0330276 EVINRUDE LOCKOUT LEVER, Slide


0330276 LOCKOUT LEVER, Slide EVINRUDE BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E105WELEEN, E105WELSIF, E105WELSSC, E105WRLEES, E105WRLSIF, E105WRLSSC, E40ECEC, E40EEIA, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB, E40JRECA, E40JREDC, E40JREOS, E40JREUR, E40WREES, E4 LOCKOUT
0330276 LOCKOUT LEVER, Slide EVINRUDE
Rating:
8

Buy LOCKOUT LEVER, Slide 0330276 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 34
 

BRP EVINRUDE entire parts catalog list:

BE40EECR, BE40ELECR, BE40TLECR, E40ELECR, E40RECR, E40RLECR, E40TEECR, E40TELECR, E40TLECR, E40TTLECR 1998
BE40EEDS, BE40ELEDS, BE40TLEDS, E40ELEDS, E40REDS, E40RLEDS, E40TEEDS, E40TELEDS, E40TLEDS, E40TTLEDS, HE40REDS, HE40RLEDS 1996
BE40EEUC, BE40ELEUC, BE40TLEUC, E40ELEUC, E40REUC, E40RLEUC, E40TEEUC, E40TELEUC, E40TLEUC, E40TTLEUC, HE40REUC, HE40RLEUC 1997
BE50BEEDS, BE50BELEDS, BE50TLEDS, E50JEDS, E50TLEDS, SE50TLEDS 1996
BE50ESECC, BE50RLECR, BE50TLECR, BE50TSLECC, E50ESLECC, E50TLECR, E50TSLECC 1998
BE50RLEUC, BE50TLEUC, BE50TSLEUS, E50ESLEUR, E50JEUC, E50TLEUC, E50TSLEUS 1997
E105WELEEN, E105WELEES, E105WPLEES, E105WPXEES 1999
E105WELSIF, E105WPLSIF, E105WPXSIF 2001
E105WELSSC, E105WPLSSC, E105WPXSSC 2000
E105WRLEES, E105WRYEES 1999
E105WRLSIF, E105WRYSIF 2001
E105WRLSSC, E105WRYSSC 2000
E40ECEC, E40ELCEC, E40RCEC, E40RLCEC, E40TECEC, E40TELCEC, E40TLCEC, E40TTLCEC, TE40ELCEC 1989
E40EEIA, E40ELEIA, E40REIA, E40RLEIA, E40TEEIA, E40TELEIA, E40TLEIA, E40TTLEIA, TE40ELEIA, VE40EEIA, VE40ELEIA, VE40TELEIA, VE40TLEIA 1991
E40EENJ, E40EENM, E40ELENJ, E40ELENM, E40RENM, E40RLENM, E40TEENJ, E40TEENM, E40TELENJ, E40TELENM, E40TLENJ, E40TLENM, E40TTLENM, TE40ELENJ, TE40ELENM, VE40EENJ, VE40EENM, VE40ELENJ, VE40ELENM, VE40TELENJ, VE40TELENM, VE40TLENJ, VE40TLENM 1992
E40EEOD, E40ELEOD, E40REOD, E40RLEOD, E40TEEOD, E40TELEOD, E40TLEOD, E40TTLEOD 1995
E40EERE, E40ELERE, E40RERE, E40RLERE, E40TEERE, E40TELERE, E40TLERE, E40TTLERE 1994
E40EESR, E40ELESR, E40RESR, E40RLESR, E40TEESR, E40TELESR, E40TLESR, E40TTLESR, TE40ELESR, TE40TELESF, TE40TELESR, VE40EESR, VE40ELESR, VE40TELESR, VE40TLESR 1990
