0215869 H.O. WAVE, Stbd EVINRUDE
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
H
Price: query
Rating:
Compatible models:
DE200HXAAA
DE200HXAAC
DE200HXAAD
DE200XCAAA
DE200XCAAC
DE200XCAAD
DE225CXAAA
DE225CXAAC
DE225CXAAD
DE225CXINS
DE225PXAAA
DE225PXAAC
DE225PXAAD
DE225PXINS
DE250CXAAA
DE250CXAAC
DE250CXAAD
DE250CXISF
DE250PXAAA
DE250PXAAC
DE250PXAAD
DE250PXISF
DE300CXAAA
DE300CXAAC
DE300CXAAD
DE300CXIIC
DE300CXINR
DE300CXISF
DE300CZIIC
DE300PXAAA
DE300PXAAC
DE300PXAAD
DE300PXIIC
DE300PXINR
DE300PXISF
E200DHXAAA
E200DHXAAC
E200DHXAAD
E200DHXSEA
E200HCXAAA
E200HCXAAC
E200HCXAAD
E200HCXSEA
E200HSLSEA
E225DCXAAA
E225DCXAAC
E225DCXAAD
E225DCXIID
E225DCXINS
E225DCXISE
E225DCXSEB
E225DHXIND
E225DPXAAA
E225DPXAAC
E225DPXAAD
E225DPXIID
E225DPXISE
E225DPXSEB
E225HSLISF
E225HSLSEC
E250DCXAAA
E250DCXAAC
E250DCXAAD
E250DCXISE
E250DCXSEB
E250DPXAAA
E250DPXAAC
E250DPXAAD
E250DPXISE
E250DPXSEB
E250HSLAAA
E250HSLAAC
E250HSLAAD
E250HSLSES
E300DCXAAA
E300DCXAAC
E300DCXAAD
E300DCXIIA
E300DCXISF
E300DCXSEC
E300DCZINM
E300DPXAAA
E300DPXAAC
E300DPXAAD
E300DPXIIA
E300DPXINM
E300DPXISF
E300DPXSEC
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- DECALS - White » 0215869
DE200HXAAD 2012
DE200XCAAA, DE200XCAAB 2012
DE200XCAAC 2012
DE200XCAAD 2012
DE225CXAAA, DE225CXAAB 2012
DE225CXAAC 2012
DE225CXAAD 2012
DE225CXINS 2012
DE225PXAAA, DE225PXAAB 2012
DE225PXAAC 2012
DE225PXAAD 2012
DE225PXINS 2012
DE250CXAAA, DE250CXAAB, DE250CZAAA, DE250CZAAB 2012
DE250CXAAC, DE250CZAAC 2012
DE250CXAAD, DE250CZAAD 2012
DE250CXISF, DE250CXISS, DE250CZISF, DE250CZISS 2010
DE250PXAAA, DE250PXAAB, DE250PZAAA, DE250PZAAB 2012
DE250PXAAC, DE250PZAAC 2012
DE250PXAAD, DE250PZAAD 2012
DE250PXISF, DE250PXISS, DE250PZISF, DE250PZISS 2010
DE300CXAAA, DE300CXAAB, DE300CZAAA, DE300CZAAB 2012
DE300CXAAC, DE300CZAAC 2012
DE300CXAAD, DE300CZAAD 2012
DE300CXIIC 2011
DE300CXINR, DE300CZINR 2012
DE300CXISF, DE300CXISG, DE300CXISS, DE300CZISF, DE300CZISG, DE300CZISS 2010
DE300CZIIC 2011
DE300PXAAA, DE300PXAAB, DE300PZAAA, DE300PZAAB 2012
DE300PXAAC, DE300PZAAC 2012
DE300PXAAD, DE300PZAAD 2012
DE300PXIIC, DE300PZIIC 2011
DE300PXINR, DE300PZINR 2012
DE300PXISF, DE300PXISG, DE300PXISS, DE300PZISF, DE300PZISG, DE300PZISS 2010
E200DHXAAA, E200DHXAAB, E200HSLAAA, E200HSLAAB 2012
E200DHXAAC, E200HSLAAC 2012
E200DHXAAD, E200HSLAAD 2012
E200DHXSEA, E200HVLSEC 2009
E200HCXAAA, E200HCXAAB 2012
E200HCXAAC 2012
E200HCXAAD 2012
E200HCXSEA 2009
E200HSLSEA 2009
E225DCXAAA, E225DCXAAB 2012
E225DCXAAC 2012
E225DCXAAD 2012
E225DCXIID, E225DCZIID 2011
E225DCXINS, E225DCZINS 2012
E225DCXISE, E225DCXISF, E225DCZISE, E225DCZISF 2010
E225DCXSEB, E225DCZSEB 2009
E225DHXIND, E225DPXINS, E225DPZINS, E225HSLINM 2012
E225DPXAAA, E225DPXAAB, E225HSLAAA, E225HSLAAB 2012
E225DPXAAC, E225HSLAAC 2012
E225DPXAAD, E225HSLAAD 2012
E225DPXIID, E225DPZIID, E225HSLIIA 2011
E225DPXISE, E225DPXISF, E225DPZISE, E225DPZISF 2010
E225DPXSEB, E225DPZSEB 2009
E225HSLISF, E225HSLISR 2010
E225HSLSEC 2009
E250DCXAAA, E250DCXAAB, E250DCZAAA, E250DCZAAB 2012
E250DCXAAC, E250DCZAAC 2012
E250DCXAAD, E250DCZAAD 2012
E250DCXISE, E250DCXISF, E250DCZISE, E250DCZISF 2010
E250DCXSEB, E250DCZSEB 2009
E250DPXAAA, E250DPXAAB, E250DPZAAA, E250DPZAAB 2012
E250DPXAAC, E250DPZAAC 2012
E250DPXAAD, E250DPZAAD 2012
E250DPXISE, E250DPXISF, E250DPZISE, E250DPZISF 2010
