0332494 SCREEN EVINRUDE
BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E40ECEC, E40EEIA, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB, E48ESLCER, E48ESLCER, E48ESLEDC, E48ESLEDC, E48ESLEIM, E48ESLEIM, E48ESLENB, E48ESLENB, E48ESLEOS, E48ESLEOS, E48ESLERD, E48
SCREEN
Price: query
Rating:
Compatible models:
BE40EECR
BE40EEDS
BE40EEUC
BE50BEEDS
BE50ESECC
BE50RLEUC
E40ECEC
E40EEIA
E40EENJ
E40EEOD
E40EERE
E40EESR
E40EETB
E48ESLCER
E48ESLEDC
E48ESLEIM
E48ESLENB
E48ESLEOS
E48ESLERD
E48ESLESA
E48ESLETE
E50BECEC
E50BEEIA
E50BEENJ
E50BEEOD
E50BEERE
E50BEESR
E50BEETB
E50TELCEC
SE40RSLD
SE40RSLR
SE40RSLZ
VE48ESLCER
VE48ESLENB
VE48ESLETE
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- GEARCASE » 0332494
BE40EEUC, BE40ELEUC, BE40TLEUC, E40ELEUC, E40REUC, E40RLEUC, E40TEEUC, E40TELEUC, E40TLEUC, E40TTLEUC, HE40REUC, HE40RLEUC 1997
BE50BEEDS, BE50BELEDS, BE50TLEDS, E50JEDS, E50TLEDS, SE50TLEDS 1996
BE50ESECC, BE50RLECR, BE50TLECR, BE50TSLECC, E50ESLECC, E50TLECR, E50TSLECC 1998
BE50RLEUC, BE50TLEUC, BE50TSLEUS, E50ESLEUR, E50JEUC, E50TLEUC, E50TSLEUS 1997
E40ECEC, E40ELCEC, E40RCEC, E40RLCEC, E40TECEC, E40TELCEC, E40TLCEC, E40TTLCEC, TE40ELCEC 1989
E40EEIA, E40ELEIA, E40REIA, E40RLEIA, E40TEEIA, E40TELEIA, E40TLEIA, E40TTLEIA, TE40ELEIA, VE40EEIA, VE40ELEIA, VE40TELEIA, VE40TLEIA 1991
E40EENJ, E40EENM, E40ELENJ, E40ELENM, E40RENM, E40RLENM, E40TEENJ, E40TEENM, E40TELENJ, E40TELENM, E40TLENJ, E40TLENM, E40TTLENM, TE40ELENJ, TE40ELENM, VE40EENJ, VE40EENM, VE40ELENJ, VE40ELENM, VE40TELENJ, VE40TELENM, VE40TLENJ, VE40TLENM 1992
E40EEOD, E40ELEOD, E40REOD, E40RLEOD, E40TEEOD, E40TELEOD, E40TLEOD, E40TTLEOD 1995
E40EERE, E40ELERE, E40RERE, E40RLERE, E40TEERE, E40TELERE, E40TLERE, E40TTLERE 1994
E40EESR, E40ELESR, E40RESR, E40RLESR, E40TEESR, E40TELESR, E40TLESR, E40TTLESR, TE40ELESR, TE40TELESF, TE40TELESR, VE40EESR, VE40ELESR, VE40TELESR, VE40TLESR 1990
E40EETB, E40ELETB, E40RETB, E40RLETB, E40TEETB, E40TELETB, E40TLETB, E40TLETF, E40TTLETB, E40TTLETF, TE40ELETB, VE40EETB, VE40ELETB, VE40TELETB, VE40TLETB, VE40TLETF 1993
E48ESLCER 1989
E48ESLCER 1989
E48ESLEDC 1996
E48ESLEDC 1996
E48ESLEIM 1991
E48ESLEIM 1991
E48ESLENB, E50RNLIB 1992
E48ESLENB 1992
E48ESLEOS 1995
E48ESLEOS 1995
E48ESLERD 1994
E48ESLERD 1994
E48ESLESA, VE48ESLESA 1990
E48ESLESA, E50RNLIA 1990
E48ESLETE, TE48ESLETE 1993
E48ESLETE, TE48ESLETE 1993
E50BECEC, E50BELCEC, E50TLCEC, TE50TLCEC, TE50TLESF 1989
E50BEEIA, E50BELEIA, E50JEIA, E50TELEIA, E50TLEIA, VE50BEEIA, VE50BELEIA, VE50TLEIA 1991
E50BEENJ, E50BEENM, E50BELENJ, E50BELENM, E50JENJ, E50JENM, E50TELENM, E50TLENJ, E50TLENM, VE50BEENJ, VE50BEENM, VE50BELENJ, VE50BELENM, VE50TELENM, VE50TLENJ, VE50TLENM 1992
E50BEEOD, E50BELEOD, E50JEOD, E50TELEOD, E50TLEOD 1995
E50BEERE, E50BELERE, E50JERE, E50TELERE, E50TLERE 1994
E50BEESR, E50BELESR, E50TELESR, E50TLESR, TE50TLESF, TE50TLESR, VE50BEESR, VE50BELESR, VE50TLESR 1990
E50BEETB, E50BELETB, E50JETB, E50TELETB, E50TLETB, E50TLETF, VE50BEETB, VE50BELETB, VE50TLETB, VE50TLETF 1993
E50TELCEC 1989
SE40RSLD 1997
SE40RSLR 1998
SE40RSLZ 1996
VE48ESLCER 1989
VE48ESLENB 1992
VE48ESLETE 1993
Information:
Note: Because the accumulator operates with a low pressure, a low-pressure gauge is needed for this procedure.Periodic measuring of the accumulator pressure can help detect wear of the accumulator seals.If oil leaks past the piston O-ring seal into the lower portion of the accumulator, the pressure in the lower portion will increase.If nitrogen gas leaks past the piston O-ring seal into the upper portion of the accumulator, the pressure in the upper portion will decrease. Low pressure can also be caused by nitrogen gas that leaks from the seals for the gas valve and/or for the end caps.Checking the Pressure
Note: The Tool Operating Manual, NEHS0742 is provided with the tool.
