0305381 EVINRUDE HANDLE, Starter


0305381 HANDLE, Starter EVINRUDE 33002M, 33802M, 33902A, 40002A, 40052A, 40102B, 40802A, 40852A, 40902R, 40952R HANDLE
0305381 HANDLE, Starter EVINRUDE
Rating:
73

Buy HANDLE, Starter 0305381 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 9
 

BRP EVINRUDE entire parts catalog list:

33002M, 33003M, 33052M, 33053M 1970
33802M, 33802R, 33803M, 33803R, 33852M, 33852R, 33853M, 33853R 1968
33902A, 33903A, 33952A, 33953A 1969
40002A, 40003A 1970
40052A, 40053A 1970
40102B, 40102G, 40103B, 40103G, 40152B, 40152G, 40153B, 40153G 1971
40802A, 40802D, 40802S, 40803A, 40803D, 40803S 1968
40852A, 40852C, 40852D, 40852S, 40853A, 40853C, 40853D, 40853S 1968
40902R, 40903R 1969
40952R, 40953R 1969

Information:


Illustration 1 g06387173
Left side view
(1) Mixing manifold
(2) EGR control valve
(3) EGR venturi
(4) Electronic Control Module (ECM)
(5) Flywheel housing
(6) Oil Pan
(7) Fuel transfer pump
(8) Vibration damper
Illustration 2 g06387176
Right side view
(9) Exhaust manifold
(10) Turbocharger
(11) Temperature regulator housing
(12) Water pump
(13) Oil filter
(14) EGR cooler
(15) Balance valve actuatorThe C15 is an in-line six cylinder engine. The C15 has a bore of 137.2 mm (5.40 inch) and a stroke of 171.5 mm (6.75 inch). The displacement of the engine is 15.2 L (927.56 cu in). Each cylinder has two inlet valves and two exhaust valves. The firing sequence of the engine is 1-5-3-6-2-4.The C18 is an in-line six cylinder engine. The C18 has a bore of 145 mm (5.7 inch) and a stroke of 183 mm (7.2 inch). The displacement of the engine is 18.1 L (1102.36 cubic inch). Each cylinder has two inlet valves and two exhaust valves. The firing sequence of the engine is 1-5-3-6-2-4.Starting the Engine
The Electronic Control Module (ECM) will automatically provide the correct amount of fuel that is necessary to start the engine. The throttle should not be held while the engine is being cranked. If the engine fails to start in 30 seconds, the starter switch should be released. The starting motor should be allowed to cool for 2 minutes before being used again.
Excessive ether (starting fluid) can cause piston and ring damage. Use ether for cold weather starting purposes only.
Cold Mode Operation
Starting the engine and operation in cold weather is dependent on the type of fuel used, the oil viscosity, and other optional starting aids. For more information, refer to the Operation and Maintenance Manual, "Cold Weather Operation".The Cold Mode flag in Caterpillar Electronic Technician (ET) indicates that the engine system is compensating with a cold mode strategy.Some examples of a cold mode strategy may include:
Elevated RPM
Timing enhancements
Fuel injection enhancementsTroubleshooting performance-related problems when the Cold Mode flag is active is not recommended.The Cold Mode flag will activate in the following conditions:
Coolant temperature is less than 35° C (95° F)
Coolant temperature is less than 75° C (167° F) and EGR gas temperature is less than 35° C (95° F)
Coolant temperature is less than 75° C (167° F) and EGR gas temperature is less than 65° C (149° F)Once coolant temperature is above 75° C (167° F) and EGR gas temperature is greater than 65° C (149° F) for 10 minutes, no cold mode strategy will be active.Customer Specified Parameters
The engine can be programmed for several customer specified parameters. For a brief explanation of each customer specified parameter, refer to the Operation and Maintenance Manual.Delayed Engine Shutdown (If Equipped)
The "Delayed Engine Shutdown" strategy allows the engine to run for a time after the engine start switch key is turned to the OFF position to cool the engine and system components. The engine start switch key may be removed.Note: There may be regulations that define the requirements for the operator and/or support personnel to be present when the engine is running.Note: The DEF purge process will run for 2 minutes once the engine is shutdown and must complete. The purge process may occur during "Delayed Engine Shutdown". It is important not to turn the battery disconnect switch OFF during the purge process. Do not turn the battery power disconnect switch OFF until battery disconnect switch indicator lamp has turned OFF. If the purge process does not complete, a diagnostic code will become active.
Leaving the machine unattended when the engine is running may result in personal injury or death. Before leaving the machine operator station, neutralize the travel controls, lower the work tools to the ground and deactivate all work tools, and place the lever for the hydraulic lockout control in the LOCKED position.
Note: Leaving the engine unattended while running may result in property damage in the event of a malfunction.Delayed Engine Shutdown Lamp
Illustration 3 g03572624The Delayed Engine Shutdown strategy will run whenever the DPF outlet temperature is above a threshold at engine shutdown. The temperature needs to drop below that threshold before Delayed Engine Shutdown will end. There is a parameter in Cat ET, "Delayed Engine Shutdown Aftertreatment Outlet Gas Temperature Threshold" which can be configured between 200° C (392° F) and 575° C (1067° F). The default setting is engine iron set or application specific and originally set by the product group. Only an authorized dealer using passwords through Caterpillar's Feature Protection System (FPS) can change the threshold. When the estimated DPF outlet temperature drops below the programmed value, the DES will end and the engine will shutdown. There is also a "Delayed Engine Shutdown Maximum Time" parameter in Cat ET. This will shutdown DES once the threshold time is met regardless if it has dropped below the temperature threshold. The minimum time it can be set to is 7 minutes (default) for machine engine customers and 4 minutes for commercial engine customers. The maximum time it can be set to is 30 minutes. Once programmed in the factory the time can only be increased with FPS by an authorized dealer. (i.e. if it comes programmed at 20 minutes, a dealer can only increase it up to 30, can not lower it below 20). Once Delayed Engine Shutdown begins, it will always run for a minimum of 76 seconds even if temperature drops below threshold before that.When the engine start switch key is turned to the OFF position and delayed engine shutdown is active, the "Delayed Engine Shutdown" lamp will illuminate and/or the following text will be displayed on the dash: Engine Cooldown Active.Note: There is either a STOP (1) orDELAYED ENGINE SHUTDOWN (1A) position on the key switch. To override delayed engine shutdown and stop the engine, turn the engine start switch key to the STOP (1) or DELAYED ENGINE SHUTDOWN (1A) position. Overriding the delayed engine shutdown may reduce engine and system component life. A warning message and/or audible alarm will be initiated and a fault code will be logged for improper engine shutdown.
Illustration 4 g03740759


Parts handle EVINRUDE:

0204800
 
0204800 HANDLE, Tilting
18002C, 18802A, 18902B, 25002C, 25902B, 33002M, 33802M, 33902A, 40002A, 40052A, 40072A, 40102B, 40972R
0380330
 
0380330 HANDLE, Geashift
33002M, 33802M, 33902A, 40102B
0204877
HANDLE, Front latch
0204877 HANDLE, Front latch
33002M, 33802M, 33902A, 40002A, 40052A, 40072A, 40102B, 40802A, 40852A, 40872A, 40902R, 40952R, 40972R
0305409
 
0305409 HANDLE
40102B, 40202E, 50202C