5007892 LOWER COVER Assy, Port - Smoke EVINRUDE
E200DHLSEB, E200DHXSEA, E200HCXSEA, E200HSLSEA, E225DCXSEB, E225DHLSEB, E225DPLSEB, E225DPXSEB, E225HSLSEC, E250DCXSEB, E250DHLSEC, E250DPLSEB, E250DPXSEB, E250HGLSES, E250HSLSES, E300DCXSEC, E300DPXSEC
LOWER
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
- LOWER ENGINE COVER » 5007892
E200HCXSEA 2009
E200HSLSEA 2009
E225DCXSEB, E225DCZSEB 2009
E225DHLSEB, E225DHXSEM 2009
E225DPLSEB 2009
E225DPXSEB, E225DPZSEB 2009
E225HSLSEC 2009
E250DCXSEB, E250DCZSEB 2009
E250DHLSEC, E250DHXSEC 2009
E250DPLSEB 2009
E250DPXSEB, E250DPZSEB 2009
E250HGLSES, E250HGXSES 2009
E250HSLSES 2009
E300DCXSEC, E300DCZSEC 2009
E300DPXSEC, E300DPZSEC, E300DSLSES 2009
Information:
Starting The Engine
Woodward PSG Governor:
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted.2. Push the START-STOP switch to the START position.3. When the engine starts, release the START-STOP switch.On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and conditions.4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings.Woodward UG8 Governor:
Start the engine as follows: If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel. 1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES topic, Woodward UG8 Governor. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".
1-Droop knob. 2-Synchronizer knob. 3-Load limit knob. 4-Synchronizer Indicator. 5-Load pointer.4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8".5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizer knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached.When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached. 3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked "CHECK WITH ENGINE RUNNING".4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. (Do not confuse this with the "RAISE-LOWER" switch.)
ON-OFF-STOP SWITCHb. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit knob to "0". 5. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE PROCEDURES topic, Fuel Tank.6. Drain the raw water system if below freezing temperatures are expected.7. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART.
Woodward PSG Governor:
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted.2. Push the START-STOP switch to the START position.3. When the engine starts, release the START-STOP switch.On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and conditions.4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings.Woodward UG8 Governor:
Start the engine as follows: If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel. 1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES topic, Woodward UG8 Governor. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".
1-Droop knob. 2-Synchronizer knob. 3-Load limit knob. 4-Synchronizer Indicator. 5-Load pointer.4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8".5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizer knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached.When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached. 3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked "CHECK WITH ENGINE RUNNING".4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. (Do not confuse this with the "RAISE-LOWER" switch.)
ON-OFF-STOP SWITCHb. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit knob to "0". 5. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE PROCEDURES topic, Fuel Tank.6. Drain the raw water system if below freezing temperatures are expected.7. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART.
Parts lower EVINRUDE:
5005205
5005205 LOWER COVER Assy,, Port "WHITE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5005718
5005718 LOWER COVER Assy,, Port "BLUE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5005932
5005932 LOWER COVER Assy,, Port "BLUE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5005716
5005716 LOWER COVER Assy,, Port "WHITE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5005717
5005717 LOWER COVER Assy,, Starboard "WHITE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5005719
5005719 LOWER COVER Assy,, Starboard "BLUE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5005206
5005206 LOWER COVER Assy,, Starboard "WHITE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD
5006432
5006432 LOWER COVER Assy,, Starboard "BLUE"
DE200HXAAA, DE200HXAAC, DE200HXAAD, DE200XCAAA, DE200XCAAC, DE200XCAAD, DE225CXAAA, DE225CXAAC, DE225CXAAD, DE225CXINS, DE225PXAAA, DE225PXAAC, DE225PXAAD, DE225PXINS, DE250CXAAA, DE250CXAAC, DE250CXAAD, DE250CXISF, DE250PXAAA, DE250PXAAC, DE250PXAAD