0437712 EVINRUDE LEAF PLATE ASSEMBLY


0437712 LEAF PLATE ASSEMBLY EVINRUDE B25JREUR, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25BAECM, BE25BAEDR, BE25EECE, BE25EEDM, BE25EEUB, BE30BAECS, BE30BAEDE, BE30BAEEC, BE30BAEUD, BE30BASIA, BE30BASSR, BE30EECS, BE30EEDE, BE30EEUD, E20CREDA, E25JREDC, E25RED LEAF
0437712 LEAF PLATE ASSEMBLY EVINRUDE
Rating:
13

Buy LEAF PLATE ASSEMBLY 0437712 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 43771
 

BRP EVINRUDE entire parts catalog list:

B25JREUR, BE25BAEUA, BE25BALEUA, E25REUM, E25RLEUM, HE25RAEUM, SE25RDEUR 1997
BE20SEECB, BE20SELECB 1998
BE20SEEDA, BE20SELEDA 1996
BE20SEEUM, BE20SELEUM 1997
BE20SRECB, BE20SRLECB 1998
BE20SREDA, BE20SRLEDA 1996
BE20SREUM, BE20SRLEUM, E20CREUM, E20CRLEUM 1997
BE25BAECM, BE25BALECM, E25JRECA, E25RECB, E25RLECB, SE25RDECA 1998
BE25BAEDR, BE25BALEDR, BE25BREDC, BE25BRLEDC, HE25RAEDA, SE25RDEDC 1996
BE25EECE, BE25ELECE, E25EECE, E25ELECE 1998
BE25EEDM, BE25ELEDM, BE25EREDC, BE25ERLEDC, E25EEDM, E25ELEDM 1996
BE25EEUB, BE25ELEUB, E25EEUB, E25ELEUB 1997
BE30BAECS, BE30BALECS 1998
BE30BAEDE, BE30BALEDE 1996
BE30BAEEC, BE30BAEEN 1999
BE30BAEUD, BE30BALEUD, E30REUD, E30RLEUD 1997
BE30BASIA 2001
BE30BASSR 2000
BE30EECS, BE30ELECS, E30EECS, E30ELECS 1998
BE30EEDE, BE30ELEDE, E30EEDE, E30ELEDE 1996
BE30EEUD, BE30ELEUD, E30EEUD, E30ELEUD 1997
E20CREDA, E20CRLEDA, HE20CREDA, HE20CRLEDA 1996
E25JREDC 1996
E25REDA, E25RLEDA, HE25REDA, HE25RLEDA 1996
E25RWEDC, E25RWLEDC, HE25FPO, HE25RSLO 1996
E25RWEOS, E25RWLEOS 1995
E25RWEUR, E25RWLEUR, HE25FPV, HE25RSLV, SE25RPLV, SE25RPV 1997
E25TEECB, E25TELECB 1998
E25TEEDA, E25TELEDA, HE25TELEDA 1996
E25TEEUM, E25TELEUM 1997
E25WREEN, E25WREES, E25WRLEEN, E25WRLEES 1999
E25WRLSIR, E25WRSIR 2001
E25WRLSSC, E25WRSSC 2000
E28ESLEDR 1996
E28ESLEDR 1996
E30REDE, E30RLEDE, HE30REDE, HE30RLEDE 1996
E30TEECS, E30TELECB 1998
E30TEEDE, E30TELEDE 1996
E30TEEUD, E30TELEUD 1997
SE25RDEEM, SE25RDEEN 1999
SE25RDSIE 2001
SE25RDSSB 2000
SE25RPLP, SE25RPP 1998
SE35REDE, SE35RLEDE 1996

Information:


