0350668 EVINRUDE *INSULATION, Sound - (DE, DP Models)


0350668 *INSULATION, Sound - (DE, DP Models) EVINRUDE E40DELSDA, E40DELSOR, E40DELSRC, E40DPLAAA, E40DPLABA, E40DPLIIS, E40DPLINC, E40DPLISD, E40DPLISF, E40DPLSCB, E40DPLSDA, E40DPLSEE, E40DPLSOR, E40DPLSRC, E40DPLSUM, E40DRLABA, E40DRLSOR, E40DRLSRC, E40DTLAAA, E40DTLABA, E40DTLIIA, E40DTLINM, E40DTLIS INSULATION
0350668 *INSULATION, Sound - (DE, DP Models) EVINRUDE
Rating:
13

Buy *INSULATION, Sound - (DE, DP Models) 0350668 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 5
 

BRP EVINRUDE entire parts catalog list:

E40DELSDA 2006
E40DELSOR 2004,2005
E40DELSRC 2004
E40DPLAAA, E40DSLAAA 2012
E40DPLABA, E40DSLABA 2012
E40DPLIIS, E40DSLIIA 2011
E40DPLINC, E40DSLINM 2012
E40DPLISD, E40DSLISR 2010
E40DPLISF, E40DSLISF 2010
E40DPLSCB, E40DSLSCS 2008
E40DPLSDA 2006
E40DPLSEE, E40DSLSEC 2009
E40DPLSOR 2004,2005
E40DPLSRC 2004
E40DPLSUM 2007
E40DRLABA, E40DRMLABA 2012
E40DRLSOR 2004,2005
E40DRLSRC 2004
E40DTLAAA 2012
E40DTLABA 2012
E40DTLIIA 2011
E40DTLINM 2012
E40DTLISF 2010
E40DTLISR 2010
E40DTLSCS 2008
E40DTLSEC 2009
E50DPLAAA, E50DSLAAA 2012
E50DPLABA, E50DSLABA 2012
E50DPLIIS, E50DSLIIA 2011
E50DPLINC, E50DSLINM 2012
E50DPLISD, E50DSLISR 2010
E50DPLISF, E50DSLISF 2010
E50DPLSCB, E50DSLSCS 2008
E50DPLSDA 2006
E50DPLSEE, E50DSLSEC 2009
E50DPLSOR 2004,2005
E50DPLSRC 2004
E50DPLSUM 2007
E50DTLAAA 2012
E50DTLABA 2012
E50DTLIIA 2011
E50DTLINM 2012
E50DTLISF 2010
E50DTLISR 2010
E50DTLSCS 2008
E50DTLSEC 2009
E60DPLAAA, E60DSLAAA 2012
E60DPLABA, E60DSLABA 2012
E60DPLIIS, E60DSLIIA 2011
E60DPLINC, E60DSLINM 2012
E60DPLISD, E60DSLISR 2010
E60DPLISF, E60DSLISF 2010
E60DPLSCB, E60DSLSCS 2008
E60DPLSDA 2006
E60DPLSEE, E60DSLSEC 2009
E60DPLSUM 2007
E60DTLAAA 2012
E60DTLABA 2012
E60DTLIIA 2011
E60DTLINM 2012
E60DTLISF 2010
E60DTLISR 2010
E60DTLSCS 2008
E60DTLSEC 2009
E60WDRLSOS, E60WDRYSOS 2004,2005
E65WDRLINM, E65WDRYINM 2012

Information:


