System Schematic For Run Relay (RR)The contacts for the run relay (RR) are available for use by the customer. The RR is located within the relay module. The GSC activates the run relay (RR) during engine cranking and running.Note: Whenever the GSC activates the RR, "K5" is shown on the lower display. "K5" is also shown on the lower display when the GSC attempts to activate the crank terminate relay. When the RR is not activated, "K5" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the RR.The following response is the system response to this fault while the RR is activated:
If a CID 445 occurs, then any equipment that is connected to RM-24 is deactivated. Also, any equipment that is connected to RM-23 is activated.The following response is the system response to this fault while the RR is not activated:
If a CID 445 occurs, then any equipment that is connected to RM-24 is not activated. Also, any equipment that is connected to RM-23 remains activated.The GSC treats this diagnostic code as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 445 FMI 12 is showing.
If this diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 445 FMI 12 is showing as a active fault or an inactive fault. Results:
No - A CID 445 FMI 12 has not occurred (NOT active and NOT inactive). STOP.
Yes - A CID 445 FMI 12 is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC housing. See Testing And Adjusting, "Relay Module Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK - Reassemble the relay module to the GSC. Proceed to 3.
NOT OK - Replace the connector clamp if it is missing. If the cable is damaged, replace the GSC. STOP.
Perform a functional check for the RR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-24 of the relay module. Remove the fuse "F4" from the relay module.
At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be greater than 5000 ohms.
Turn the ECS to the START position. Make sure that "K5" is showing on the lower display.
At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be less than 5 ohms.Expected Result: For 3.c, the resistance should be greater than 5000 ohms. For 3.e, the resistance should be less than 5 ohms.Results:
OK - It is likely that a temporary bad electrical connection existed and this troubleshooting procedure corrected it. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK - Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts plate EVINRUDE:

0303862
PLATE,Exhaust housing
0303862 PLATE,Exhaust housing
100882B, 18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25902B, 25904R, 33002M, 33802M, 33902A, 35602G, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 65832B, 85852A, E20CRCOS,
0307561
PLATE,Swivel
0307561 PLATE,Swivel
1002R, 10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 15404G, 15504C, 15604A, 18002C, 1802S, 18102S, 18202R, 18304A, 18802A, 18902B, 1902C, 2102A, 2202M, 2302B, 2402E, 25002C, 2502D, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25802C, 25
0303844
 
0303844 PLATE, Co-pilot
18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25702H, 25902B, 35602G
0310938
 
0310938 .PLATE, Swivel
33002M, 33802M, 33902A, 40002A, 40052A, 40072A, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 40802A, 40852A, 40872A, 40902R, 40952R, 40972R, E50BECIC, E55RCIM, E55RWLCOS, E55RWLCRD, E60ECIA
0314685
 
0314685 PLATE, Silencer cover
18002C, 18102S, 18202R, 18304A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25902B
0318409
0319212
 
0319212 PLATE
40304D, 40404S, 40504C, 40604A, 50302R
Back to top