0317657 LOCKOUT LEVER EVINRUDE
18304A, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25904R, 35602G, 40304D, 40404S, 40504C, 40604A, E25RCSA, E35ECSM, E40RSLR, E40RWCDB, E40RWCOM, E40RWCRA
LOCKOUT
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
- CYLINDER & CRANKCASE » 0317657
25402M, 25403M, 25452M, 25453M 1974
25502B, 25503B, 25552B, 25553B 1975
25602E, 25603E, 25652E, 25653E 1976
25702H, 25702S, 25703H, 25703S, 25752H, 25752S, 25753H, 25753S, 35702C, 35702H, 35703C, 35703H, 35752C, 35752H, 35753C, 35753H 1977
25802C, 25803C, 25852C, 25853C, 35802R, 35803R, 35852R, 35853R 1978
25904R, 25905R, 25952R, 25953R, 35902A, 35903A, 35952A, 35953A 1979
35602G, 35602S, 35603G, 35603S, 35652G, 35652S, 35653G, 35653S 1976
40304D, 40305D, 40354D, 40355D 1973
40404S, 40405S, 40454S, 40455S 1974
40504C, 40505C, 40554C, 40555C 1975
40604A, 40604R, 40605A, 40605R, 40654A, 40654R, 40655A, 40655R 1976
E25RCSA, E25RLCSA, E25TECSA, E25TELCSA 1980
E35ECSM, E35ELCSM, E35TCSM, E35TLESM 1980
E40RSLR, E40RSR, E40RWLCTR, E40RWLTR 1983
E40RWCDB, E40RWLCDB 1986
E40RWCOM, E40RWLCOM 1985
E40RWCRA, E40RWLCRA 1984
Information:
Illustration 1 g00481278
System Schematic For Alarm Module (ALM)
All the fault indicators of the remote annunciator flash and/or all the fault indicators of the control panel alarm module flash. The indicators flash once per two seconds (0.5 Hz).Note: The maximum number of modules (Alarm, Remote Annunciator, or Customer Interface Module), that can be connected to the GSC is three. (There is no limit on the number of Custom Alarm Modules that can be used in an application.) The maximum distance between a module and the GSC is 305 m (1000 ft). If these specifications are not met, the information on the data link can be erratic. Also, the indicators on the alarm module could flash. If the conditions are not in compliance with the specifications, reduce the number of modules and/or shorten the distance to the GSC.The data link will malfunction under the following conditions with multiple modules:
One of the modules is powered down. ("B+" or "B-" is disconnected.)
The module that is powered down remains connected to the data link.Under these conditions, the indicators that are controlled by the data link of the other modules that are powered up will flash at .5 Hz.
Check the data wire.
Turn the ECS to OFF/RESET.
Disconnect the harness connector from the GSC.
Check for an open. Measure the resistance from terminal 2 of the alarm module to contact 35 of the GSC harness connector. The resistance should be 5 ohms or less.
Check for a short. Measure the resistance from contact 35 of the GSC harness connector to the battery (B+) and ground (B−) at the relay module. The resistance should be greater than 5000 ohms. Expected Result: For 1c, the resistance should be 5 ohms or less. For 1d, the resistance should be greater than 5000 ohms.Results:
OK - All resistance measurements are correct. Proceed to next step.
Not OK - One or more of the resistance measurements are NOT correct. Therefore, the harness wiring with the incorrect resistance is faulty. Troubleshoot the faulty wiring and repair the faulty harness wiring. STOP.
Measure the voltage at the alarm module. The ECS remains in the OFF/RESET position.
Reconnect the harness connector to the GSC.
At the alarm module, measure the DC voltage from terminal 2 to terminal 7. The voltage will be changing. The voltage should be between 1 and 10 DCV. Note: If you are troubleshooting a remote annunciator, measure the DC voltage from contact 35 to contact 31 of the GSC harness connector. Make the measurement by using the 7X-1710 Multimeter Probe Group. Do not disconnect the harness from the GSC. This voltage measurement should agree with the preceding measurement of 2b. If the voltages do not agree, the wire is faulty. The wire is faulty from terminal 2 of the remote annunciator to the terminal in the internal panel.
Disconnect all wires from terminal 2 of the alarm module. Again measure the DC voltage from terminal 2 to terminal 7 at the alarm module. The voltage should be 10.5 1.0 DCV. Expected Result: For 2b, the voltage should be between 1 and 10 DCV. For 2c, the voltage should be 10.5 1.0 DCV.Results:
OK - Both voltage measurements are correct. Therefore, replace the alarm module. STOP.
Not OK - Both voltage measurements are low. Therefore, replace the alarm module.
Not OK - The first measurement is low and the second measurement is high. Therefore, replace the GSC. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOP.
Parts lockout EVINRUDE:
0317971
0317971 LOCKOUT LEVER, Exh. cover
40304D, 40404S, 40504C, 40604A, E40RSLR, E40RWCDB, E40RWCOM, E40RWCRA