0123238 HOUSING,Upper EVINRUDE
E10ELCRA, E10ELCTC, E125ESXESS, E125ESXW, E15ECRM, E15ECTR, E25RWCUR, E25RWEIM, E25RWESA, E25RWK, E30ECDM, E30ECOA, E30ECRR, E35ECRR, E35ECTS, E35RCDM, E40RSLR, E40RWCDB, E40RWCOM, E40RWCRA, E45RCCDS, E45RCE, E45RCEIA, E45RCESR, E55RSLN, E55RWLCDC, E
HOUSING
Price: query
Compatible models:
E10ELCRA
E10ELCTC
E125ESXESS
E125ESXW
E15ECRM
E15ECTR
E25RWCUR
E25RWEIM
E25RWESA
E25RWK
E30ECDM
E30ECOA
E30ECRR
E35ECRR
E35ECTS
E35RCDM
E40RSLR
E40RWCDB
E40RWCOM
E40RWCRA
E45RCCDS
E45RCE
E45RCEIA
E45RCESR
E55RSLN
E55RWLCDC
E55RWLCOS
E55RWLCRD
E55RWLE
E55RWLEIA
E55RWLESR
E65WMLEIB
E65WMLESM
E65WMLZ
M55RWLR
R45RCLR
T65WMLM
U25RWA
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- FUEL TANK - ASIA MARKET ONLY » 0123238
E125ESXESS 1990
E125ESXW 1989
E15ECRM, E15ELCRM, E15RCRM, E15RLCRM 1984
E15ECTR, E15ELCTR, E15RCTA, E15RCTR, E15RLCTA, E15RLCTR 1983
E25RWCUR, E25RWLCUR 1987
E25RWEIM, E25RWLEIM 1991
E25RWESA, E25RWLESA 1990
E25RWK, E25RWLK 1989
E30ECDM, E30ELCDM, E30RCDM, E30RLCDM, E30TECDM, E30TELCDM 1986
E30ECOA, E30ELCOA, E30RCOA, E30RLCOA, E30TECOA, E30TELCOA 1985
E30ECRR, E30ELCRR 1984
E35ECRR, E35ELCRR, E35RCRR, E35RLCRR, E35TELCRR 1984
E35ECTS, E35ELCTS, E35RCTS, E35RLCTS, E35TELCTS 1983
E35RCDM, E35RLCDM 1986
E40RSLR, E40RSR, E40RWLCTR, E40RWLTR 1983
E40RWCDB, E40RWLCDB 1986
E40RWCOM, E40RWLCOM 1985
E40RWCRA, E40RWLCRA 1984
E45RCCDS, E45RCLCDS 1986
E45RCE, E45RCLE, E45WMLE 1989
E45RCEIA, E45RCLEIA, E45WMLEIA 1991
E45RCESR, E45RCLESR, E45WMLESR 1990
E55RSLN, E55RSLN-2, E55RSN, E55RSN-2, E55RSYN, E55RSYN-2 1983
E55RWLCDC 1986
E55RWLCOS 1985
E55RWLCRD 1984
E55RWLE 1989
E55RWLEIA 1991
E55RWLESR 1990
E65WMLEIB 1991
E65WMLESM 1990
E65WMLZ 1989
M55RWLR 1988
R45RCLR, R45RCR 1988
T65WMLM 1988
U25RWA, U25RWLA 1988
Information:
Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
1491-3 Right Turbo Turbine Inlet Temperature Sensor voltage above normal The ECM detects a duty cycle that is greater than 96 percent for ten seconds. The code is logged.
If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
1491-4 Right Turbo Turbine Inlet Temperature Sensor voltage below normal The ECM detects a duty cycle that is less than 4 percent for ten seconds.
1491-8 Right Turbo Turbine Inlet Temperature Sensor abnormal frequency, pulse width, or period The ECM detects a sensor frequency that is greater than 600 Hz or less than 400 Hz.
1492-3 Left Turbo Turbine Inlet Temperature Sensor voltage above normal The ECM detects a duty cycle that is greater than 96 percent for ten seconds. The code is logged.
If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
1492-4 Left Turbo Turbine Inlet Temperature Sensor voltage below normal The ECM detects a duty cycle that is less than 4 percent for ten seconds.
1492-8 Left Turbo Turbine Inlet Temperature Sensor abnormal frequency, pulse width, or period The ECM detects a sensor frequency that is greater than 600 Hz or less than 400 Hz. System OperationUse this procedure to troubleshoot any suspect problems with the sensor for the left turbocharger turbine inlet temperature or the right turbocharger turbine inlet temperature.The Pulse Width Modulated Sensor (PWM) provides a signal to the engine's ECM. The PWM signal is used to represent certain engine operating conditions. The sensors receive 8.0 0.4 VDC from a regulated power supply.The ECM performs an automatic calibration of these sensors whenever the ECM is powered and the engine has been off for at least five seconds.The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.The following components can cause problems with the power supply:
Electrical connector or wiring
Sensor
ECMThe most likely cause of a problem is a problem with an electrical connector or wiring. The least likely cause is a problem with the ECM.
