0335660 EVINRUDE O-RING


0335660 O-RING EVINRUDE BE25ARECA, BE25AREDC, BE25AREUR, BE35ARECR, BE35AREDS, BE35AREEA, BE35AREUC, BE35ARSIB, BE35ARSSM, BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E40ECEC, E40EEIA, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB, E50BECEC, E50BEEIA, E50BE O
0335660 O-RING EVINRUDE
Rating:
63

Buy O-RING 0335660 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 33
 

BRP EVINRUDE entire parts catalog list:

BE25ARECA, BE25ARLECA, BE25KECA, BE25KLECA, BE25QLECA, E25KLECA, E25QLECA, E25RMECA, E25RMLECA, E25TKECA, E25TKLECA 1998
BE25AREDC, BE25ARLEDC, BE25KEDC, BE25KLEDC, BE25QLEDC, E25KLEDC, E25QLEDC, E25RMEDC, E25RMLEDC, E25TKEDC, E25TKLEDC 1996
BE25AREUR, BE25ARLEUR, BE25KEUR, BE25KLEUR, BE25QLEUR, E25KLEUR, E25QLEUR, E25RMEUR, E25RMLEUR, E25TKEUR, E25TKLEUR 1997
BE35ARECR, BE35ARLECR, BE35KECA, BE35KLECA, BE35QLECA, E35KLECA, E35QLECA, E35TKLECA 1998
BE35AREDS, BE35ARLEDS, BE35KEDC, BE35KLEDC, BE35QLEDC, E35KLEDC, E35QLEDC, E35RMLEDC, E35TKLEDC, HE35RMLEDC 1996
BE35AREEA, BE35KEEM 1999
BE35AREUC, BE35ARLEUC, BE35KEUR, BE35KLEUR, BE35QLEUR, E35KLEUR, E35QLEUR, E35RMLEUR, E35TKLEUR, HE35RMLEUR 1997
BE35ARSIB, BE35KSIE 2001
BE35ARSSM, BE35KSSB 2000
BE40EECR, BE40ELECR, BE40TLECR, E40ELECR, E40RECR, E40RLECR, E40TEECR, E40TELECR, E40TLECR, E40TTLECR 1998
BE40EEDS, BE40ELEDS, BE40TLEDS, E40ELEDS, E40REDS, E40RLEDS, E40TEEDS, E40TELEDS, E40TLEDS, E40TTLEDS, HE40REDS, HE40RLEDS 1996
BE40EEUC, BE40ELEUC, BE40TLEUC, E40ELEUC, E40REUC, E40RLEUC, E40TEEUC, E40TELEUC, E40TLEUC, E40TTLEUC, HE40REUC, HE40RLEUC 1997
BE50BEEDS, BE50BELEDS, BE50TLEDS, E50JEDS, E50TLEDS, SE50TLEDS 1996
BE50ESECC, BE50RLECR, BE50TLECR, BE50TSLECC, E50ESLECC, E50TLECR, E50TSLECC 1998
BE50RLEUC, BE50TLEUC, BE50TSLEUS, E50ESLEUR, E50JEUC, E50TLEUC, E50TSLEUS 1997
E40ECEC, E40ELCEC, E40RCEC, E40RLCEC, E40TECEC, E40TELCEC, E40TLCEC, E40TTLCEC, TE40ELCEC 1989
E40EEIA, E40ELEIA, E40REIA, E40RLEIA, E40TEEIA, E40TELEIA, E40TLEIA, E40TTLEIA, TE40ELEIA, VE40EEIA, VE40ELEIA, VE40TELEIA, VE40TLEIA 1991
E40EENJ, E40EENM, E40ELENJ, E40ELENM, E40RENM, E40RLENM, E40TEENJ, E40TEENM, E40TELENJ, E40TELENM, E40TLENJ, E40TLENM, E40TTLENM, TE40ELENJ, TE40ELENM, VE40EENJ, VE40EENM, VE40ELENJ, VE40ELENM, VE40TELENJ, VE40TELENM, VE40TLENJ, VE40TLENM 1992
E40EEOD, E40ELEOD, E40REOD, E40RLEOD, E40TEEOD, E40TELEOD, E40TLEOD, E40TTLEOD 1995
E40EERE, E40ELERE, E40RERE, E40RLERE, E40TEERE, E40TELERE, E40TLERE, E40TTLERE 1994
E40EESR, E40ELESR, E40RESR, E40RLESR, E40TEESR, E40TELESR, E40TLESR, E40TTLESR, TE40ELESR, TE40TELESF, TE40TELESR, VE40EESR, VE40ELESR, VE40TELESR, VE40TLESR 1990
E40EETB, E40ELETB, E40RETB, E40RLETB, E40TEETB, E40TELETB, E40TLETB, E40TLETF, E40TTLETB, E40TTLETF, TE40ELETB, VE40EETB, VE40ELETB, VE40TELETB, VE40TLETB, VE40TLETF 1993
E50BECEC, E50BELCEC, E50TLCEC, TE50TLCEC, TE50TLESF 1989
E50BEEIA, E50BELEIA, E50JEIA, E50TELEIA, E50TLEIA, VE50BEEIA, VE50BELEIA, VE50TLEIA 1991
E50BEENJ, E50BEENM, E50BELENJ, E50BELENM, E50JENJ, E50JENM, E50TELENM, E50TLENJ, E50TLENM, VE50BEENJ, VE50BEENM, VE50BELENJ, VE50BELENM, VE50TELENM, VE50TLENJ, VE50TLENM 1992
E50BEEOD, E50BELEOD, E50JEOD, E50TELEOD, E50TLEOD 1995
E50BEERE, E50BELERE, E50JERE, E50TELERE, E50TLERE 1994
E50BEESR, E50BELESR, E50TELESR, E50TLESR, TE50TLESF, TE50TLESR, VE50BEESR, VE50BELESR, VE50TLESR 1990
E50BEETB, E50BELETB, E50JETB, E50TELETB, E50TLETB, E50TLETF, VE50BEETB, VE50BELETB, VE50TLETB, VE50TLETF 1993
E50TELCEC 1989

