0215868 EVINRUDE H.O. WAVE, Port


0215868 H.O. WAVE, Port EVINRUDE DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD H
0215868 H.O. WAVE, Port EVINRUDE
Rating:
78

Buy H.O. WAVE, Port 0215868 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 15
 

BRP EVINRUDE entire parts catalog list:

DE200HXAAA, DE200HXAAB 2012
DE200HXAAC 2012
DE200HXAAD 2012
DE200XCAAA, DE200XCAAB 2012
DE200XCAAC 2012
DE200XCAAD 2012
DE225CXAAA, DE225CXAAB 2012
DE225CXAAC 2012
DE225CXAAD 2012
DE225CXINS 2012
DE225PXAAA, DE225PXAAB 2012
DE225PXAAC 2012
DE225PXAAD 2012
DE225PXINS 2012
DE250CXAAA, DE250CXAAB, DE250CZAAA, DE250CZAAB 2012
DE250CXAAC, DE250CZAAC 2012
DE250CXAAD, DE250CZAAD 2012
DE250CXISF, DE250CXISS, DE250CZISF, DE250CZISS 2010
DE250PXAAA, DE250PXAAB, DE250PZAAA, DE250PZAAB 2012
DE250PXAAC, DE250PZAAC 2012
DE250PXAAD, DE250PZAAD 2012
DE250PXISF, DE250PXISS, DE250PZISF, DE250PZISS 2010
DE300CXAAA, DE300CXAAB, DE300CZAAA, DE300CZAAB 2012
DE300CXAAC, DE300CZAAC 2012
DE300CXAAD, DE300CZAAD 2012
DE300CXIIC 2011
DE300CXINR, DE300CZINR 2012
DE300CXISF, DE300CXISG, DE300CXISS, DE300CZISF, DE300CZISG, DE300CZISS 2010
DE300CZIIC 2011
DE300PXAAA, DE300PXAAB, DE300PZAAA, DE300PZAAB 2012
DE300PXAAC, DE300PZAAC 2012
DE300PXAAD, DE300PZAAD 2012
DE300PXIIC, DE300PZIIC 2011
DE300PXINR, DE300PZINR 2012
DE300PXISF, DE300PXISG, DE300PXISS, DE300PZISF, DE300PZISG, DE300PZISS 2010
E200DHXAAA, E200DHXAAB, E200HSLAAA, E200HSLAAB 2012
E200DHXAAC, E200HSLAAC 2012
E200DHXAAD, E200HSLAAD 2012
E200DHXSEA, E200HVLSEC 2009
E200HCXAAA, E200HCXAAB 2012
E200HCXAAC 2012
E200HCXAAD 2012
E200HCXSEA 2009
E200HSLSEA 2009
E225DCXAAA, E225DCXAAB 2012
E225DCXAAC 2012
E225DCXAAD 2012
E225DCXIID, E225DCZIID 2011
E225DCXINS, E225DCZINS 2012
E225DCXISE, E225DCXISF, E225DCZISE, E225DCZISF 2010
E225DCXSEB, E225DCZSEB 2009
E225DHXIND, E225DPXINS, E225DPZINS, E225HSLINM 2012
E225DPXAAA, E225DPXAAB, E225HSLAAA, E225HSLAAB 2012
E225DPXAAC, E225HSLAAC 2012
E225DPXAAD, E225HSLAAD 2012
E225DPXIID, E225DPZIID, E225HSLIIA 2011
E225DPXISE, E225DPXISF, E225DPZISE, E225DPZISF 2010
E225DPXSEB, E225DPZSEB 2009
E225HSLISF, E225HSLISR 2010
E225HSLSEC 2009
E250DCXAAA, E250DCXAAB, E250DCZAAA, E250DCZAAB 2012
E250DCXAAC, E250DCZAAC 2012
E250DCXAAD, E250DCZAAD 2012
E250DCXISE, E250DCXISF, E250DCZISE, E250DCZISF 2010
E250DCXSEB, E250DCZSEB 2009
E250DPXAAA, E250DPXAAB, E250DPZAAA, E250DPZAAB 2012
E250DPXAAC, E250DPZAAC 2012
E250DPXAAD, E250DPZAAD 2012
E250DPXISE, E250DPXISF, E250DPZISE, E250DPZISF 2010
E250DPXSEB, E250DPZSEB 2009
E250HSLAAA, E250HSLAAB 2012
E250HSLAAC 2012
E250HSLAAD 2012
E250HSLSES 2009
E300DCXAAA, E300DCXAAB, E300DCZAAA, E300DCZAAB 2012
E300DCXAAC, E300DCZAAC 2012
E300DCXAAD, E300DCZAAD 2012
E300DCXIIA, E300DCZIIA 2011
E300DCXISF, E300DCXISG, E300DCXISR, E300DCZISF, E300DCZISG, E300DCZISR 2010
E300DCXSEC, E300DCZSEC 2009
E300DCZINM 2012
E300DPXAAA, E300DPXAAB, E300DPZAAA, E300DPZAAB, E300DSLAAA, E300DSLAAB 2012
E300DPXAAC, E300DPZAAC, E300DSLAAC 2012
E300DPXAAD, E300DPZAAD, E300DSLAAD 2012
E300DPXIIA, E300DPZIIA, E300DSLIIR 2011
E300DPXINM, E300DPZINM, E300DSLINA 2012
E300DPXISF, E300DPXISG, E300DPXISR, E300DPZISF, E300DPZISG, E300DPZISR, E300DSLISC, E300DSLISF, E300DSLISG 2010
E300DPXSEC, E300DPZSEC, E300DSLSES 2009

