415-6 Ignition Transformer Secondary #15 : Current Above Normal
416-6 Ignition Transformer Secondary #16 : Current Above Normal While the engine is started, the ECM detects an excessive current flow in the primary circuit for the ignition transformer. The code is logged.
The alarm output is activated. The ignition transformers initiate combustion by providing high voltage to the spark plugs. The output from the secondary circuit of the transformer provides voltage to the terminals of the spark plug. The transformers are located underneath the valve covers. Each transformer is grounded to a valve cover via a ground spring.The secondary circuit of the transformer provides an initial 8,000 to 37,000 V to the spark plug. This voltage ionizes the air that is in the spark plug gap and generates a spark in the air gap. This voltage is then reduced to about 1,000 V. The total duration of the spark is approximately 400 microseconds.The ECM can diagnose the primary circuit of the ignition transformers for open circuits and/or for short circuits. Secondary open circuits and short circuits will not directly shut down the engine. However, these conditions may lead to misfire which can cause lugging of the engine. Lugging of the engine can cause a shutdown.Note: Ignition transformers that are used with Electronic Ignition Systems (EIS) are not interchangeable with the transformers that are used with ADEM III systems. Be sure not to interchange these components on any engine.Caterpillar spark plugs are high voltage devices with internal resistors. The spark plugs operate at a voltage that is greater than 5,000 V.Most ignition systems are affected by resistance in the secondary circuit. If a measurement of the resistance is desired, a megohmmeter must be used. A low voltage multimeter will not provide a reliable reading of the resistance. Oxidation of the spark plugs internal components will affect the readings for those meters.Test Step 1. Use Caterpillar Electronic Technician (ET) to Check the Output of the Transformers
Set the engine control switch to the OFF/RESET position. Remove the electrical power from the engine.
Connect Cat ET to the service tool connector.
Restore the electrical power to the engine. Set the engine control switch to the STOP position.
Set up two status screens for Cat ET. Use the following labels for parameters on each Status screen:
Table 3
Parameters for the Status Screens on Cat ET
Screen 1 Screen 2
"Cylinder #1 Transformer Secondary Output Voltage Percentage" "Cylinder #2 Transformer Secondary Output Voltage Percentage"
"Cylinder #3 Transformer Secondary Output Voltage Percentage" "Cylinder #4 Transformer Secondary Output Voltage Percentage"
"Cylinder #5 Transformer Secondary Output Voltage Percentage" "Cylinder #6 Transformer Secondary Output Voltage Percentage"
"Cylinder #7 Transformer Secondary Output Voltage Percentage" "Cylinder #8 Transformer Secondary Output Voltage Percentage"
"Cylinder #9 Transformer Secondary Output Voltage Percentage" "Cylinder #10 Transformer Secondary Output Voltage Percentage"
"Cylinder #11 Transformer Secondary Output Voltage Percentage" "Cylinder #12 Transformer Secondary Output Voltage Percentage"
"Cylinder #13 Transformer Secondary Output Voltage Percentage" "Cylinder #14 Transformer Secondary Output Voltage Percentage"
"Cylinder #15 Transformer Secondary Output Voltage Percentage" "Cylinder #16 Transformer Secondary Output Voltage Percentage"
"Cylinder #17 Transformer Secondary Output Voltage Percentage" "Cylinder #18 Transformer Secondary Output Voltage Percentage"
"Cylinder #19 Transformer Secondary Output Voltage Percentage" "Cylinder #20 Transformer Secondary Output Voltage Percentage"
Start the engine. Allow the engine to warm up to normal operating temperature. Apply the normal load at rated speed.
Observe the value of the output for the secondary circuit of each transformer. Expected Result:The displayed value of the output for the secondary circuit of each transformer is between 1 and 90 percent.Results:
OK - The displayed value of the output for the secondary circuit of each transformer is between 1 and 90 percent.Repair: The ignition system components are operating properly. Investigate other possible root causes of the problem. Troubleshoot the symptom. Refer to Troubleshooting, "Symptom Troubleshooting".STOP
Not OK - At least one of the outputs displayed a value of 0 percent or a value that is greater than 90 percent. The ignition system components require maintenance. Proceed to Test Step 2.Test Step 2. Inspect the Condition of the Transformer
Ignition systems can cause electrical shocks. Avoid contacting the ignition system components and wiring.Do not attempt to remove the valve covers when the engine is operating. The transformers are grounded to the valve covers. Personal injury or death may result and the ignition system will be damaged if the valve covers are removed during
Parts grommet EVINRUDE:
0302497
0302497 GROMMET, Water tube
10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 15404G, 15504C, 15604A, 18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 25904R, 35602G, 6002B, 6102E, 6202D, 6302S, 6402C,
0305145
0305145 GROMMET
100193A, 100293R, 100990S, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 55872A, 55972A, 60072B, 60172C, 65272S, 65372R, 65832
0314008
0314008 GROMMET, Water tube
100990S, 115790S, 115890C, 150840S, 150940C, 175740S, 200640S, 55872A, 55972A, 60072B, 60172C, 65272S, 65372R, 70442M, 70572B, 70673D, 70773S, 70873C, 70973R, 75542B, 75642D, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE1
0320943
0320943 GROMMET,Impeller housing
100990S, 115790S, 115890C, 150840S, 150940C, 175740S, 200640S, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CX
0329518
0329518 GROMMET, Base to hose
BE115ELEDR, BE115ELEUA, BE115GLECM, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE90ELEDR, BE90ELEUA, BE90SLECM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, DE150CXAAA, DE150CXAAC, DE150CXINS, DE150PXAAA, DE150PXAAC, D
0332363
0332363 GROMMET, Tube to adapter
E35AELCDE, E35AELCUD, E40AELCCS, E40DELSOR, E40DELSRC, E40DPLSOR, E40DPLSRC, E40DRLSOR, E40DRLSRC, E40ECDE, E40ECUD, E40WREES, E40WRLSIR, E40WRLSSC, E45RCCUC, E45RCE, E45RCEIA, E45RCENM, E45RCEOD, E45RCERE, E45RCESR, E45RCETB, E45RCLEDS, E45RCLEUC, E
0333758
0333758 GROMMET
BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E40DELSDA, E40DELSOR, E40DELSRC, E40DPLAAA, E40DPLABA, E40DPLIIS, E40DPLINC, E40DPLISD, E40DPLISF, E40DPLSCB, E40DPLSDA, E40DPLSEE, E40DPLSOR, E40DPLSRC, E40DPLSUM, E40DRLAAA, E40DRLABA,
0350973
0350973 GROMMET, Cover
E40DELSDA, E40DELSOR, E40DELSRC, E40DPLAAA, E40DPLABA, E40DPLIIS, E40DPLINC, E40DPLISD, E40DPLISF, E40DPLSCB, E40DPLSDA, E40DPLSEE, E40DPLSOR, E40DPLSRC, E40DPLSUM, E40DRLAAA, E40DRLABA, E40DRLIIS, E40DRLINC, E40DRLISD, E40DRLISF, E40DRLSCB, E40DRLSD