Information:


Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service) , and either locked out or tagged DO NOT OPERATE.
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground. This connection is the first connection that is made at the installation. This connection is the last connection that should be removed. If the generator set is on flexible mounting pads, the ground connection must be flexible to avoid possible breakage in later operation.Ground connection cable or straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Joints that are silver soldered and bolted are preferred.Neutral Connections
The generators with a Wye Configuration usually have the neutral ground when the generator is installed. Grounding the neutral is for preventing damage to equipment.If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker. Also, the excessive current will cause the generator voltage to collapse. The result depends on the following items: electrical characteristics of the generator , type of fault and trip rating of the circuit breaker. An undervoltage device may be required to provide an adequate short circuit protection.There are some cases when the neutral wire is not grounded. An ungrounded generator neutral lead is acceptable when the possibility of grounds to the phase leads has been eliminated. An example of such measures is ground fault protective circuits. Ground fault protection requires the entire group of distribution circuits to be treated as a system. The owner should contact a certified consultant if a new distribution system is being developed. The owner should also contact a certified consultant if an existing system should be modified for the ground fault protection.Single Units
Each unit should be connected to a common ground.In a three-phase, four-wire system, the neutral wire should be grounded according to local wiring codes.Be sure to check your local wiring codes.Connection Diagrams
The generator lead connections are located in the terminal box on the generator or in the enclosure for the control panel.Change the position of the wire terminals to modify the connection. The code for the winding is specified on the nameplate.Wiring Code A for Three-Phase Configuration
Illustration 1 g00952030
Illustration 2 g00952058
Factory connection for "A" wiring code
Table 1
L-L Voltage for Wiring Code A
Winding 50 Hz 60 Hz
6 190-208 190-240
7 220-230 -
8 - 190-208 R 230 voltage sensing - 0 => (T8) / 110 V => (T11)R 438 LS voltage sensing - 0 => (T3) / 220 V => (T2)Wiring Code B for Single-Phase Configuration or Three-Phase Configuration
Illustration 3 g00952097
Illustration 4 g00952196
Factory connection for "B" wiring code


Parts o EVINRUDE:

0310327
O-RING,Gearcase head
0310327 O-RING,Gearcase head
1002R, 1802S, 1902C, 2102A, 2202M, 2302B, 2402E, 2502D, 2602S, 2702C, 2802R, 2902A, 3802A, 4006E, 4106D, 4206S, 4306C, 4406R, 4506A, 4606M, 4706B, 4806E, 4902B, 4904D, 5802B, BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E2RCIB, E2RC
0301877
"O" RING, Shift rod
0301877 "O" RING, Shift rod
10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 15404G, 15504C, 15604A, 18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 25904R, 33002M, 33802M, 33902A, 35602G, 40002A, 40
0317178
"O' RING
0317178 "O' RING
100193A, 100293R, 100990S, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 25702H, 25802C, 25904R, 35602G, 50202C, 50302R, 50442M, 50542B, 50902C,
0318372
"O" RING, Shift rod
0318372 "O" RING, Shift rod
100990S, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 50302R, 50442M, 50542B, 50902C, 55642E, 55772D, 55874S, 65372R, 70442M, 70572B, 70673D, 70773S, 70873C, 709
0321466
O-RING
0321466 O-RING
200640S, 50902C, 55642E, 55772D, 55874S, 70673D, 70773S, 70873C, 70973R, 75642D, BE40EEDS, BE50BEEDS, BE50DTLEDC, BE60ELEDR, BE70ELEDA, E35AELCDE, E35AELCUD, E40AELCCS, E40ECDE, E40ECEC, E40ECOB, E40ECRM, E40ECUD, E40EEIA, E40EENJ, E40EEOD, E40EERE,
0331188
O-RING, Cover
0331188 O-RING, Cover
BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE225CXECS, BE225CXEDE, BE225CXEUD, BE250CXECB, BE250CXEDA
0333572
O-RING
0333572 O-RING
BE40EEDS, BE4RDHEDS, BE50BEEDS, BE5DREDS, BE5DREUC, BE6DRECR, BE6DREDS, BE6DREUC, BE8REDS, C155WTLM, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLERC, E100STLESB, E100STLETS, E100WTLCUA, E100WTLEIB, E100WTLENE, E100WTLESM, E100WTLZ, E10ECCD
0334913
O-RING, Fuel connector
0334913 O-RING, Fuel connector
B25JREUR, BE10EEDD, BE10FAEDC, BE10FAEUR, BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE10RELEUS, BE15EEDS, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE15RELEUC, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25ARECA, BE25AREDC, BE25AREUR, BE25B
Back to top