0984141 EVINRUDE OIL FILTER ASSY.


0984141 OIL FILTER ASSY. EVINRUDE BE200CXEDR, BE225CXEDE, CE275TLCDC, CE300TLCDC, E185ESERK, E185ESXENR, E185ESXESS, E185ESXETA, E185ESXW, E200CXARC, E200CXATF, E200CXCCR, E200CXCEA, E200CXEIB, E200CXENE, E200CXEOC, E200CXESM, E200STLCDR, E200STLCUA, E225CLCUB, E225CXARC, E225CXATF, OIL
0984141 OIL FILTER ASSY. EVINRUDE
Rating:
13

Buy OIL FILTER ASSY. 0984141 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$49.99
 

13-09-2017
1.00[0.45] pounds
OMC: OMC
0984141 New OEM OMC Evinrude Johnson Oil Filter Assembly
OMC||0984141
Number on catalog scheme: 4
 

BRP EVINRUDE entire parts catalog list:

BE200CXEDR, BE200TXEDR, E200CXEDR, E200STLEDM, E200TXEDR, LE200SLEDR 1996
BE225CXEDE, BE225PXEDE, BE225SLEDE, BE225TXEDE, E225CXEDE, E225CZEDE, E225PXEDE, E225STLEDE, E225TXEDE, E225TZEDE 1996
CE275TLCDC, CE275TXCDC, E275PTLCDC, E275PTXCDC 1986
CE300TLCDC, CE300TXCDC, E300TLCDC, E300TXCDC 1986
E185ESERK 1994
E185ESXENR 1992
E185ESXESS 1990
E185ESXETA, E185ESXETF 1993
E185ESXW 1989
E200CXARC, E200CXARK, E200CXERK, E200CXERS, E200CZARK, E200CZERK, E200CZERS, E200STLERK, E200STLERR, E200TXARC, E200TXARK, E200TXERK, E200TXERS, E200TZARK, E200TZERK, E200TZERS 1994
E200CXATF, E200CXATS, E200CXETD, E200CXETF, E200CZATF, E200CZATS, E200CZETD, E200CZETF, E200STLETC, E200STLETF, E200TXATF, E200TXATS, E200TXETD, E200TXETF, E200TZATF, E200TZATS, E200TZETD, E200TZETF, VE200SLETC, VE200SLETF, VE200TXETD, VE200TXETF, VE200TZETD, VE200TZETF 1993
E200CXCCR, E200STLCCM, E200TXCCR 1988
E200CXCEA, E200STLCEB, E200TXCEA, TE200TXCEA 1989
E200CXEIB, E200STLEID, E200TXEIB, VE200SLEID, VE200TXEIB 1991
E200CXENE, E200STLENS, E200TXENE, VE200SLENS, VE200TXENE 1992
E200CXEOC, E200CZEOC, E200STLEOA, E200TXEOC, E200TZEOC, LE200SLEOC 1995
E200CXESM, E200STLESE, E200TXESM, VE200SLESE, VE200TXESM 1990
E200STLCDR, E200TXCDS 1986
E200STLCUA, E200TXCUC 1987
E225CLCUB, E225CXCUB, E225PLCUB, E225PXCUB, E225TLCUB, E225TXCUB 1987
E225CXARC, E225CXARK, E225CXERK, E225CXERM, E225CZARK, E225CZERK, E225CZERM, E225PLERK, E225PLERM, E225PXARC, E225PXARK, E225PXERK, E225PXERM, E225PZARK, E225PZERK, E225PZERM, E225STLERC, E225STLERK, E225TLERK, E225TLERM, E225TXARC, E225TXARK, E225TXERK, E225TXERM, E225TZARK, E225TZERK, E225TZERM 1994
E225CXATF, E225CXATS, E225CXETA, E225CXETF, E225CZATF, E225CZATS, E225CZETA, E225CZETF, E225PLETA, E225PLETF, E225PXATF, E225PXATS, E225PXETA, E225PXETF, E225PZATF, E225PZATS, E225PZETA, E225PZETF, E225STLETF, E225TLETA, E225TLETF, E225TXATF, E225TXATS, E225TXETA, E225TXETF, E225TZATF, E225TZATS, E225TZETA, E225TZETF, VE225PLETA, VE225PLETF, VE225PXETA, VE225PXETF, VE225PZETA, VE225PZETF, VE225STLETF, VE225TLETA, VE225TLETF, VE225TXETA, VE225TXETF, VE225TZETA, VE225TZETF 1993
E225CXCCE, E225PLCCE, E225PXCCE, E225TLCCE, E225TXCCE 1988
E225CXCED, E225PLCED, E225PXCED, E225TLCED, E225TXCED 1989
E225CXEIC, E225PLEIC, E225PXEIC, E225TLEIC, E225TXEIC, VE225PLEIC, VE225PXEIC, VE225TLEIC, VE225TXEIC 1991
E225CXENR, E225PLENR, E225PXENR, E225TLENR, E225TXENR, VE225PLENR, VE225PXENR, VE225TLENR, VE225TXENR 1992
E225CXEOB, E225CZEOB, E225PXEOB, E225PZEOB, E225STLEOB, E225TXEOB, E225TZEOB 1995