E40EETB, E40ELETB, E40RETB, E40RLETB, E40TEETB, E40TELETB, E40TLETB, E40TLETF, E40TTLETB, E40TTLETF, TE40ELETB, VE40EETB, VE40ELETB, VE40TELETB, VE40TLETB, VE40TLETF 1993
E40JRECA 1998
E40JREDC 1996
E40JREOS 1995
E40JREUR 1997
E40WREES, E40WRLEES, E40WRYEES 1999
E40WRLSIR, E40WRSIR, E40WRYSIR 2001
E40WRLSSC, E40WRSSC, E40WRYSSC 2000
E45RCE, E45RCLE, E45WMLE 1989
E45RCEIA, E45RCLEIA, E45WMLEIA 1991
E45RCENM, E45RCLENM, E45WMLENM 1992
E45RCEOD, E45RCLEOD 1995
E45RCERE, E45RCLERE 1994
E45RCESR, E45RCLESR, E45WMLESR 1990
E45RCETB, E45RCLETB 1993
E45RCLEDS, HE45RCLEDS, SE45RSLH 1996
E45RCLEUC, HE45RCLEUC, SE45RSLB 1997
E50BECEC, E50BELCEC, E50TLCEC, TE50TLCEC, TE50TLESF 1989
E50BEEIA, E50BELEIA, E50JEIA, E50TELEIA, E50TLEIA, VE50BEEIA, VE50BELEIA, VE50TLEIA 1991
E50BEENJ, E50BEENM, E50BELENJ, E50BELENM, E50JENJ, E50JENM, E50TELENM, E50TLENJ, E50TLENM, VE50BEENJ, VE50BEENM, VE50BELENJ, VE50BELENM, VE50TELENM, VE50TLENJ, VE50TLENM 1992
E50BEEOD, E50BELEOD, E50JEOD, E50TELEOD, E50TLEOD 1995
E50BEERE, E50BELERE, E50JERE, E50TELERE, E50TLERE 1994
E50BEESR, E50BELESR, E50TELESR, E50TLESR, TE50TLESF, TE50TLESR, VE50BEESR, VE50BELESR, VE50TLESR 1990
E50BEETB, E50BELETB, E50JETB, E50TELETB, E50TLETB, E50TLETF, VE50BEETB, VE50BELETB, VE50TLETB, VE50TLETF 1993
E50TELCEC 1989
E55RSLC, HE55RSLC, SE55RSC, SE55RSLC, SE55RSYC 1997
E55RSLG 1995
E55RSLW, HE55RSLW, SE55RSLW, SE55RSW, SE55RSYW 1996
E55RWLE 1989
E55RWLEIA 1991
E55RWLENM 1992
E55RWLERE 1994
E55RWLESR 1990
E55RWLETB 1993
E55WREES, E55WRLEES, E55WRYEES 1999
E55WRLSIR, E55WRSIR, E55WRYSIR 2001
E55WRLSSC, E55WRSSC, E55WRYSSC 2000
E65RSLC 1995
E65RSLM, SE65RSLM, SE65RSYM 1996
E65RSLZ2, SE65RSLZ2, SE65RSYZ2 1997
E65RWLCDR, E65TELCDR 1986
E65RWLCOC, E65TELCOC 1985
E65RWLCRS, E65TELCRS, E65WTLCRS 1984
E65WRLEEO, E65WRLEES, E65WRYEEO, E65WRYEES 1999
E65WRLSIR, E65WRYSIR 2001
E65WRLSSC, E65WRYSSC 2000
SE105RWLH, SE105RWYH 1998
SE105RWLP, SE105RWYP 1997
SE105WELV, SE105WEXV, SE105WRPLV, SE105WRPXV 1998
SE125RWYJ 1997
SE125RWYN 1998
SE125RWYV 1996
SE40RPB, SE40RPLB, SE40RPYB 1997
SE40RPH, SE40RPLH, SE40RPYH 1996
SE40RPLT2, SE40RPT2, SE40RPYT2 1998
SE55RSLM2, SE55RSM2, SE55RSYM2 1998
SE65RSLD, SE65RSYD 1998