Illustration 1 g00995703
Assemble the following parts according to Tool Operating Manual, NEHS0742: nipple (1), needle valve (2), pipe tee (3), coupling (4), low-pressure gauge (5), chuck (6) and hose (7). Make sure that needle valve (2) is closed.
Illustration 2 g06316146
(8) Gas valve for the accumulator
Remove the guard and the cap to access the gas valve.
Connect chuck (6) to the gas valve. Turn the chuck handle to open the gas valve.
Wait until the low-pressure gauge stabilizes. Read the gauge.For the correct pressure, refer to the engine Specifications manual.If the pressure is correct, proceed to Step 5.If the pressure is too low, proceed to "Charging the Accumulator".
Turn the chuck handle to close the gas valve. Open needle valve (2) to purge the nitrogen gas from the tooling.
Remove the tooling from the gas valve. Install the cap and the guard over the gas valve.Charging the Accumulator
Note: Only use dry nitrogen gas to fill the accumulator.
Illustration 3 g00995724
Assemble the following parts according to Tool Operating Manual, NEHS0742: hose (1), nipple (2), coupling (3), regulator (4), and coupling (5). Connect coupling (5) to the nipple that is on the needle valve.
Crack the nitrogen bottle valve to purge any debris from the valve.
Make sure that regulator (4) is closed. Make sure that the nitrogen bottle valve is closed and connect the regulator to the nitrogen bottle.
Open the needle valve. Open the nitrogen bottle valve. Observe the pressure gauge on regulator (4) and open the regulator valve until some pressure is indicated on the regulator gauge. Then close the regulator valve.
Wait for 10 to 15 minutes to allow the temperature of the nitrogen gas to stabilize. Read the low-pressure gauge.For the correct pressure, refer to the engine Specifications manual.If the pressure is too low, repeat Steps 4 and 5 until the correct pressure is achieved.If the pressure is too high, perform Step 5.a through Step 5.c.
Close the needle valve and disconnect coupling (5).
Open the needle valve and then close the needle valve to purge some of the nitrogen gas from the accumulator.
Wait until the low-pressure gauge stabilizes. Read the gauge.Repeat Step 5.a through Step 5.c until the correct pressure is achieved.
Turn the chuck handle to close the gas valve. Open the needle valve to purge the nitrogen gas from the tooling.
Remove the tooling from the gas valve.
Close the nitrogen bottle valve. Remove the tooling from the nitrogen bottle.
Install the cap and the guard over the gas valve.
Note: The Tool Operating Manual, NEHS0742 is provided with the tool.
Illustration 1 g00995703
Assemble the following parts according to Tool Operating Manual, NEHS0742: nipple (1), needle valve (2), pipe tee (3), coupling (4), low-pressure gauge (5), chuck (6) and hose (7). Make sure that needle valve (2) is closed.
Illustration 2 g06316146
(8) Gas valve for the accumulator
Remove the guard and the cap to access the gas valve.
Connect chuck (6) to the gas valve. Turn the chuck handle to open the gas valve.
Wait until the low-pressure gauge stabilizes. Read the gauge.For the correct pressure, refer to the engine Specifications manual.If the pressure is correct, proceed to Step 5.If the pressure is too low, proceed to "Charging the Accumulator".
Turn the chuck handle to close the gas valve. Open needle valve (2) to purge the nitrogen gas from the tooling.
Remove the tooling from the gas valve. Install the cap and the guard over the gas valve.Charging the Accumulator
Note: Only use dry nitrogen gas to fill the accumulator.
Illustration 3 g00995724
Assemble the following parts according to Tool Operating Manual, NEHS0742: hose (1), nipple (2), coupling (3), regulator (4), and coupling (5). Connect coupling (5) to the nipple that is on the needle valve.
Crack the nitrogen bottle valve to purge any debris from the valve.
Make sure that regulator (4) is closed. Make sure that the nitrogen bottle valve is closed and connect the regulator to the nitrogen bottle.
Open the needle valve. Open the nitrogen bottle valve. Observe the pressure gauge on regulator (4) and open the regulator valve until some pressure is indicated on the regulator gauge. Then close the regulator valve.
Wait for 10 to 15 minutes to allow the temperature of the nitrogen gas to stabilize. Read the low-pressure gauge.For the correct pressure, refer to the engine Specifications manual.If the pressure is too low, repeat Steps 4 and 5 until the correct pressure is achieved.If the pressure is too high, perform Step 5.a through Step 5.c.
Close the needle valve and disconnect coupling (5).
Open the needle valve and then close the needle valve to purge some of the nitrogen gas from the accumulator.
Wait until the low-pressure gauge stabilizes. Read the gauge.Repeat Step 5.a through Step 5.c until the correct pressure is achieved.
Turn the chuck handle to close the gas valve. Open the needle valve to purge the nitrogen gas from the tooling.
Remove the tooling from the gas valve.
Close the nitrogen bottle valve. Remove the tooling from the nitrogen bottle.
Install the cap and the guard over the gas valve.
Parts screen EVINRUDE:
0312675
0312675 SCREEN,Filter
100193A, 100293R, 100882B, 100990S, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 25702H, 25802C, 25904R, 33002M, 33802M, 3390