E250DPXSEB, E250DPZSEB 2009
E250HSLAAA, E250HSLAAB 2012
E250HSLAAC 2012
E250HSLAAD 2012
E250HSLSES 2009
E300DCXAAA, E300DCXAAB, E300DCZAAA, E300DCZAAB 2012
E300DCXAAC, E300DCZAAC 2012
E300DCXAAD, E300DCZAAD 2012
E300DCXIIA, E300DCZIIA 2011
E300DCXISF, E300DCXISG, E300DCXISR, E300DCZISF, E300DCZISG, E300DCZISR 2010
E300DCXSEC, E300DCZSEC 2009
E300DCZINM 2012
E300DPXAAA, E300DPXAAB, E300DPZAAA, E300DPZAAB, E300DSLAAA, E300DSLAAB 2012
E300DPXAAC, E300DPZAAC, E300DSLAAC 2012
E300DPXAAD, E300DPZAAD, E300DSLAAD 2012
E300DPXIIA, E300DPZIIA, E300DSLIIR 2011
E300DPXINM, E300DPZINM, E300DSLINA 2012
E300DPXISF, E300DPXISG, E300DPXISR, E300DPZISF, E300DPZISG, E300DPZISR, E300DSLISC, E300DSLISF, E300DSLISG 2010
E300DPXSEC, E300DPZSEC, E300DSLSES 2009
Information:
Protection Devices
The Caterpillar generator mounted control panel is equipped with protection devices to protect the engine while cranking.Batteries
Lights or buttons may indicate if a fault has occurred in the battery charging system causing the battery to be either undercharged or overcharged.Overcranking
A timer allows the engine to crank either once for 30 seconds, or to crank through 5 ten-second cranking cycles (depending upon the device used) while unattended. If the engine does not start before the time elapsed, the fuel system will be shutoff and a light will indicate a starting failure. Engine Operation
Prealarm systems provide an audible and/or a visual indication for low oil pressure, high water temperature, low fuel supply or low jacket water temperature before the condition becomes critical. These alarms are self resetting when the condition is corrected. The engine may also be equipped with shutdown devices. If low oil pressure, high jacket water temperature or an engine overspeed condition occurs, the engine will be shutdown and a corresponding button or light will indicate the cause of the shutdown. These devices must be reset after repairs have been made and before starting. See the topic, EMERGENCY SHUTOFF DEVICES AND ALARMS.Generator set control panels should be equipped with an ammeter, a frequency meter and a voltmeter. Depending upon the type of operation, the panel may also be equipped with other meters and lights. Know these instruments and their normal readings. They will indicate how the generator set is performing.Shutting Down
A timer allows the transfer switch to transfer the load to another source and to continue engine running for up to 2 minutes for cooling purposes before stopping.Engine Exerciser
At preset times, the exerciser will start, run and stop the engine in order to ensure both proper lubrication of all engine parts and proper equipment operation if and when the standby unit is needed.Become familiar with all instructions included with the equipment.Woodward Governors
Woodward Governors are usually electrically operated from a control panel.Generator Set Control Panel