E225CXESS, E225PLESS, E225PXESS, E225TLESS, E225TXESS, VE225PLESS, VE225PXESS, VE225TLESS, VE225TXESS 1990
E225PTLCDA, E225PTXCDA, E225TLCDA, E225TXCDA 1986
E250CXARC, E250CXERC, E250CZERC, E250TXARC, E250TXERC, E250TZERC 1994
E250CXATF, E250CXATS, E250CXETF, E250CXETS, E250CZATF, E250CZATS, E250CZETF, E250CZETS, E250TXATF, E250TXATS, E250TXETF, E250TXETS, E250TZATF, E250TZATS, E250TZETF, E250TZETS 1993
E250CXEIE, E250TXEIE 1991
E250CXEND, E250CZEND, E250TXEND, E250TZEND 1992
E250CXEOR, E250CZEOR, E250TXEOR, E250TZEOR 1995
E275CLCUR, E275CXCUR, E275PLCUR, E275PXCUR 1987
E275CXCCA, E275PLCCA, E275PXCCA 1988
E300CLCUR, E300CXCUR, E300PLCUR, E300PXCUR 1987
E300CXCCA, E300PLCCA, E300PXCCA 1988
E300CXCEM, E300PLCEM, E300PXCEM 1989
E300CXEIE, E300PLEIE, E300PXEIE 1991
E300CXEND, E300PLEND, E300PXEND 1992
E300CXEOR, E300PLEOR, E300PXEOR 1995
E300CXERC, E300PLERC, E300PXERC 1994
E300CXESB, E300PLESB, E300PXESB 1990
E300CXETF, E300CXETS, E300PLETF, E300PLETS, E300PXETF, E300PXETS 1993

Information:


The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Required Tools
300-8648 Insulation Testing Gp
349-4206 Insulation Testing Gp Periodically, use an insulation tester to check the insulation resistance of the generators main stator winding. The frequency of this test is determined by the generators environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for A Periodic Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Isolate the stator windings of the generator by disconnecting all other leads and cables from the generator terminals. Isolate the connections to the voltage regulator, the control panel, the switch gear, or other devices.
Connect the insulation testers RED lead to ground.
Connect the insulation testers BLACK lead to the Wye point or star point of the generators windings.
For units that are 600 V or less, set the voltage to 500 V. For units that are more than 600 V, set the voltage to 1000 V.
Use the 30/60 Time Resistance Method:
Apply voltage.
Observe the readings at 30 seconds. Observe the readings at 60 seconds.
Record the 60 second reading. This reading must be corrected for temperature.
Record temperature.
Record humidity.
Remove voltage.
Evaluate the readings. The actual value of the resistance may vary greatly between generators. For this reason, the insulations condition must be evaluated. Base this evaluation on the comparison between the 60 second resistance readings and the readings that were taken on previous dates. These two readings must be taken under similar conditions. If a 60 second resistance reading has a 50 percent reduction from the previous reading, the insulation may have absorbed too much moisture. Switch the insulation tester to the "OFF" position. Switch the insulation tester to the "OFF" position will discharge the insulation testers leads. Disconnect the insulation testers leads.Note: The results from the insulation resistance checks indicate when cleaning and/or repairing is becoming critical. Generally, insulation resistance will vary greatly with temperature. Therefore, always test at the same temperature and humidity. Refer to Illustration 1.Serial Number (Engine)____________________Serial Number (Generator)____________________
Illustration 1 g00633226