Information:

Electric Starting
1. Move the governor control lever to approximate half engine speed position. 2. Use starting aids if required. See the topic, STARTING AIDS.3. Push the START button; or turn the HEATSTART switch to the START position, depending upon the control the engine has. Release the control as soon as the engine starts. For generator sets, place the AUTO-MAN switch in the MAN position to crank the engine. As soon as the engine starts, and the engine speed reaches 600 rpm and oil pressure is approximately 22 psi (1.5 kg/cm2), the starter motor will disconnect from the circuit. (The STOP position is used to stop the diesel engine.) If the engine fails to start in 10 seconds, move the governor control lever to the fuel off position, then continue to crank for 10 seconds. This will clear the cylinders of unburned fuel.If the engine fails to start after 30 seconds of cranking, allow the engine to cool for 2 minutes before repeating the starting procedure.
Prolonged cranking at low oil pressure can activate the mechanical safety shut-off. If the reset lever is in the shut-off position, reset the mechanical shut-off control.
NEVER use starting aids when the engine is warm and running.
If the engine is equipped with a Woodward PSG Governor, see the topic, WOODWARD GOVERNORS for the governor operation instructions.Air Starting
1. Open and close the bleed valve on the bottom of the air tank to drain condensation and oil carryover.2. Check the air supply pressure. The air start must have 100 PSI (7 kg/cm2) to operate properly.3. Keep oil level, in the oiler jar, at least half full. Add oil if necessary. See the LUBRICATION AND MAINTENANCE PROCEDURES, Filling Motor Oiler. 4. Push the air valve control in to crank the engine. As soon as the engine starts, release the valve. Starting Aids
Many variables can affect cold weather starting. Use the chart as a guide, but actual experience will determine when aids are necessary and how they should be used. Your engine may have one or more of the following starting aids:Glow Plugs (Precombustion Chamber Engines Only)
1. Push in and turn the HEAT-START switch to the HEAT position and hold for the approximate heating time shown in the STARTING AID CHART. 2. Turn the HEAT-START switch to the START position. 3. If necessary, when the engine starts turn the HEAT-START switch to the HEAT position. Hold the switch in this position until the engine is running smoothly.4. Release the switch.
NEVER use glow plugs when the engine is warm and running.
Starting Fluid
Starting fluid is volatile and must be stored away from heat and direct sunlight. If an aerosol container is used, follow the instructions on the container.
Spray starting fluid only while cranking the engine.
1. Heat the glow plugs (If equipped) for the approximate heating time shown in the STARTING AID CHART. 2. Turn the HEAT-START switch to START position. While cranking, spray starting fluid into the air inlet or air cleaner for approximately 1 second.
Wait at least 2 seconds before spraying starting fluid again.
3. If necessary, repeat the procedure.4. After the engine starts, it may be necessary to return the HEAT-START switch to the HEAT position until the engine runs smoothly.Jacket Water Heater (Attachment)
In very low temperatures, the lubricating oil must be warmed to allow starting. A jacket water heater can maintain the water temperature at approximately 90°F (32°C). The warm water will keep the oil in the upper part of the engine block warm enough to flow when starting.Dipstick Oil Heater
Contact your Caterpillar dealer before installing a dipstick crankcase oil heater.
Generator
Starting Single Unit Operation
1. Make all preliminary engine starting checks.2. Be sure the main or line circuit breaker is open.3. Start the engine and allow it to warm up.4. Close the main circuit breaker.5. Apply the load. Do not try to apply full load in one move, rather apply the load in increments to maintain system frequency at a constant level.Standby Generator Sets
Most standby units are automatic. They start, pickup the load, run and stop without an operator in attendance. Standby units can not change the governor control setting automatically. The throttle must be preset for the proper operation of that unit. Whenever the set is exercised or operated manually, be sure the throttle setting is correct for automatic operation. Check all switches to see they are properly set: Start Selector Switch in AUTOMATIC position and any Emergency Stop Switches in RUN position.Paralleling
Units may be paralleled at no load or paralleled with units under load. To parallel two or more units the following conditions must be met:1. Same phase rotation.2. Same voltage level.3. Same volt


Parts h EVINRUDE:

0215869
 
0215869 H.O. WAVE, Stbd
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
Back to top