The generator set control panel is located on top of the generator and is equipped with the following controls and gauges:Panel lights (1) are controlled by an ON/OFF switch (7). An ammeter (2), frequency meter (3) and a voltmeter (4) show the output of the generator. Two gauges (5 and 6) show engine oil pressure and water temperature respectively. The ammeter selector switch (12) gives the operator a choice of which phase (T1, T2 or T3) of the generator output the ammeter (2) will show. Voltage level rheostat (9) takes the place of the voltage level rheostat in the generator regulator assembly.The engine control switch (8) has four positions; MANUAL, AUTOMATIC, STOP and OFF. Placing the control in the MANUAL position will start the engine and allow the operator to manually connect the generator to the load. If the unit is used for standby application with a remote transfer switch, the AUTOMATIC position is used. In this position the engine will automatically start and take up the load when commercial power has stopped. Placing the control in the STOP or OFF position will stop the engine. When in the AUTOMATIC or MANUAL position, the engine will automatically stop if the commercial power has started or if the engne has a fault.The PSG governor control switch allows the operator to control the engine rpm from the panel. If the engine is equipped with glow plugs, they are controlled by an ON/OFF heat switch (15).If the engine has a fault, engine failure light/reset switch (11) will operate. The light/switch (11) will activate a shutdown relay to stop the engine. A shutdown indicator (14) will also operate to show the cause of the fault. The shutdown indicators (14) give an indication that the fault was either oil pressure, water temperature or overspeed. A fourth shutdown indicator will show an overcrank condition. A D.C. ammeter and a governor control switch will take the place of buttons (10 and 13) respectively if ordered. The shutdown indicators have four auxiliary contacts; one for each time its shutdown indicator operates. The contacts are connected to a remote annunciator panel if ordered.The shutdown indicator lights can be checked for malfunction by depressing the shutdown indicators. Replace burned out bulbs immediately.
CONTROL PANEL
1. Panel lights. 2. Alternating current ammeter. 3. Frequency meter. 4. Alternating current voltmeter. 5. Oil pressure gauge. 6. Water temperature gauge. 7. ON/OFF toggle switch for panel lights. 8. Engine control switch. 9. Voltage level rheostat. 10. Button (direct current ammeter if ordered). 11. Engine failure light/reset switch. 12. Ammeter selector switch. 13. Button (governor control switch if engine is equipped with a PSG governor). 14. Shutdown indicator (oil pressure, water temperature, overspeed and overcrank). 15. Button; heat switch (if so equipped). 16. Panel; prealarm module (if so equipped).Starting The Engine
1. Perform all prestart checks outlined previously.2. Place the CONTROL switch in the MANUAL position to crank the engine.3. When the engine starts and engine rpm reaches 600 rpm and the oil pressure registers 22 psi (1.5 kg/cm2) the starting motor will automatically disconnect from the start circuit.4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to the required instrument panel gauge readings.Stopping The Engine
1. Remove the load. See GENERATOR SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached.3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL marks on the side of the dipstick marked "CHECK WITH ENGINE RUNNING".4. Stop the engine.Solenoid Shutoff
a. Move the control switch to the STOP or OFF positions. (Do not confuse this with the "RAISE-LOWER" switch.)