Information:


Table 1
Typical Voltage Of Electrical System During Cranking At Various Ambient Temperatures
Temperature 12 V System 24 V System
−23 to −7°C (−10 to 20°F) 6 to 8 V 12 to 16 V
−7 to 10°C (20 to 50°F) 7 to 9 V 14 to 18 V
10 to 27°C (50 to 80°F) 8 to 10 V 16 to 24 V Table 2 shows the maximum acceptable loss of voltage in the battery circuit. The battery circuit supplies high current to the starting motor. The values in the table are for engines which have service of 2000 hours or more.
Table 2
Maximum Acceptable Voltage Drop In The Starting Motor Circuit During Cranking
Circuit 12 V System 24 V System
Battery post "-" to the starting motor terminal "-" 0.7 V 1.4 V
Drop across the disconnect switch 0.5 V 1.0 V
Battery post "+" to the terminal of the starting motor solenoid "+" 0.5 V 1.0 V
Solenoid terminal "Bat" to the solenoid terminal "Mtr" 0.4 V 0.8 V Voltage drops that are greater than the amounts in table 2 are caused most often by the following conditions:
Loose connections
Corroded connections
Faulty switch contactsDiagnosis Procedure
The procedures for diagnosing the starting motor are intended to help the technician determine if a starting motor needs to be replaced or repaired. The procedures are not intended to cover all possible problems and conditions. The procedures serve only as a guide.
If equipped with electric start, do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.Never turn the disconnect switch off while the engine is running. Serious damage to the electrical system can result.
If the starting motor does not crank or cranks slow, perform the following procedure:
Measure the voltage of the battery. Measure the voltage across the battery posts with the multimeter when you are cranking the engine or attempting to crank the engine. Do not measure the voltage across the cable post clamps.
If the voltage is equal to or greater than the voltage in table 1, then go to step 2.
The battery voltage is less than the voltage in Table 1. A low charge in a battery can be caused by several conditions.
Deterioration of the battery
A shorted starting motor
A faulty alternator
Loose drive belts
Current leakage in another part of the electrical system
Measure the current that is sent to the starting motor solenoid from the positive post of the battery. Note: If the following conditions exist, do not perform the test in step 2 because the starting motor has a problem.
The voltage at the battery post is within 2 V of the lowest value in the applicable temperature range of table 1.
The large starting motor cables get hot.Use a suitable ammeter in order to measure the current. Place the jaws of the ammeter around the cable that is connected to the "bat" terminal. Refer to Specifications, "Starter Motor" for the maximum current that is allowed for no load conditions.The current and the voltages that are specified in Specifications are measured at a temperature of 27°C (80°F). When the temperature is below 27°C (80°F), the voltage will be lower through the starting motor. When the temperature is below 27°C (80°F), the current through the starting motor will be higher. If the current is too great, a problem exists in the starting motor. Repair the problem or replace the starting motor.If the current is within the specification, proceed to step 3.
Measure the voltage of the starting motor.
Use the multimeter in order to measure the voltage of the starting motor, when you are cranking or attempting to crank the engine.
If the voltage is equal to or greater than the voltage that is given in table 1, then the battery and the starting motor cable that goes to the starting motor are within specifications. Go to step 5.
The starting motor voltage is less than the voltage specified in table 1. The voltage drop between the battery and the starting motor is too great. Go to step 4.
Measure the voltage.
Measure the voltage drops in the cranking circuits with the multimeter. Compare the results with the voltage drops which are allowed in table 2.
Voltage drops are equal to the voltage drops that are given in table 2 or the voltage drops are less than the voltage drops that are given in Table 2. Go to step 5 in order to check the engine.
The voltage drops are greater than the voltage drops that are given in table 2. The faulty component should be repaired or replaced.
Rotate the crankshaft by hand in order to ensure that the crankshaft is not stuck. Check the oil viscosity and any external loads that could affect the engine rotation.
If the crankshaft is stuck or difficult to turn, repair the engine.
If the engine is not difficult to turn, go to step 6.
Attempt to crank the starting motor.
The starting motor cranks slowly. Remove the starting motor for repair or replacement.
The starting motor does not crank. Check for the blocked engagement of the pinion gear and flywheel ring gear.Note: Blocked engagement and open solenoid contacts will give the same electrical symptoms.


Parts lockout EVINRUDE:

0330277
 
0330277 LOCKOUT LEVER, Pully
E65RWLCDR, E65RWLCOC, E65RWLCRS
0437040
 
0437040 LOCKOUT LEVER ASSY.
BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E105WELEEN, E105WELSIF, E105WELSSC, E105WRLEES, E105WRLSIF, E105WRLSSC, E40EEOD, E40EERE, E40JRECA, E40JREDC, E40JREOS, E40JREUR, E40WREES, E40WRLSIR, E40WRLSSC, E45RCEOD, E45RCERE, E45RC
Back to top