Parts oil EVINRUDE:

0321453
OIL RET.,Driveshaft
0321453 OIL RET.,Driveshaft
100990S, 115693D, 115790S, 115793S, 115890C, 135643D, 150840S, 150940C, 175740S, 200640S, 25702H, 25802C, 25904R, 35602G, 85693D, B25JREUR, BE20SEECB, BE20SEEDA, BE20SEEUM, BE20SRECB, BE20SREDA, BE20SREUM, BE25ARECA, BE25AREDC, BE25AREUR, BE25BAECM,
0387397
OIL LINE ASSY.,Lower
0387397 OIL LINE ASSY.,Lower
100990S, 115790S, 115890C, 150840S, 150940C, 175740S, 200640S, BE250CXECB, BE250CXEDA, BE250CXEUM, C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100MLCSC, E100STLCCA, E100STLCEM, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA
0390443
 
0390443 OIL LINE ASSY.,Upper
C155WTLM, E100MLCSC, E100STLCCA, E100STLCEM, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLEDR, E100WTLEIB, E100WTLENE, E100WTLEOC, E100WTLERS, E100WTLESM, E100WTLETD, E100WTLEUA, E100WTLZ, E110MLCCA, E110MLCDC, E110MLCEM, E110ML
0984142
 
0984142 OIL FILTER ASSY.
BE200CXEDR, BE225CXEDE, CE275TLCDC, CE300TLCDC, E185ESERK, E185ESXENR, E185ESXESS, E185ESXETA, E185ESXW, E200CXARC, E200CXATF, E200CXCCR, E200CXCEA, E200CXEIB, E200CXENE, E200CXEOC, E200CXESM, E200STLCDR, E200STLCUA, E225CLCUB, E225CXARC, E225CXATF,
0174638
 
0174638 OIL TANK KIT, (3.0 gallon)
E250CXEIE, E275CXCCA, E300CXCCA, E300CXCEM, E300CXEIE, E300CXESB
0175097
 
0175097 OIL PICKUP ASSEMBLY
E100STLEIE, E100STLEND, E100STLESB, E100WTLEIB, E100WTLENE, E115JLEIE, E115JLEND, E115MLESB, E120TLEIE, E120TLEND, E125ESXENR, E125ESXESS, E140CXEIA, E140CXENM, E150CXEIE, E150CXESB, E150ELEIS, E150ELENC, E150STLEIE, E155WTLEIB, E155WTLENE, E175EXEIS
0175000
 
0175000 OIL TANK KIT
E100STLEIE, E100STLEND, E100STLESB, E100WTLEIB, E100WTLENE, E115JLEIE, E115JLEND, E115MLESB, E120TLEIE, E120TLEND, E125ESXENR, E125ESXESS, E140CXEIA, E140CXENM, E150CXEIE, E150CXESB, E150ELEIS, E150ELENC, E150STLEIE, E155WTLEIB, E155WTLENE, E175EXEIS
0175095
 
0175095 OIL PICKUP ASSY.
E250CXEND, E300CXEND
Back to top