Table 1
Temperatures that are Necessary for Activation of the Air Inlet Heater Prior to Engine Cranking (30 Second Preheat Cycle)
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 25° C (77° F)
Greater than 1675 m (5500 ft) 53° C (127° F) If the sum of the temperatures is below the temperature that is mentioned in Table 1, the air inlet heater will be activated for a maximum of 30 seconds during the preheat cycle.If the operator attempts to start the engine prior to the completion of preheat, the ECM reverts to the mode of engine cranking.Mode of Engine CrankingDuring engine cranking, the ECM first checks if the coolant temperature is less than 0 °C (32 °F). If this condition is true, the ECM activates the heater during engine cranking.If the preceding condition is false, the ECM calculates the sum of the coolant temperature plus the intake manifold air temperature. This sum must be below the following temperature in order for the air inlet heater to be activated during engine cranking:
Table 2
Temperatures that are Necessary for Activation of the Air Inlet Heater During Engine Cranking
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 25° C (77° F)
Greater than 1675 m (5500 ft) 63° C (145° F) If either of the preceding conditions are true, the ECM will activate the heater until the engine starter is disengaged. If the engine fails to start, the ECM reverts to the mode of powerup and preheat. If the engine starts the ECM proceeds to the mode of engine started.Mode of Engine StartedAfter the engine has started, the same combination of intake manifold air temperature and coolant temperature will determine the state of the heater. The cycle has two strategies:
Continuous operation
Intermittent operationContinuous OperationDuring continuous operation of the air inlet heater, the heater may operate continuously for a maximum of seven minutes after the engine has started. The ECM will exit the mode of continuous operation early if the sum of the coolant temperature plus the intake manifold air temperature exceeds the following temperatures:
Table 3
Temperatures that are Necessary for an Early Exit from Continuous Operation of the Air Inlet Heater
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 35° C (95° F)
Greater than 1675 m (5500 ft) 63° C (145° F) When this temperature is exceeded the air inlet heater is turned off and the mode of engine started is completed.If the temperatures for the preceding strategy are not met in seven minutes, the strategy for intermittent operation will be performed.Intermittent OperationDuring the strategy for intermittent operation, the ECM cycles the power to the air inlet heater in ten second intervals.This strategy will be effective for a maximum of 13 minutes after the strategy has begun. The ECM will exit the mode of intermittent operation early if the sum of the coolant temperature plus the intake manifold air temperature exceeds the following temperatures:
Table 4
Temperatures that are Necessary for an Early Exit from Intermittent Operation of the Air Inlet Heater
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 35° C (95° F)
Greater than 1675 m (5500 ft) 63° C (145° F) When this temperature is exceeded, the ECM shuts off the air inlet heater until the keyswitch is cycled.If there is an active diagnostic code for the coolant temperature sensor or the intake manifold air temperature sensor, the following strategy will be used:Coolant Temperature SensorIf there is an active diagnostic code for the coolant temperature sensor, all temperature conditions will rely solely on the air inlet temperature sensor. All temperature conditions will be satisfied at an air inlet temperature of 10 °C (50 °F) at all altitudes.Air inlet Temperature SensorIf there is an active diagnostic code for the air inlet temperature sensor, all temperature conditions will rely solely on the coolant temperature sensor. All temperature conditions will be satisfied at a coolant temperature of 40 °C (104 °F) at all altitudes.
Illustration 1 g01351393
Schematic for the air inlet heater
Test Step 1. Inspect the Electrical Connectors and the Wiring
Turn the keyswitch to the OFF position.
Illustration 2 g01351533
Location of the components that are related to the air inlet heater (typical left side engine view)
(1) Air inlet heater relay
(2) Air inlet heater
(3) J2/P2 ECM connectors
Thoroughly inspect all of the connections for relay (1) and for heater element (2). Also, thoroughly inspect ECM connectors (3). Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 3 g01351538
(P2-9) Return for the air inlet heater
(P2-12) Air inlet heater


Parts leaf EVINRUDE:

0342054
LEAF VALVE
0342054 LEAF VALVE
B25JREUR, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25BAECM, BE25BAEDR, BE25EECE, BE25EEDM, BE25EEUB, BE30BAECS, BE30BAEDE, BE30BAEEC, BE30BAEUD, BE30BASIA, BE30BASSR, BE30EECS, BE30EEDE, BE30EEUD, E20CREDA, E25JREDC, E25RED
Back to top