0318213 EVINRUDE HANDLE, Steering, inner half


0318213 HANDLE, Steering, inner half EVINRUDE 18304A, 25302A, 25402M, 25502B, 25602E, 25702H, 35602G, 6302S, 6402C, 6504R, 6604A, 6704M, 6804B, 6904E HANDLE
0318213 HANDLE, Steering, inner half EVINRUDE
Rating:
28

Buy HANDLE, Steering, inner half 0318213 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$37.50
 

13-04-2022
1.0[0.45] Pounds
-: -
Johnson Evinrude OMC New OEM Steering/Tiller Half Handle, 0318213
Sold Individually || Sold Each || Please verify your own fitment
Number on catalog scheme: 94
 

BRP EVINRUDE entire parts catalog list:

18304A, 18305A 1973
25302A, 25303A, 25352A, 25353A 1973
25402M, 25403M, 25452M, 25453M 1974
25502B, 25503B, 25552B, 25553B 1975
25602E, 25603E, 25652E, 25653E 1976
25702H, 25702S, 25703H, 25703S, 25752H, 25752S, 25753H, 25753S, 35702C, 35702H, 35703C, 35703H, 35752C, 35752H, 35753C, 35753H 1977
35602G, 35602S, 35603G, 35603S, 35652G, 35652S, 35653G, 35653S 1976
6302S, 6303S 1973
6402C, 6403C 1974
6504R, 6505R 1975
6604A, 6605A 1976
6704M, 6705M 1977
6804B, 6805B 1978
6904E, 6905E 1979

Information:


Table 1
Recommended Inlet Manifold Pressure    
Engine RPM     Inlet Manifold Pressure (1)    
900    
40 5 kPaa (5.8 .7 psia)    
1000    
50 5 kPaa (7.3 .7 psia)    
( 1 ) kPaa is kilopascal measured in absolute pressure.These recommended values are provided for reference only. Parasitic loads affect the required inlet manifold pressure. The engine choke trim can and should be adjusted to a manifold pressure level that provides the optimum engine stability and the load acceptance capability for the specific application of the engine.Use the following guidelines for the proper adjustment of the choke trim.
The choke trim should be adjusted in order to get an average exhaust port temperature of 500 to 550°C (932 to 1022°F) when the engine is operating below 40 percent load.
If the wastegate is in the closed position, the engine may be over choked. The choke trim setting on the DDT needs to be made more negative in order to reduce the choking. This will permit the wastegate to help control the desired air fuel ratio.
If the exhaust port temperatures are all lower than 500°C (932°F), then the engine is operating too lean. This can result in a high rate of cylinder misfires. The choke trim on the DDT needs to be made more positive in order to increase the choking.
The maximum exhaust port temperature should not exceed 600°C (1112°F). If the exhaust port temperatures are higher than 600°C (1112°F), the engine is not getting enough air. This can result in detonation and/or component thermal degradation. The choke trim needs to be made more negative in order to reduce the amount of choking. If only one cylinder exhaust port temperature is exceeding 600°C (1112°F), then investigate for a mechanical problem with that cylinder.Electronic Choke Trim Procedure
Set the engine operating condition to the rated speed and no load (or minimum load possible).
Connect the DDT to the Engine Supervisory System (ESS). Display the DDT screen "number 33" by pressing the "SELECT MODE" key in order to display the "CSP MENU" (customer selectable parameters) screen "number 03". Then press the "SELECT FUNC" key to display screen "number 33". Or simply enter the "number 33" and then press the "ENTER" key.Screen "number 33" on the DDT will display the following:"CHOKE TRIM""00 40/0900 33<"The numbers on the second line of the display are: The choke trim "OFFSET" number which indicates the amount of offset that has been entered through the "ALT1" and the "ALT2" keys. The amount of the choke trim offset "00" represents the factory default setting. "40/0900" represents the Inlet Manifold Pressure (kPaa)/Engine speed (rpm).Note: kPaa is kilopascal measured in absolute pressure.
On the DDT screen "number 33", when the "ALT1" or "ALT2" keys are pressed, a command signal is sent to the choke actuator in order to change the position of the choke plate.To raise the inlet manifold pressure, press the "ALT2" key. (The offset number on the DDT screen will decrease by one every time the "ALT2" key is pressed.)To lower the inlet manifold pressure, press the "ALT1" key. (The offset number on the DDT screen will increase by one every time the "ALT1" key is pressed.)This process should


Parts handle EVINRUDE:

0205971
 
0205971 HANDLE
10424G, 15404G, 50202C, 50902C, 5802B, 6002B, 6102E, 6202D, 6302S, 6402C, 6802A, 6902M, 9022A, 9122R, 9222M, 9322B, 9822D, 9922S
0312184
 
0312184 HANDLE,Latch
5802B, 6002B, 6102E, 6202D, 6302S, 6402C, 6504R, 6604A, 6704M, 6802A, 6804B, 6902M, 6904E, 9022A, 9122R, 9222M, 9322B, 9822D, 9922S
0206648
 
0206648 HANDLE, Starter
18102S, 18202R, 18304A, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25904R, 35602G, E25CNE, E25ECIB, E25ECTD, E25RCSA, E25RSA, E25RSLS, E35ECIG, E35ECND, E35ECSM, E35ECTS
0318214
 
0318214 HANDLE, Steering, outer half
18304A, 25302A, 25402M, 25502B, 25602E, 25702H, 35602G, 6302S, 6504R, 6604A, 6704M, 6804B
0385837
 
0385837 HANDLE, Gearshaft
6302S, 6402C, 6504R, 6604A, 6704M, 6804B
0207555
 
0207555 HANDLE,Starter
10524C, 10624G, 10724A, 10824M, 15504C, 15604A, 6504R, 6604A, 6704M
0321318
HANDLE, Latch
0321318 HANDLE, Latch
25702H, 25802C, 25904R, 35602G, E20CRCOS, E25CNE, E25ECIB, E25ECOC, E25ECRS, E25ECTD, E25RCSA, E25RSA, E25RSLS, E25RWCOS, E25RWCRD, E30ECOA, E30ECRR, E35ECIG, E35ECND, E35ECRR, E35ECSM, E35ECTS
0324513
 
0324513 HANDLE, Starter
10924B, 2802R, 2902A, 4806E, 4904D, 6804B, 6904E, E10ECSE, E15ECSD, E2RCSM, E4RLCSS, E5RCSS, E8RCSS
Back to top