0206433 EVINRUDE OWNER'S MANUEL


0206433 OWNER'S MANUEL EVINRUDE 6002B OWNER
0206433 OWNER'S MANUEL EVINRUDE
Rating:
8

Buy OWNER'S MANUEL 0206433 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 20643
 

Compatible models:

6002B   EVINRUDE

BRP EVINRUDE entire parts catalog list:

6002B, 6003B 1970

Information:


Table 1
Required Tools    
Tool     Part Number     Part Description     Qty    
A     298-5564     T40 Torx Socket     1    
B     268-1968     Pry Bar     1    
C     370-8376     Plugs and Caps     1    Start By:
Remove the rocker shaft assembly.
Remove the fuel injection lines.
Contact with high pressure fuel may cause fluid penetration and burn hazards. High pressure fuel spray may cause a fire hazard. Failure to follow these inspection, maintenance and service instructions may cause personal injury or death.
Ensure that all adjustments and repairs that are carried out to the fuel system are performed by authorised personnel that have the correct training.Before begining ANY work on the fuel system, refer to Operation and Maintenance Manual, "General Hazard Information and High Pressure Fuel Lines" for safety information.Refer to Systems Operation, Testing and Adjusting Manual, "Cleanliness of Fuel System Components" for detailed information on the standards of cleanliness that must be observed during ALL work on the fuel system.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Use a deep socket in order to remove the electrical connections from the electronic unit injectors. Use of incorrect tooling will result in damage to the electronic unit injectors.
Turn the fuel supply to the OFF position.
Turn the battery disconnect switch to the OFF position.
Illustration 1 g01971774
Place a suitable container below tube assembly (1) in order to catch any fuel that might be spilled.
Loosen the nut on hose assembly (3) in order to allow the fuel to drain from tube assembly (1) .
Remove hose assembly (3) from tube assembly (1). Remove O-ring seal (2) .
Use Tooling (C) in order to cap the hose assembly immediately. Use Tooling (C) in order to plug the tube assembly immediately.
Illustration 2 g01971773
Make a temporary mark on valve bridges (5) in order to show the location and orientation. Remove valve bridges (5) .Note: Identification will ensure that the valve bridges can be reinstalled in the original location and the original orientation.
Remove seal (4) from the cylinder head and electronic unit injector (8) .
Make a temporary mark on wiring harness assembly (6) in order to show the location and orientation.
Use a deep socket to remove connections (7) from electronic unit injector (8) .
Use Tooling (A) in order to remove Torx screw (9) from clamp (10). Discard the Torx screw.Note: Tooling (A) must be used to ensure no damage to the electronic unit injector.
Illustration 3 g01971775
Illustration 4 g01972153
Make a temporary mark on electronic unit injector (8) in order to show the original location of the electronic unit injector.
Temporarily remove Tooling (C) from the electronic unit injector.
Use Tooling (B) to pry beneath clamp (10) and free electronic unit injector (8) from the cylinder head.Note: Always handle electronic unit injectors with care.
Immediately replace Tooling (C) onto the electronic unit injector.
If electronic unit injector (8) is to be reused, Follow Step 17 through Step 19 in order to remove sealing washer (12) and O-ring seal (11) .
Use a suitable tool in order to remove sealing washer (12) from electronic unit injector (8). Ensure that the sealing washer is removed from the cylinder head.Note: Ensure that the nozzle for the electronic unit injector is not damaged in any way on removal of the sealing washer.
Install Tooling (C) to the nozzle for electronic unit injector (8) and the open port of the electronic unit injector.
Remove O-ring seal (11) from electronic unit injector (8) .
If necessary, repeat Step 7 through Step 19 in order to remove the remaining electronic unit injector.
Illustration 5 g02311716
If