ON-OFF-STOP SWITCHPSG Governor:
b. Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops.5. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE section.6. Drain the raw water system if below freezing temperatures are expected.7. Observe the Service Meter reading. Perform the
The Caterpillar generator mounted control panel is equipped with protection devices to protect the engine while cranking.Batteries
Lights or buttons may indicate if a fault has occurred in the battery charging system causing the battery to be either undercharged or overcharged.Overcranking
A timer allows the engine to crank either once for 30 seconds, or to crank through 5 ten-second cranking cycles (depending upon the device used) while unattended. If the engine does not start before the time elapsed, the fuel system will be shutoff and a light will indicate a starting failure. Engine Operation
Prealarm systems provide an audible and/or a visual indication for low oil pressure, high water temperature, low fuel supply or low jacket water temperature before the condition becomes critical. These alarms are self resetting when the condition is corrected. The engine may also be equipped with shutdown devices. If low oil pressure, high jacket water temperature or an engine overspeed condition occurs, the engine will be shutdown and a corresponding button or light will indicate the cause of the shutdown. These devices must be reset after repairs have been made and before starting. See the topic, EMERGENCY SHUTOFF DEVICES AND ALARMS.Generator set control panels should be equipped with an ammeter, a frequency meter and a voltmeter. Depending upon the type of operation, the panel may also be equipped with other meters and lights. Know these instruments and their normal readings. They will indicate how the generator set is performing.Shutting Down
A timer allows the transfer switch to transfer the load to another source and to continue engine running for up to 2 minutes for cooling purposes before stopping.Engine Exerciser
At preset times, the exerciser will start, run and stop the engine in order to ensure both proper lubrication of all engine parts and proper equipment operation if and when the standby unit is needed.Become familiar with all instructions included with the equipment.Woodward Governors
Woodward Governors are usually electrically operated from a control panel.Generator Set Control Panel
The generator set control panel is located on top of the generator and is equipped with the following controls and gauges:Panel lights (1) are controlled by an ON/OFF switch (7). An ammeter (2), frequency meter (3) and a voltmeter (4) show the output of the generator. Two gauges (5 and 6) show engine oil pressure and water temperature respectively. The ammeter selector switch (12) gives the operator a choice of which phase (T1, T2 or T3) of the generator output the ammeter (2) will show. Voltage level rheostat (9) takes the place of the voltage level rheostat in the generator regulator assembly.The engine control switch (8) has four positions; MANUAL, AUTOMATIC, STOP and OFF. Placing the control in the MANUAL position will start the engine and allow the operator to manually connect the generator to the load. If the unit is used for standby application with a remote transfer switch, the AUTOMATIC position is used. In this position the engine will automatically start and take up the load when commercial power has stopped. Placing the control in the STOP or OFF position will stop the engine. When in the AUTOMATIC or MANUAL position, the engine will automatically stop if the commercial power has started or if the engne has a fault.The PSG governor control switch allows the operator to control the engine rpm from the panel. If the engine is equipped with glow plugs, they are controlled by an ON/OFF heat switch (15).If the engine has a fault, engine failure light/reset switch (11) will operate. The light/switch (11) will activate a shutdown relay to stop the engine. A shutdown indicator (14) will also operate to show the cause of the fault. The shutdown indicators (14) give an indication that the fault was either oil pressure, water temperature or overspeed. A fourth shutdown indicator will show an overcrank condition. A D.C. ammeter and a governor control switch will take the place of buttons (10 and 13) respectively if ordered. The shutdown indicators have four auxiliary contacts; one for each time its shutdown indicator operates. The contacts are connected to a remote annunciator panel if ordered.The shutdown indicator lights can be checked for malfunction by depressing the shutdown indicators. Replace burned out bulbs immediately.
CONTROL PANEL
1. Panel lights. 2. Alternating current ammeter. 3. Frequency meter. 4. Alternating current voltmeter. 5. Oil pressure gauge. 6. Water temperature gauge. 7. ON/OFF toggle switch for panel lights. 8. Engine control switch. 9. Voltage level rheostat. 10. Button (direct current ammeter if ordered). 11. Engine failure light/reset switch. 12. Ammeter selector switch. 13. Button (governor control switch if engine is equipped with a PSG governor). 14. Shutdown indicator (oil pressure, water temperature, overspeed and overcrank). 15. Button; heat switch (if so equipped). 16. Panel; prealarm module (if so equipped).Starting The Engine
1. Perform all prestart checks outlined previously.2. Place the CONTROL switch in the MANUAL position to crank the engine.3. When the engine starts and engine rpm reaches 600 rpm and the oil pressure registers 22 psi (1.5 kg/cm2) the starting motor will automatically disconnect from the start circuit.4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to the required instrument panel gauge readings.Stopping The Engine
1. Remove the load. See GENERATOR SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached.3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL marks on the side of the dipstick marked "CHECK WITH ENGINE RUNNING".4. Stop the engine.Solenoid Shutoff
a. Move the control switch to the STOP or OFF positions. (Do not confuse this with the "RAISE-LOWER" switch.)
ON-OFF-STOP SWITCHPSG Governor:
b. Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops.5. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE section.6. Drain the raw water system if below freezing temperatures are expected.7. Observe the Service Meter reading. Perform the
Parts h EVINRUDE:
0215868
0215868 H.O. WAVE, Port
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD