0389922 EVINRUDE HOUSING & COVER ASSY


0389922 HOUSING & COVER ASSY EVINRUDE 100990S, 150940C, 50902C, 70973R, E100MLCSC, E115MLCIH, E115MLCSA, E140MLCIH, E140MLCSA, E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200TRLCIB, E200TRLCSF, E235TRLCIB, E235TRLCSM, E50BECIC, E50ECSR, E55RCIM, E55RLCSA, E60ECIA, E60ECSR, E70ELCIH, HOUSING
0389922 HOUSING & COVER ASSY EVINRUDE
Rating:
83

Buy HOUSING & COVER ASSY 0389922 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 18
 

BRP EVINRUDE entire parts catalog list:

100990S, 100993S, 100999S, 115990R, 115993R, 115999R, 140940R, 140943R, 140983R, 85990R, 85995R, 85999R 1979
150940C, 150949C, 175940R, 175949R, 200490A, 200940A, 200949A, 235940A, 235949A 1979
50902C, 50903C, 55974C, 55975C 1979
70973R, 75942R, 75943R 1979
E100MLCSC, E100TLCSC, E100TXCSC 1980
E115MLCIH, E115MLCIM, E115TLCIH, E115TLCIM, E115TXCIH, E115TXCIM 1981
E115MLCSA, E115TLCSA, E115TXCSA 1980
E140MLCIH, E140MLCIM, E140TRLCIH, E140TRLCIM, E140TRXCIH, E140TRXCIM 1981
E140MLCSA, E140TRLCSA, E140TRXCSA 1980
E150TRLCIA, E150TRLCIH, E150TRXCIA, E150TRXCIH 1981
E150TRLCSF, E150TRLCSR, E150TRXCSF, E150TRXCSR 1980
E175TRLCIM, E175TRXCIH, E175TRXCIM 1981
E175TRLCSA, E175TRLCSF, E175TRXCSA, E175TRXCSF 1980
E200TRLCIB, E200TRLCIH, E200TRXCIB, E200TRXCIH 1981
E200TRLCSF, E200TRLCSM, E200TRXCSF, E200TRXCSM 1980
E235TRLCIB, E235TRLCIH, E235TRXCIB, E235TRXCIH 1981
E235TRLCSM, E235TRXCSM 1980
E50BECIC, E50BELCIC 1981
E50ECSR, E50ELCSR 1980
E55RCIM, E55TLCIM 1981
E55RLCSA 1980
E60ECIA, E60ECIH, E60ELCIA, E60ELCIH, E60TLCIA, E60TLCIH 1981
E60ECSR, E60ELCSR 1980
E70ELCIH, E70ELCIM, E70TLCIM 1981
E70ELCSA 1980
E75ERCIH, E75ERCIM, E75ERLCIH, E75ERLCIM, E75TRLCIH, E75TRLCIM 1981
E75ERCSA, E75ERLCSA, E75TRLCSA 1980
E85MLCSA, E85STLCSA, E85STXCSA 1980
E90MLCIH, E90MLCIM, E90TLCIH, E90TLCIM, E90TXCIH, E90TXCIM 1981

Information:


Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service) , and either locked out or tagged DO NOT OPERATE.
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground. This connection is the first connection that is made at the installation. This connection is the last connection that should be removed. If the generator set is on flexible mounting pads, the ground connection must be flexible in order to avoid possible breakage in later operation.Ground connection cable or straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Joints that are silver soldered and bolted are preferred.Neutral Connections
The generators with a Wye Configuration usually have the neutral ground when the generator is installed. Grounding the neutral is for preventing damage to equipment.If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker. Also, the excessive current will cause the generator voltage to collapse. The result depends on the following items: electrical characteristics of the generator , type of fault and trip rating of the circuit breaker. An undervoltage device may be required in order to provide an adequate short circuit protection.There are some cases when the neutral wire is not grounded. An ungrounded generator neutral lead is acceptable when the possibility of grounds to the phase leads has been eliminated. An example of such measures are ground fault protective circuits. Ground fault protection requires the entire group of distribution circuits to be treated as a system. The owner should contact a certified consultant if a new distribution system is being developed. The owner should also contact a certified consultant if an existing system should be modified for the ground fault protection. Single Units
Each unit should be connected to a common ground.In a three-phase, four-wire system, the neutral wire should be grounded according to local wiring codes. Be sure to check your local wiring codes.Connection Diagrams
The connections are located in the enclosure for the control panel.Change the position of the wire terminals in order to modify the connection. The code for the winding is specified on the nameplate.Wiring Code A for Three-Phase Configuration
Illustration 1 g00952030
Illustration 2 g00952058
Factory connection for "A" wiring code
Table 1
L-L Voltage for Wiring Code A
Winding 50 Hz 60 Hz
6 190-208 190-240
7 220-230 -
8 - 190-208 R 230 voltage sensing - 0 => (T8) / 110 V => (T11)R 438 LS voltage sensing - 0 => (T3) / 220 V => (T2)Wiring Code B for Single-Phase Configuration or Three-Phase Configuration
Illustration 3 g00952097
Illustration 4 g00952196
Factory connection for "B" wiring code


Parts housing EVINRUDE:

0309474
 
0309474 HOUSING
100882B, 100990S, 115890C, 150840S, 150940C, 55872A, 55972A, 65832B, 85852A, 85892A, BE50DTLEDC, BE60ELEDR, BE70ELEDA, C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100MLCSC, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E1
0313113
 
0313113 HOUSING
100882B, 115890C, 150840S, 55872A, 55972A, 65832B, 85852A, 85892A, C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100MLCSC, E100STLCCA, E100STLCEM, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLESM, E100WTLZ, E110MLCC
0581778
HOUSING,Rectifier and lead assembly
0581778 HOUSING,Rectifier and lead assembly
10724A, 10824M, 10924B, 25702H, 25802C, 25904R, 50902C, 55874S, BE20SEECB, BE20SEEDA, BE20SEEUM, BE25EECE, BE25EEDM, BE25EEUB, BE30EECS, BE30EEDE, BE30EEUD, E10ECCD, E10ECDB, E10ECES, E10ECOM, E10ECSE, E10ECUE, E10EEIR, E10EENA, E10EESC, E10ELCID, E1
0389455
HOUSING AND BEARING ASSY
0389455 HOUSING AND BEARING ASSY
150940C, BE115ELEDR, BE115ELEUA, BE115GLECM, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE225CXECS, BE225CXEDE, BE225CXEUD, BE90ELEDR, BE90ELEUA, BE9
0326065
 
0326065 HOUSING,Starter
E35AELCDE, E40ECDE, E40ECOB, E40ECRM, E45RCCDS, E50BECDE, E50BECIC, E55RCIM, E55RLCSA, E55RSLN, E55RWLCDC, E55RWLCOS, E55RWLCRD, E60ECIA, E60ECSR, E65RWLCDR, E65RWLCOC, E65RWLCRS
0511806
 
0511806 HOUSING
E115MLCIH, E115MLCNB, E140MLCIH, E140MLCNB, E150ANCRS, E150STLCOH, E150STLCTE, E150TLCOS, E150TLCRD, E150TRLCIA, E150TRLCNM, E150TRLCTB, E175TLCOC, E175TRLCIM, E175TRLCNB, E175TRLCTD, E185TLCOC, E185TLCRS, E200TRLCIB, E200TRLCNE, E200TRLCTD, E235STLC
Back to top