0279705 EVINRUDE REMOTE CONTROL ASSY.


0279705 REMOTE CONTROL ASSY. EVINRUDE 115493B, 135443B, 50442M, 70442M, 85493B REMOTE
0279705 REMOTE CONTROL ASSY. EVINRUDE
Rating:
98

Buy REMOTE CONTROL ASSY. 0279705 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$219.99
 

13-09-2023

-: -
The ROP Shop | Side Mount Remote Control for Evinrude, Johnson, OMC, BRP 0279705, 0389724 Motor
The ROP Shop replacement Side Mount Remote Control for Evinrude, Johnson, OMC, BRP 0279705, 0389724 Motor || Specs - Connector Type: 6 Pin. Mounting Side: Port or Starboard. Refer to images 2 & 3 for more information || Includes - (1) Side Mount Remote Control, (1) Wiring Harness with 6 Pin Connector, (1) Push-to-Prime Ignition Key Switch, (1) Fast Idle Warm-up Lever, (1) Lanyard Stop Switch, (1) Mounting Platform, Mounting Hardware & Installation Manual; comes as shown in the first image || Fits/For Evinrude 1996 and newer Outboards; Evinrude 1973-1995 motors with the purchase of wiring harness adapter part number 0768411. This remote control assembly is NOT for use with Stern Drive applications || Pre 1979 engines require replacing the control cables with post 1979 control cables CC205XX. Please Note: The ROP Shop does not sell these control cables or harness adapter.
Number on catalog scheme: 27970
 

Compatible models:

BRP EVINRUDE entire parts catalog list:

115493B 1974
135443B, 135483B, 135489B 1974
50442M, 50443M, 50472M, 50473M 1974
70442M, 70443M, 70472M, 70473M 1974
85493B 1974

Information:

data-element=".content_table_54321">
Table 1
Service Table - Record Of Setpoint Values    
Generator Description: Site, Serial No., EMCP II+ Part Number., etc..    
Engine /Generator Programming OP5-0    
Setpoint    Specified Value    Actual Value (1)    Setpoint Description    Possible Values    Default Value    
P001             Fuel Solenoid Type     0 = ETR, 1 = ETS     0    
P002             Units Shown     0 = Eng, 1 = metric     0    
P003             Shutdown Override For Engine Fault     0 = shutdown,
1 = alarm     0    
P004             Shutdown Enable For Sensor Fault     0 = alarm,
1 = shutdown     0    
P005             Coolant Loss Sensor Installed     0 = w/o sensor,
1 = w/sensor     0    
P006             Shutdown Override For Coolant Loss Fault     0 = shutdown,
1 = alarm     0    
P007             System Voltage     24 volts or 32 volts     24    
P008             This Setpoint Is Not Used.     NA     NA    
P009             Number Of Ring Gear Teeth     95 to 350 teeth     136 teeth    
P010             Engine Overspeed     500 to 4330 rpm     2120 rpm    
P011             Crank Terminate Speed     100 to 1000 rpm     400 rpm    
P012             Oil Step Speed     400 to 1800 rpm     1350 rpm    
P013             Low Oil Pressure Shutdown At Rated Speed    
34 to 420 kPa (5 to 61 psi)    
205 kPa (30 psi)    
P014             Low Oil Pressure Shutdown At Idle Speed    
20 to 336 kPa (3 to 49 psi)    
70 kPa (10 psi)    
P015             High Water Temperature Shutdown    
85 to 123°C (185 to 253°F)    
107°C (225°F)    
P016             Low Water Temperature Alarm    
0 to 36°C (32 to 97°F)    
21°C (70°F)    
P017             Total Cycle Crank Time     5 to 360 seconds     90 seconds    
P018             Cycle Crank Time     5 to 300 seconds     10 seconds    
P019             Cooldown Time     0 to 30 minutes     5 minutes    
P020             AC Voltage     150V to 30.0 kV     700V    
P021             AC Current Full Scale     75A to 4000A     600A    
P022             GSC+ Engine Number     01 to 08     01    
P023             Engine Type     0 = MUI, 1 = gas,
2 = EUI     0    
P024             Crank Time Delay     0 to 20 seconds     5 seconds    
P025             Oil Temperature Sensor Installed     0 = w/o sensor,
1 = w/sensor     0    
P026             High Oil Temperature Shutdown    
85 to 123°C (185 to 253°F)    
107°C (225°F)    
P027             Shutdown Override For High Oil Temperature     0 = alarm,
1 = shutdown     0    
P028             Nameplate Voltage     100 to 25kV     480V    
P029             Nameplate Current     0 to 4000A     600A    
P030             Nameplate Power     0 to 10MW     400kW    
P031             Rated Frequency     50, 60 or 400 Hz     60    
P032             Connection Configuration Of Generator     0 = wye, 1 = delta     0    
P033            