Table 1
Diagnostic Codes Table
Code and Description Conditions which Generate this Code System Response
262-3 5 Volt Sensor DC Power Supply : Voltage Above Normal The analog sensor supply voltage is above normal for one second. The code is logged.
All sensors are set to default values.
262-4 5 Volt Sensor DC Power Supply : Voltage Below Normal The analog sensor supply voltage is below normal for one second.
2131-3 5 Volt Sensor DC Power Supply #2 : Voltage Above Normal The analog sensor supply voltage is above normal for one second. The code is logged.
All sensors are set to default values.
2131-4 5 Volt Sensor DC Power Supply #2 : Voltage Below Normal The analog sensor supply voltage is below normal for one second. Note: The 262 diagnostic codes indicate a problem with the 5 V power supply on the J2 ECM connector. The 269 diagnostic codes indicate a problem with the 5 V power supply on the J1 ECM connector.System OperationThe Electronic Control Module (ECM) supplies a regulated voltage of 5.0 0.2 VDC to the following sensors:
Atmospheric pressure sensor
Engine oil pressure sensor
Fuel pressure sensor
Fuel rail pressure sensor
Turbocharger inlet pressure sensor
Intake manifold pressure sensorThe supply voltage for the sensors is routed from the ECM to terminal A of each sensor connector. The sensor return for the sensors is routed from the ECM to terminal B of each sensor connector. The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.Note: The sensors are not protected from overvoltage. A short from the supply line to the +Battery may damage the sensors. If any of the 3 diagnostic codes are active, it is possible that a sensor has been damaged. Repair the sensor supply and check for any active sensor diagnostic codes in order to determine if a sensor has failed.
Illustration 1 g01682858
Typical schematic
Illustration 2 g01310557
Location of ECM connectors
(1) J2 ECM connector
(2) J1 ECM connector
Illustration 3 g01717781
P1 ECM connector
(P1-2) 5 V Sensor supply
(P1-3) Analog sensor return
Illustration 4 g01684553
P2 ECM connector
(P2-17) Sensor return
(P2-72) 5 V Sensor supply
(P2-54) Sensor return
(P2-80) 5 V Sensor supply
Illustration 5 g01159881
Sensor connector
(A) 5 V sensor supply
(B) Sensor return
(C) Signal Test Step 1. INSPECT ELECTRICAL CONNECTORS AND WIRING
Turn the keyswitch to the OFF position.
Thoroughly inspect the J1/P1 ECM connector and the J2/P2 ECM connector. Inspect all of the connectors that are associated with the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connectors that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and wiring for abrasion and for pinch points from the sensors back to the ECM. Expected Result:All connectors, pins and sockets are completely coupled and/or inserted and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and connectors appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. CHECK FOR ACTIVE DIAGNOSTIC CODES
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Turn the keyswitch to the ON position.
Monitor the active diagnostic code screen on Cat ET. Check and record any active diagnostic codes. Look for the following diagnostic codes:
262-3
262-4
2131-3
2131-4 Note: Wait at least 30 seconds in order for the diagnostic codes to become active.Expected Result:No diagnostic codes are active.Results:
OK - No diagnostic code is active.Repair: The problem is no longer present. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - A 262-3, 262-4, 2131-3 or 2131-4 diagnostic code is active at this time. Proceed to Test Step 3.Test Step 3. DISCONNECT THE 5 VOLT SENSOR(S) WHILE YOU MONITOR THE ACTIVE DIAGNOSTIC CODES
Use this procedure for any 262 diagnostic codes.
Monitor the active diagnostic code screen on Cat ET while you disconnect each 5 Volt sensor at the sensor connector. Check for an active 262-3 code or an active 262-4 code. Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Disconnect the following sensors one at a time:
Fuel pressure sensor
Fuel rail pressure sensor
Engine oil pressure sensor
Atmospheric pressure sensor
Intake manifold pressure sensor
Use this procedure for any 2131 diagnostic codes.
Monitor the active diagnostic code screen on Cat ET while you disconnect each 5 Volt sensor at the sensor connector. Check for an active 2131-3 code or an active 2131-4 code. Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Disconnect the following sensors one at a time:
Turbocharger inlet pressure sensor
Turn the keyswitch to the OFF position. Expected Result:The diagnostic code deactivates when a particular sensor is disconnected.Results:
OK - The diagnostic code deactivates when a particular sensor is disconnected.Repair: Connect the suspect sensor. If the code returns, replace the sensor. Connect the connector(s). Verify that the problem is resolved.STOP
Not OK - The diagnostic code remains active after the sensor(s) is disconnected. Leave the sensor(s) disconnected. The sensor(s) is not the cause of the diagnostic code. Proceed to Test Step 4.Test Step 4. CHECK THE 5 VOLT SUPPLY VOLTAGES AT THE ECM


Parts insulation EVINRUDE:

0351127
 
0351127 *INSULATION, Sound - (DR & W Models)
E40DELSOR, E40DELSRC, E40DPLAAA, E40DPLABA, E40DPLSOR, E40DPLSRC, E40DRLAAA, E40DRLABA, E40DRLIIS, E40DRLINC, E40DRLISD, E40DRLISF, E40DRLSCB, E40DRLSDA, E40DRLSEE, E40DRLSOR, E40DRLSRC, E40DRLSUM, E40DTLAAA, E40DTLABA, E50DPLAAA, E50DPLABA, E50DPLSO
0350770
 
0350770 *INSULATION, Sound-Port
E40DELSOR, E40DELSRC, E40DPLSOR, E40DPLSRC, E40DRLSOR, E40DRLSRC, E50DPLSOR, E50DPLSRC, E60WDRLSOS
0350772
 
0350772 *INSULATION, Sound - Starboard
E40DELSOR, E40DELSRC, E40DPLSOR, E40DPLSRC, E40DRLSOR, E40DRLSRC, E50DPLSOR, E50DPLSRC, E60WDRLSOS
0351837
 
0351837 *INSULATION, Sound-Port
E40DELSDA, E40DPLAAA, E40DPLABA, E40DPLIIS, E40DPLINC, E40DPLISD, E40DPLISF, E40DPLSCB, E40DPLSDA, E40DPLSEE, E40DPLSUM, E40DRLAAA, E40DRLABA, E40DRLIIS, E40DRLINC, E40DRLISD, E40DRLISF, E40DRLSCB, E40DRLSDA, E40DRLSEE, E40DRLSUM, E40DTLAAA, E40DTLAB
0351838
 
0351838 *INSULATION, Sound - Starboard
E40DELSDA, E40DPLAAA, E40DPLABA, E40DPLIIS, E40DPLINC, E40DPLISD, E40DPLISF, E40DPLSCB, E40DPLSDA, E40DPLSEE, E40DPLSUM, E40DRLAAA, E40DRLABA, E40DRLIIS, E40DRLINC, E40DRLISD, E40DRLISF, E40DRLSCB, E40DRLSDA, E40DRLSEE, E40DRLSUM, E40DTLAAA, E40DTLAB
Back to top