5032369 EVINRUDE *O-RING


5032369 *O-RING EVINRUDE E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS O
5032369 *O-RING EVINRUDE
Rating:
28

Buy *O-RING 5032369 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
£7.18
 

18-09-2017

SBS Deutsc: SBS Deutschland GmbH
NK 5032369 Support Steering Link
Number on catalog scheme: 26
 

Compatible models:

BRP EVINRUDE entire parts catalog list:

E25EL4SIC, E25PL4SIC, E25R4SIC, E25RL4SIC, E25TE4SIC, E25TEL4SIC 2001
E25EL4SSS, E25PL4SSS, E25R4SSS, E25RL4SSS, E25TE4SSS, E25TEL4SSS 2000
E30EL4SIC, E30PL4SIC, E30R4SIC, E30RL4SIC, E30TE4SIC, E30TEL4SIC 2001
E30EL4SSS, E30PL4SSS, E30R4SSS, E30RL4SSS, E30TE4SSS, E30TEL4SSS 2000

Information:


Illustration 1 g01200467
Schematic for the Cat Data Link
Test Step 1. Inspect the Electrical Connectors and the Wiring
Turn the battery isolator switch to the OFF position.
Illustration 2 g01141049
Location of the J1/P1 ECM connectors (typical left side engine view)
Thoroughly inspect the J1/P1 ECM connectors. Also, thoroughly inspect the service tool connector. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".
Illustration 3 g01240936
P1 terminals that are associated with the Cat Data Link
(P1-8) Cat Data Link +
(P1-9) Cat Data Link −
Illustration 4 g01200543
Terminals at the service tool connector that are associated with the Cat Data Link
(D) Cat Data Link +
(E) Cat Data Link −
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the Cat Data Link.
Check the allen head screw on each ECM connector for the proper torque. Also, check the allen head screw on the customer connector for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values. Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The harness and the connectors appear to be OK. Proceed to Test Step 2.
Not OK - The connectors and/or the wiring are not OK.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the original problem is resolved.STOPTest Step 2. Check the Data Link for a Short Circuit
Disconnect the J1 connector.
Disconnect Cat ET from the service tool connector.
Measure the resistance between the points that are listed in Table 1. Be sure to wiggle the wires in the harnesses as you make each resistance measurement.
Table 1
Resistance Measurements for the Cat Data Link
Connector and Terminal Terminal
P1-8 (Cat Data Link +) All of the other terminals on the P1 connector
Ground stud
P1-9 (Cat Data Link -) All of the other terminals on the P1 connector
Ground stud Expected Result:Each check of the resistance indicates an open circuit.Results:
OK - Each check of the resistance indicates an open circuit. The data link is not shorted to another wire that is in the harness. Proceed to Test Step 3.
Not OK - At least one check of the resistance does not indicate an open circuit. There is a short circuit in the harness or in a connector.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Verify that the original problem is resolved.STOPTest Step 3. Check the Data Link for an Open Circuit
Fabricate a jumper wire that can be used to short two terminals at the service tool connector. Crimp connector pins to each end of the jumper wire. Use the jumper wire in order to create a short circuit between terminals D (Cat Data Link +) and E (Cat Data Link −) at the service tool connector.
Measure the resistance between P1-8 (Cat Data Link +) and P1-9 (Cat Data Link −) at the ECM connector. Expected Result:Resistance indicates that a short circuit condition exists.Results:
OK - Resistance indicates a short circuit.Repair: The data link does not have an open in the harness. Perform the following procedure:
Connect the J1/P1 connectors. Connect Cat ET to the service tool connector.
Use Cat ET to check that communications can be established over the Cat Data Link. If Cat ET is unable to communicate over the data link, there may be a problem with the ECM. Replace the ECM. Refer to the electronic troubleshooting procedure Troubleshooting, "Replacing the ECM".STOP
Not OK - At least one check of the resistance does not indicate that a short circuit condition exists. There is an open circuit or excessive resistance in the harness. There may be a problem with a connector.Repair: Repair the wiring and/or the connectors. Replace parts, if necessary. Verify that the original problem is resolved.STOP


Parts o EVINRUDE:

0334913
O-RING, Fuel connector
0334913 O-RING, Fuel connector
B25JREUR, BE10EEDD, BE10FAEDC, BE10FAEUR, BE10FDLECM, BE10FDLEDR, BE10FDLEUA, BE10RELEUS, BE15EEDS, BE15FAEDR, BE15FAEUA, BE15FDLECM, BE15RELEUC, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25ARECA, BE25AREDC, BE25AREUR, BE25B
5030541
 
5030541 O-RING, Cap
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS, E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E70, E70FLTLECS, E70PL4EEC, E70PL4SIA
5031173
 
5031173 O-RING, Sensor
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS, E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC, E70, E70PL4EEC, E70PL4SIA
5031260
O-RING, Shift rod
5031260 O-RING, Shift rod
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS, E40PL4EES, E40PL4SIR, E40PL4SSC, E50PL4EES, E50PL4EES, E50PL4SIR, E50PL4SIR, E50PL4SSC, E50PL4SSC
5032379
*O-RING
5032379 *O-RING
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS
5032389
*O-RING
5032389 *O-RING
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS
5031890
 
5031890 O-RING, Bearing housing
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS
5032367
 
5032367 *O-RING
E25EL4SIC, E25EL4SSS, E30EL4SIC, E30EL4SSS
Back to top