Illustration 1 g01534113
Schematic of the PWM sensors for the sensor signal circuit
Illustration 2 g01534075
Location of the connectors that are for the PWM sensor circuit (top side engine view)
(1) Sensor for the right turbocharger turbine inlet temperature
(2) Sensor for the left turbocharger turbine inlet temperature
(3) Right rail connector
(4) Left rail connector
(5) J1/P1 ECM connector
(6) J2/P2 ECM connector
Illustration 3 g01279964
Terminal locations at the P1 ECM connector that are for the sensors for the turbocharger turbine inlet temperature
(P1-5) Digital return
(P1-18) Digital return
Illustration 4 g01279871
Terminal locations at the P2 ECM connector that are for the sensors for the turbocharger turbine inlet temperature
(P2-29) Digital supply
(P2-65) Left turbocharger turbine inlet temperature
(P2-73) Right turbocharger turbine inlet temperature
(P2-92) Digital return
Illustration 5 g01826777
Terminal locations at the left rail connector that are for the sensors for the turbocharger turbine inlet temperature
(Terminal 49) Left turbocharger turbine inlet temperature
(Terminal 63) Digital supply
(Terminal 69) Digital return
Illustration 6 g01534394
Terminal locations at the right rail connector that are for the sensors for the turbocharger turbine inlet temperature
(Terminal 49) Right turbocharger turbine inlet temperature
(Terminal 63) Digital supply
(Terminal 69) Digital return
Illustration 7 g01240891
Sensor connector
(Terminal 1) Sensor supply
(Terminal 2) Sensor return
(Terminal 3) Signal Test Step 1. Check for an "Active" Diagnostic Code
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Monitor the diagnostic codes on Cat ET. Check and record any diagnostic codes. Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Determine if a diagnostic code has occurred several times. Note: A diagnostic code that is logged several times is an indication of an intermittent problem. Most intermittent problems are the result of a bad connection between a socket and a pin in a connector or a bad connection between a wire and a terminal.
Look for one or more of the following diagnostic codes that are active or logged:
1491-03
1491-04
1491-08
1492-03
1492-04
1492-08Expected Result:No diagnostic code is active for the exhaust temperature sensors.Results:
OK - No diagnostic codes are active.Repair: There may be an intermittent problem in the harness or in a connector. If an intermittent
Parts housing EVINRUDE:
0581778
0581778 HOUSING,Rectifier and lead assembly
10724A, 10824M, 10924B, 25702H, 25802C, 25904R, 50902C, 55874S, BE20SEECB, BE20SEEDA, BE20SEEUM, BE25EECE, BE25EEDM, BE25EEUB, BE30EECS, BE30EEDE, BE30EEUD, E10ECCD, E10ECDB, E10ECES, E10ECOM, E10ECSE, E10ECUE, E10EEIR, E10EENA, E10EESC, E10ELCID, E1
0323109
0323109 HOUSING,Lower mount,stbd.
25702H, 25802C, 25904R, B25JREUR, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25BAECM, BE25BAEDR, BE25EECE, BE25EEDM, BE25EEUB, BE30BAECS, BE30BAEDE, BE30BAEEC, BE30BAEUD, BE30BASIA, BE30BASSR, BE30EECS, BE30EEDE, BE30EEUD, E2
0323108
0323108 HOUSING,Lower mount,port
25702H, 25802C, 25904R, B25JREUR, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25BAECM, BE25BAEDR, BE25EECE, BE25EEDM, BE25EEUB, BE30BAECS, BE30BAEDE, BE30BAEEC, BE30BAEUD, BE30BASIA, BE30BASSR, BE30EECS, BE30EEDE, BE30EEUD, E2
0390613
0330560
0330560 HOUSING, Impeller
E25RWCDC, E25RWCOS, E25RWCUR, E25RWEDC, E25RWEIM, E25RWENB, E25RWEOS, E25RWERD, E25RWESA, E25RWETE, E25RWEUR, E25RWK, E28ELCDS, E28ELCDS, E28ESLCCR, E28ESLCCR, E28ESLCEA, E28ESLCEA, E28ESLCUC, E28ESLCUC, E28ESLEDR, E28ESLEDR, E28ESLEIB, E28ESLEIB, E2
0397221
0397221 HOUSING & COVER ASSY.
C155WTLM, CE275TLCDC, CE300TLCDC, E100STLCCA, E100WMLCDR, E100WTLCUA, E110MLCCA, E110MLCDC, E110MLCUR, E120TLCCA, E120TLCDC, E120TLCUR, E140CXCCS, E140TLCDC, E140TLCUA, E150CXCCA, E150STLCCA, E150STLCDC, E150STLCUR, E150TLCDC, E150TLCUR, E155WTLCDR,
0397186
0432319
0432319 HOUSING AY
E40ECEC, E45RCE, E45RCESR, E48ESLCER, E48ESLCER, E50BECEC, E50TELCEC, E55RWLE, E55RWLESR, VE48ESLCER